Experimental investigation on a novel arrangement of wet medium for evaporative cooling of air

被引:24
|
作者
Yan, Mingxuan [1 ]
He, Suoying [1 ]
Li, Na [2 ]
Huang, Xiang [3 ]
Gao, Ming [1 ]
Xu, Mengfei [1 ]
Miao, Jiayu [1 ]
Lu, Yuanshen [4 ]
Hooman, Kamel [4 ]
Che, Jianjun [5 ]
Geng, Zhe [6 ]
Zhang, Shuzhen [6 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Shandong Engn Lab High Efficiency Energy Conserva, Jinan 250061, Shandong, Peoples R China
[2] Shaanxi Univ Technol, Sch Mech Engn, Hanzhong 723001, Shaanxi, Peoples R China
[3] Xian Polytech Univ, Sch Urban Planning & Municipal Engn, Xian 710048, Shaanxi, Peoples R China
[4] Univ Queensland, Sch Mech & Min Engn, St Lucia, Qld 4072, Australia
[5] Jinan Cable Agr Biotechnol CO LTD, Jinan 251400, Shandong, Peoples R China
[6] Shandong Hetong Informat Technol CO LTD, Jinan 250013, Shandong, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Evaporative cooling; Wet medium; Novel arrangement; Wind tunnel test; WATER COLLECTING DEVICES; FLOW RESISTANCE; PERFORMANCE; SYSTEM; DESIGN; TOWER; CONDENSERS; PADS;
D O I
10.1016/j.ijrefrig.2020.12.014
中图分类号
O414.1 [热力学];
学科分类号
摘要
A low-speed wind tunnel was designed to experimentally study the cooling performance of a novel arrangement of wet medium for evaporative cooling of air. In the wet medium arrangement (CELdek7060), a 300 mm cooling section was formed by 100 mm wet medium + 100 mm gap + 100 mm wet medium, which will be denoted as 300 mm medium-gap-medium. Normal arrangement was experimentally studied for comparison with medium thicknesses of 100 and 300 mm, respectively. The result shows that the pressure drop of the 300 mm medium-gap-medium is lower than that of the normal medium at thicknesses of 300 mm and is close than that of 200 mm within the tested air speeds, and the cooling effectiveness of the 300 mm medium-gap-medium is higher than that of the normal medium at 200 mm but lower than that of the normal medium at 300 mm. Meanwhile, the correlations of pressure drop and heat transfer coefficient for the 300 mm medium-gap-medium are developed based on the test data. This study proves that the proposed 300 mm medium-gap-medium is feasible and shows superior performance when compared with normal medium at 200 mm thickness. (c) 2020 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:64 / 74
页数:11
相关论文
共 50 条
  • [1] Experimental investigation of air conditioning system using evaporative cooling condenser
    Wang, Tianwei
    Sheng, Chenguang
    Nnanna, A. G. Agwu
    [J]. ENERGY AND BUILDINGS, 2014, 81 : 435 - 443
  • [2] Numerical simulation of evaporative cooling process in a medium-gap-medium arrangement
    Zhang, Qi
    He, Suoying
    Cheng, Jun
    Zhao, Bin
    Wu, Xuehong
    Yan, Mingxuan
    Gao, Ming
    Geng, Zhe
    Zhang, Shuzhen
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 179
  • [3] An experimental investigation on the novel hybrid indirect direct evaporative cooling system
    Khan, Ibrahim
    Khalid, Waqas
    Ali, Hafiz Muhammad
    Sajid, Muhammad
    Ali, Zaib
    Ali, Majid
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 155
  • [4] Experimental investigation on the effect of nanobubbled water in evaporative cooling and oxygen enrichment in air cooler
    Senthilkumar, G.
    Rakesh, A. M.
    Krishna, B. R. S. Aravind Sri
    Joy, Nivin
    Ganesan, S.
    Hemanandh, J.
    [J]. MATERIALS TODAY-PROCEEDINGS, 2021, 44 : 3622 - 3626
  • [5] Enhancement of air conditioning system using direct evaporative cooling: Experimental and theoretical investigation
    Hashim, Rasha Hayder
    Hammdi, Salman Hashim
    Eidan, Adel A.
    [J]. OPEN ENGINEERING, 2023, 13 (01):
  • [6] Experimental investigation of using the evaporative air cooling technique to enhance the performance of the photovoltaic module
    Jaffar, Malik F.
    Mohammad, Abdulrahman Th
    Ahmed, Ahmed Qasim
    Al-Shohani, Wisam A. M.
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2024, 19 : 1231 - 1245
  • [7] Indirect evaporative cooling of air to a sub-wet bulb temperature
    Hasan, Ala
    [J]. APPLIED THERMAL ENGINEERING, 2010, 30 (16) : 2460 - 2468
  • [8] Experimental investigation of a novel configuration of desiccant based evaporative air conditioning system
    Uckan, Irfan
    Yilmaz, Tuncay
    Hurdogan, Ertac
    Buyukalaca, Orhan
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2013, 65 : 606 - 615
  • [9] ANALYTICAL AND EXPERIMENTAL INVESTIGATION OF ONE OF METHODS OF EVAPORATIVE COOLING
    LABUNTSO.DA
    KRASNOSH.AB
    [J]. THERMAL ENGINEERING, 1969, 16 (04) : 121 - &
  • [10] Experimental investigation of evaporative cooling systems for agricultural storage and livestock air-conditioning in Pakistan
    Raza, Hafiz M. U.
    Sultan, Muhammad
    Bahrami, Majid
    Khan, Alamgir A.
    [J]. BUILDING SIMULATION, 2021, 14 (03) : 617 - 631