A bench study of intensive-care-unit ventilators: new versus old and turbine-based versus compressed gas-based ventilators

被引:82
|
作者
Thille, Arnaud W. [1 ,2 ,3 ]
Lyazidi, Aissam [1 ,2 ,3 ]
Richard, Jean-Christophe M. [4 ,5 ]
Galia, Fabrice [1 ,2 ,3 ]
Brochard, Laurent [1 ,2 ,3 ]
机构
[1] Hop Henri Mondor, Ctr Hosp Albert Chenevier, AP HP, Med Intens Care Unit, F-94010 Creteil, France
[2] Hop Henri Mondor, INSERM, Team 13, U955, F-94010 Creteil, France
[3] Univ Paris 12, Creteil, France
[4] Hop Univ Charles Nicolle, Med Intens Care Unit, Rouen, France
[5] UPRES EA3830, Rouen, France
关键词
Mechanical ventilation; Pressure-support ventilation; Work of breathing; Inspiratory trigger; Bench study; PRESSURE SUPPORT VENTILATION; INTERMITTENT MANDATORY VENTILATION; MECHANICAL VENTILATION; PERFORMANCE-CHARACTERISTICS; NONINVASIVE VENTILATION; ASSISTED VENTILATION; TRIGGERING SYSTEMS; ICU VENTILATORS; WORK; MODE;
D O I
10.1007/s00134-009-1467-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To compare 13 commercially available, new-generation, intensive-care-unit (ICU) ventilators in terms of trigger function, pressurization capacity during pressure-support ventilation (PSV), accuracy of pressure measurements, and expiratory resistance. Bench study at a research laboratory in a university hospital. Four turbine-based ventilators and nine conventional servo-valve compressed-gas ventilators were tested using a two-compartment lung model. Three levels of effort were simulated. Each ventilator was evaluated at four PSV levels (5, 10, 15, and 20 cm H(2)O), with and without positive end-expiratory pressure (5 cm H(2)O). Trigger function was assessed as the time from effort onset to detectable pressurization. Pressurization capacity was evaluated using the airway pressure-time product computed as the net area under the pressure-time curve over the first 0.3 s after inspiratory effort onset. Expiratory resistance was evaluated by measuring trapped volume in controlled ventilation. Significant differences were found across the ventilators, with a range of triggering delays from 42 to 88 ms for all conditions averaged (P < 0.001). Under difficult conditions, the triggering delay was longer than 100 ms and the pressurization was poor for five ventilators at PSV5 and three at PSV10, suggesting an inability to unload patient's effort. On average, turbine-based ventilators performed better than conventional ventilators, which showed no improvement compared to a bench comparison in 2000. Technical performance of trigger function, pressurization capacity, and expiratory resistance differs considerably across new-generation ICU ventilators. ICU ventilators seem to have reached a technical ceiling in recent years, and some ventilators still perform inadequately.
引用
收藏
页码:1368 / 1376
页数:9
相关论文
共 32 条
  • [1] A bench study of intensive-care-unit ventilators: new versus old and turbine-based versus compressed gas-based ventilators
    Arnaud W. Thille
    Aissam Lyazidi
    Jean-Christophe M. Richard
    Fabrice Galia
    Laurent Brochard
    [J]. Intensive Care Medicine, 2009, 35 : 1368 - 1376
  • [2] Assessment Of Turbine-Based Ventilators Used To Deliver Non-Invasive Ventilation: From Bench To Bedside
    Jolliet, P.
    Thevoz, D.
    Paratte, G.
    Verhoeven, J.
    Belmondo, B.
    Revelly, J. -P.
    Piquilloud, L.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [3] COMPARISON OF NONINVASIVE VENTILATION IN TWO TURBINE-BASED VENTILATORS DURING BILEVEL PRESSURE: SINGLE VERSUS (VS) DOUBLE CIRCUIT. A CLINICAL STUDY
    Serrano Simon, J. M.
    Munoz Guillen, N.
    Reyes Parras, M. P.
    Bautista Rodriguez, M. D.
    Rodriguez Perea, A.
    Paradas Torralvo, V.
    Leon-Lopez, R.
    Alcalde Mayayo, I.
    Guerrero Pabon, R.
    [J]. INTENSIVE CARE MEDICINE, 2010, 36 : S115 - S115
  • [4] Performance characteristics of five new anesthesia ventilators and four intensive care ventilators in pressure-support mode - A comparative bench study
    Jaber, Samir
    Tassaux, Didier
    Sebbane, Mustapha
    Pouzeratte, Yvan
    Battisti, Anne
    Capdevila, Xavier
    Eledjam, Jean-Jacques
    Jolliet, Philippe
    [J]. ANESTHESIOLOGY, 2006, 105 (05) : 944 - 952
  • [5] An Internet of Things-based Predictive Maintenance Architecture for Intensive Care Unit Ventilators
    Manchadi, Oumaima
    Ben-Bouazza, Fatima-Ezzahraa
    Dehbi, Zineb El Otmani
    Edder, Aymane
    Tafala, Idriss
    Et-Taoussi, Mehdi
    Jioudi, Bassma
    [J]. INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2024, 15 (02) : 932 - 943
  • [6] Effect of Jet Nebulization on Noninvasive Positive-Pressure Ventilation Administered with Noninvasive or Intensive Care Unit Ventilators: A Bench Study
    Xu, Meng-Jiao
    Dai, Bing
    Peng, Yun
    Su, Jia
    Tan, Wei
    Zhao, Hong-Wen
    [J]. RESPIRATION, 2019, 97 (04) : 355 - 362
  • [7] Usability Study of the User-Interface of Intensive Care Ventilators Based on User Test and Eye-Tracking Signals
    Jiang, Mingyin
    Liu, Shenglin
    Feng, Qingmin
    Gao, Jiaqi
    Zhang, Qiang
    [J]. MEDICAL SCIENCE MONITOR, 2018, 24 : 6617 - 6629
  • [8] Protocol-Based Care versus Individualized Management of Patients in the Intensive Care Unit
    Siner, Jonathan M.
    Connors, Geoffrey R.
    [J]. SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 36 (06) : 870 - 877
  • [9] Comparison of Ketamine- Versus Nonketamine-Based Sedation on Delirium and Coma in the Intensive Care Unit
    Shurtleff, Vanessa
    Radosevich, John J.
    Patanwala, Asad E.
    [J]. JOURNAL OF INTENSIVE CARE MEDICINE, 2020, 35 (06) : 536 - 541
  • [10] SEDATION DOSING BASED ON IDEAL BODY WEIGHT VERSUS TOTAL BODY WEIGHT IN THE INTENSIVE CARE UNIT
    Yeary, Julianne
    Greco, Alexandra
    Mcknight, Rich
    Petros, Karen
    Garavaglia, Jefferey
    [J]. CRITICAL CARE MEDICINE, 2018, 46 (01) : 476 - 476