Quantifying photovoltaic fire danger reduction with arc-fault circuit interrupters

被引:6
|
作者
Armijo, Kenneth M. [1 ]
Johnson, Jay [1 ]
Harrison, Richard K. [1 ]
Thomas, Kara E. [2 ]
Hibbs, Michael [1 ]
Fresquez, Armando [1 ]
机构
[1] Sandia Natl Labs, POB 5800, Albuquerque, NM 87185 USA
[2] George Washington Univ, Dept Chem, 725 21st St NWWA, Washington, DC 20052 USA
来源
PROGRESS IN PHOTOVOLTAICS | 2016年 / 24卷 / 04期
关键词
arc-fault; PV fire; characterization; modeling; spectroscopy; reliability; TEMPERATURE; AIR;
D O I
10.1002/pip.2561
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Unmitigated arc-faults present fire dangers, shock hazards, and cause system downtime in photovoltaic (PV) systems. The 2011 National Electrical Code (R) added section 690.11 to require a listed arc-fault protection device on new PV systems. Underwriters Laboratories created the outline of investigation for PV DC arc-fault circuit protection, UL 1699B, for certifying arc-fault circuit interrupters (AFCIs) for arc suppression. Unfortunately, little is known about appropriate trip times for arc-faults generated at different locations in the PV system, with different electrode and polymer encapsulant geometries and materials. In this investigation, a plasma model was developed, which determines fire danger with UL 1699B-listed AFCIs and consequences of arc-fault discharges sustained beyond UL 1699B trip time requirements. This model predicts temperatures for varying system configurations and was validated by 100 and 300W arc-faults experiments where combustion times and temperatures were measured. This investigation then extrapolated burn characteristics using this model to predict polymer ignition times for exposure to arc-power levels between 100 and 1200W. The numerical results indicate AFCI maximum trip times required by UL 1699B are sufficient to suppress 100-1200W arc-faults prior to fire initiation. Optical emission spectroscopy and thermochemical decomposition analysis were also conducted to assess spectral and chemical degradation of the polymer sheath. Published 2014. This article has been contributed to by US Government employees and their work is in the public domain in the USA.
引用
收藏
页码:507 / 516
页数:10
相关论文
共 21 条
  • [1] More about arc-fault circuit interrupters
    Gregory, GD
    Wong, K
    Dvorak, RF
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (04) : 1006 - 1011
  • [2] More about Arc-Fault Circuit Interrupters
    Gregory, GD
    Wong, K
    Dvorak, R
    [J]. 2003 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-3: CROSSROADS TO INNOVATIONS, 2003, : 1306 - 1313
  • [3] Demystification of Arc-Fault Circuit Interrupters: Part 2: Technology and Applications
    El-Sherif, Nehad
    Domitrovich, Thomas A.
    [J]. IEEE INDUSTRY APPLICATIONS MAGAZINE, 2024, 30 (04) : 14 - 26
  • [4] Demystification of Arc-Fault Circuit-Interrupters: Part I: Beginning of the Odyssey
    El-Sherif, Nehad
    Domitrovich, Thomas A.
    [J]. IEEE INDUSTRY APPLICATIONS MAGAZINE, 2024, 30 (03) : 18 - 27
  • [5] New Technology for Preventing Residential Electrical Fires: Arc-Fault Circuit Interrupters (AFCIs)
    Douglas A. Lee
    Andrew M. Trotta
    William H. King
    [J]. Fire Technology, 2000, 36 : 145 - 162
  • [6] New technology for preventing residential electrical fires: Arc-fault circuit interrupters (AFCIs)
    Lee, DA
    Trotta, AM
    King, WH
    [J]. FIRE TECHNOLOGY, 2000, 36 (03) : 145 - 162
  • [7] The arc-fault circuit protection
    Parise, G
    Martirano, L
    Grasselli, U
    Benetti, L
    [J]. CONFERENCE RECORD OF THE 2001 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2001, : 1817 - 1822
  • [8] The evolution of arc fault circuit interrupters
    Wafer, JA
    [J]. Proceedings of the Fifty-First IEEE Holm Conference on Electrical Contacts, 2005, : 156 - 161
  • [9] The arc-fault circuit interrupter: An emerging product
    Gregory, GD
    Scott, GW
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (05) : 928 - 933
  • [10] The arc-fault circuit interrupter, an emerging product
    Gregory, GD
    Scott, GW
    [J]. 1998 IEEE INDUSTRIAL & COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE - CONFERENCE RECORD, 1998, : 48 - 55