Endobronchial coil spring fiducial markers for CyberKnife® stereotactic body radiation therapy

被引:10
|
作者
Casutt, Alessio [1 ]
Noirez, Leslie [1 ]
Bernasconi, Maurizio [2 ]
Koutsokera, Angela [1 ]
Beigelman-Aubry, Catherine [3 ]
Kinj, Remy [4 ]
Ozsahin, Esat-Mahmut [4 ]
Durham, Andre-Dante [4 ]
von Garnier, Christophe [1 ]
Lovis, Alban [1 ]
机构
[1] Univ Hosp Lausanne, Dept Pulmonol, CHUV, Rue Bugnon 21, CH-1011 Lausanne, Switzerland
[2] Osped San Giovanni Bellinzona, Dept Pulmonol, Bellinzona, Switzerland
[3] Univ Hosp Lausanne, Dept Radiodiagnost & Intervent Radiol, CHUV, Lausanne, Switzerland
[4] Univ Hosp Lausanne, Dept Radiat Oncol, CHUV, Lausanne, Switzerland
关键词
airway markers; bronchoscopy and interventional techniques; lung cancer; metallic fiducial marker; stereotactic body radiation therapy; LUNG; PLACEMENT; INSERTION; COMPLICATIONS; RADIOSURGERY; BRONCHOSCOPY; ULTRASOUND; GUIDANCE; TRACKING; SAFETY;
D O I
10.1111/resp.14006
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background and objective SBRT is an alternative treatment for early-stage inoperable lung cancer. Metallic FM allow to increase tumour tracking precision by CyberKnife (R). Currently used techniques for FM placement have many limitations; transthoracic insertion has a high risk for pneumothorax, endovascular insertion requires expertise and dedicated angiography infrastructure and endobronchial linear-gold FM dislocate frequently. This is the first study to assess the safety and efficacy of cs-FM endobronchial insertion under fluoroscopy with or without R-EBUS assessment. Methods We retrospectively evaluated all consecutive patients undergoing endobronchial cs-FM placement for at least one PPL <25 mm between 10.2015 and 12.2019. TBB of the PPL were performed in case of a typical R-EBUS signal. PPL tracking accuracy by CyberKnife, complications, cs-FM migration rate and procedure duration were analysed. Results A total of 52 patients were treated during 55 procedures and 207 cs-FM were placed in 70 PPL. Tracking was successful for 65 of 70 (93%) PPL. R-EBUS was performed for 33 (47%) PPL and TBB for 9 (13%) PPL. Bronchospasm occurred once and any other complications were observed. Migration of cs-FM occurred in 16 of 207 (8%) cs-FM. Migration was more frequent when the target was in a previously irradiated area (P = 0.022). The median bronchoscopy duration was 31.5 min (n = 48 procedures). Conclusion Bronchoscopic cs-FM placement is a rapid and safe procedure. It is associated with a low migration rate and allows precise SBRT delivery. Previous irradiation of the PPL was associated with a higher migration rate.
引用
收藏
页码:469 / 476
页数:8
相关论文
共 50 条
  • [1] Endobronchial microcoil fiducial markers for stereotactic radiation therapy
    Noirez, Leslie
    Casutt, Alessio
    Beigelman-Aubry, Catherine
    Bernasconi, Maurizio
    Kinj, Remy
    Durham, Andre-Dante
    Von Garnier, Christophe
    Lovis, Alban
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [2] Fiducial markers for stereotactic lung radiation therapy: review of the transthoracic, endovascular and endobronchial approaches
    Casutt, Alessio
    Kinj, Remy
    Ozsahin, Esat-Mahmut
    von Garnier, Christophe
    Lovis, Alban
    [J]. EUROPEAN RESPIRATORY REVIEW, 2022, 31 (163):
  • [3] Application of BioXmark® liquid fiducial markers for CyberKnife® stereotactic body radiotherapy
    Surkova, I.
    Boka, G.
    Mezeckis, M.
    Ledina, S.
    Buryk, V.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1395 - S1396
  • [4] Implantation of fiducial markers in the liver for stereotactic body radiation therapy: Feasibility and results
    Oldrini, G.
    Taste-George, H.
    Renard-Oldrini, S.
    Baumann, A. -S.
    Marchesi, V.
    Troufleau, P.
    Peiffert, D.
    Didot-Moisei, A.
    Boyer, B.
    Grignon, B.
    Henrot, P.
    [J]. DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2015, 96 (06) : 589 - 592
  • [5] CyberKnife® Robotic Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy
    Mintz, A.
    Heron, D. E.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (06) : 539 - 540
  • [6] Coil spring fiducial markers placed safely using navigation bronchoscopy in inoperable patients allows accurate delivery of CyberKnife stereotactic radiosurgery
    Schroeder, Carsten
    Hejal, Rana
    Linden, Philip A.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (05): : 1137 - 1142
  • [7] Fiducial Markers Allow Accurate and Reproducible Delivery of Liver Stereotactic Body Radiation Therapy
    Moskalenko, Marina
    Jones, Bernard L.
    Mueller, Adam
    Lewis, Shirley
    Shiao, Jay C.
    Zakem, Sara J.
    Robin, Tyler P.
    Goodman, Karyn A.
    [J]. CURRENT ONCOLOGY, 2023, 30 (05) : 5054 - 5061
  • [8] Endobronchial Fiducial to Guide Stereotactic Body Radiotherapy
    Shofer, Scott L.
    Dunphy, Frank
    Mahmood, Kamran
    Wahidi, Momen M.
    Yoo, David
    [J]. JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2013, 20 (03) : 274 - 275
  • [9] PLACEMENT OF FIDUCIAL MARKERS FOR RADIATION THERAPY VIA ENDOBRONCHIAL ULTRASOUND.
    Parks, Christopher
    Thompson, Patricia
    Bechara, Rabih
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2014, 9 (09) : S177 - S177
  • [10] The use of endobronchial ultrasound to place fiducial markers for targeted radiation therapy
    Parks, Christopher
    Thompson, Patricia L.
    Bechara, Rabih
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2014, 32 (15)