Reliability, concurrent validity and minimal detectable change of the L test in patients with total knee arthroplasty

被引:11
|
作者
Yuksel, Ertugrul [1 ]
Eymir, Musa [2 ]
Unver, Bayram [2 ]
Karatosun, Vasfi [3 ]
机构
[1] Dokuz Eylul Univ, Grad Sch Hlth Sci, TR-35340 Izmir, Turkey
[2] Dokuz Eylul Univ, Sch Phys Therapy & Rehabil, Izmir, Turkey
[3] Dokuz Eylul Univ, Sch Med, Dept Orthoped & Traumatol, Izmir, Turkey
关键词
Functional performance; reliability; total knee arthroplasty; validity; balance; functional mobility;
D O I
10.1080/09638288.2021.1871670
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose The L test is a modified version of the timed up and go test (TUG), extending the walking distance from 6 to 20 meters and also requiring participants to make four turns in both (right/left) direction. It could be a useful measurement method in assessment of functional mobility for patients with Total Knee Arthroplasty (TKA). The aim of the study was to determine reliability, concurrent validity, and minimal detectable change (MDC) of L test in patients with TKA. Materials and methods The study included 43 patients with TKA. The Intraclass Correlation Coefficient (ICC) was used to assess the intra-rater reliability of the L test. The correlations of the L test with TUG were assessed for concurrent validity. Results Intra-rater (ICC 0.97) reliability of the L test was determined to be excellent. The SEM and MDC95 values of intra-rater reliability were 1.03 and 2.84, respectively. A high correlation was found between the L test and TUG (r: 0.75). Conclusion The L test is a valid and reliable method in the assessment of functional mobility in patients with TKA. The L test can be used to quantify changes in functional mobility level in patients with TKA. IMPLICATIONS FOR REHABILITATION The L test is a reliable and valid measurement tool that can be used to assess functional mobility in patients with TKA. Clinicians and researchers can use a greater change than 2.84 seconds for the L test as a meaningful change in patients with TKA.
引用
收藏
页码:3714 / 3718
页数:5
相关论文
共 50 条
  • [1] Reliability, validity, and minimal detectable change of the Step Test in patients with total knee arthroplasty
    Eymir, Musa
    Yuksel, Ertugrul
    Unver, Bayram
    Karatosun, Vasfi
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2022, 191 (06) : 2651 - 2656
  • [2] Reliability, validity, and minimal detectable change of the Step Test in patients with total knee arthroplasty
    Musa Eymir
    Ertugrul Yuksel
    Bayram Unver
    Vasfi Karatosun
    [J]. Irish Journal of Medical Science (1971 -), 2022, 191 : 2651 - 2656
  • [3] The test-retest reliability, concurrent validity, and minimal detectable change of the L test in patients with total hip arthroplasty
    Fatih Özden
    Gökhan Coşkun
    Serkan Bakırhan
    [J]. Bulletin of Faculty of Physical Therapy, 2021, 26 (1)
  • [4] Reliability, Concurrent Validity, and Minimal Detectable Change of the Hand-Held Dynamometry for the Assessment of Knee Muscle Strength in Patients With Revision Total Knee Arthroplasty
    Eymir, Musa
    Unver, Bayram
    Karatosun, Vasfi
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2024, 105 (01): : 34 - 39
  • [5] Reliability, Concurrent Validity, and Minimal Detectable Change for iPhone Goniometer App in Assessing Knee Range of Motion
    Mehta, Saurabh P.
    Barker, Katherine
    Bowman, Brett
    Galloway, Heather
    Oliashirazi, Nicole
    Oliashirazi, Ali
    [J]. JOURNAL OF KNEE SURGERY, 2017, 30 (06) : 577 - 584
  • [6] Reliability, Concurrent Validity, and Minimal Detectable Change of Timed Up and Go Obstacle Test in People With Stroke
    Ng, Shamay S. M.
    Tse, Mimi M. Y.
    Chen, Peiming
    Chan, Calvin K. H.
    Cheng, Eric H. Y.
    Iu, Kevin K. F.
    Wong, Thomson W. L.
    Liu, Tai-Wa
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2023, 104 (09): : 1465 - 1473
  • [7] Reliability and minimal detectable change of the 2-minute walk test and Timed Up and Go test in patients with total hip arthroplasty
    Yuksel, Ertugrul
    Unver, Bayram
    Kalkan, Serpil
    Karatosun, Vasfi
    [J]. HIP INTERNATIONAL, 2021, 31 (01) : 43 - 49
  • [8] Reliability, Concurrent Validity, and Minimal Detectable Change of a Smartphone Application for Measuring Thoracic Kyphosis
    Sahinoglu, Ertan
    Ergin, Gulbin
    Bakirhan, Serkan
    Unver, Bayram
    [J]. CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2023, 13 (03): : 511 - 516
  • [9] Reliability and validity of the two-minute step test in patients with total knee arthroplasty
    Akkan, Hakan
    Mutlu, Ebru Kaya
    Kuyubasi, Sabit Numan
    [J]. DISABILITY AND REHABILITATION, 2024, 46 (14) : 3128 - 3132
  • [10] RELIABILITY AND VALIDITY OF THE CONE EVASION WALK TEST IN PATIENTS WITH TOTAL KNEE ARTHROPLASTY: A PILOT STUDY
    Kacmaz, K. S.
    Unver, B.
    Karatosun, V.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2022, 81 : 1624 - 1624