Simple approach for the fabrication of screen-printed carbon-based electrode for amperometric detection on microchip electrophoresis

被引:27
|
作者
Petroni, Jacqueline Marques [1 ]
Lucca, Bruno Gabriel [2 ]
Ferreira, Valdir Souza [1 ]
机构
[1] Univ Fed Mato Grosso do Sul, Inst Quim, BR-79074460 Campo Grande, MS, Brazil
[2] Univ Fed Espirito Santo, Dept Ciencias Nat, BR-29932540 Sao Mateus, ES, Brazil
关键词
Electrochemical detection; Microfabrication; Microfluidic devices; PDMS microchips; Working electrode; FILM ELECTROCHEMICAL DETECTORS; REDUCED GRAPHENE OXIDE; ON-A-CHIP; CAPILLARY-ELECTROPHORESIS; COMPOSITE ELECTRODE; PALLADIUM DECOUPLER; CHANNEL; DEVICE; NITRITE; ELECTROPHORESIS/ELECTROCHEMISTRY;
D O I
10.1016/j.aca.2016.12.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a simple method for the fabrication of screen-printed based electrodes for amperometric detection on microchip electrophoresis (ME) devices. The procedure developed is quite simple and does not require expensive instrumentation or sophisticated protocols commonly employed on the production of amperometric sensors, such as photolithography or sputtering steps. The electrodes were fabricated through manual deposition of home-made conductive carbon ink over patterned acrylic substrate. Morphological structure and electrochemical behavior of the carbon electrodes were investigated by scanning electron microscopy and cyclic voltammetry. The produced amperometric sensors were coupled to polydimethylsiloxane (PDMS) microchips at end-channel configuration in order to evaluate their analytical performance. For this purpose, electrophoretic experiments were carried out using nitrite and ascorbic acid as model analytes. Separation of these substances was successfully performed within 50s with good resolution (R = 1.2) and sensitivities (713.5 pA/mu M for nitrite and 255.4 pA/ mu M for ascorbate). The reproducibility of the fabrication method was evaluated and revealed good values concerning the peak currents obtained (8.7% for nitrite and 9.3% for ascorbate). The electrodes obtained through this method exhibited satisfactory lifetime (ca. 400 runs) over low fabrication cost (less than $1 per piece). The feasibility of the proposed device for real analysis was demonstrated through the determination of nitrite concentration levels in drinking water samples. Based on the results achieved, the approach proposed here shows itself as an interesting alternative for simple fabrication of carbon-based electrodes. Furthermore, the devices indicate great promise for other kind of analytical applications involving ME devices. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:88 / 96
页数:9
相关论文
共 50 条
  • [1] Amperometric fructose sensor based on ferrocyanide modified screen-printed carbon electrode
    Biscay, Julien
    Costa Rama, Estefania
    Gonzalez Garcia, Maria Begona
    Julio Reviejo, A.
    Pingarron Carrazon, Jose Manuel
    Costa Garcia, Agustin
    [J]. TALANTA, 2012, 88 : 432 - 438
  • [2] The Detection of heavy metal ions based on screen-printed carbon electrode
    Liang, Fanghui
    Liu, Jin
    Zhang, Guanglei
    Kang, Yanqin
    [J]. SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, PTS 1-4, 2013, 303-306 : 891 - 895
  • [3] Fabrication of refreshable aptasensor based on hydrophobic screen-printed carbon electrode interface
    Fu, Jiayun
    Dong, Haowei
    Zhao, Qingxue
    Cheng, Shuting
    Guo, Yemin
    Sun, Xia
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 712
  • [4] Biocompatible carbon-based screen-printed electrodes for the electrochemical detection of nitric oxide
    Miserere, S
    Ledru, S
    Ruillé, N
    Griveau, S
    Boujtita, M
    Bedioui, F
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (02) : 238 - 244
  • [5] Simple and rapid electrochemical detection of 1-benzylpiperazine on carbon screen-printed electrode
    Rocha, G. Raquel
    Silva, C. O. F. Isabella
    Arantes, C. Luciano
    Stefano, S. Jessica
    Lima, D. Camila
    Melo, M. A. Larissa
    Munoz, A. A. Rodrigo
    dos Santos, T. P. Wallans
    Richter, M. Eduardo
    [J]. MICROCHEMICAL JOURNAL, 2021, 167
  • [6] An Amperometric Immunosensor for Microcystin-(Leucine-Arginine) Based on Screen-Printed Carbon Electrode
    Chen Xiang-Qiang
    He Miao
    Shi Han-Chang
    Cai Qiang
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (04) : 443 - 448
  • [7] Screen-Printed Contactless Conductivity Detector for Microchip Capillary Electrophoresis
    Wang, Joseph
    Chen, Gang
    Chatrathi, Madhu Prakash
    Wang, Mei
    Rinehart, Robert
    Muck, Alexander
    [J]. ELECTROANALYSIS, 2008, 20 (22) : 2416 - 2421
  • [8] Microchip capillary electrophoresis with a cellulose-DNA-modified screen-printed electrode for the analysis of neurotransmitters
    Johirul, M
    Shiddiky, A
    Kim, RE
    Shim, YB
    [J]. ELECTROPHORESIS, 2005, 26 (15) : 3043 - 3052
  • [9] A Simple Approach to Fabricate a Screen-Printed Electrode and Its Application for Uric Acid Detection
    Wahyuni, Wulan Tri
    Putra, Budi Riza
    Heryanto, Rudi
    Rohaeti, Eti
    Yanto, Dede Heri Yuli
    Fauzi, Achmad
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (02): : 1 - 14
  • [10] Porous screen-printed carbon electrode
    Niu, Xiangheng
    Chen, Chen
    Zhao, Hongli
    Tang, Jie
    Li, Yuxiu
    Lan, Minbo
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2012, 22 : 170 - 173