Simple Laboratory-made Piezoelectric Sensors for Detection of Selected Gaseous and/or Vapor Sample

被引:0
|
作者
Ruangchaiwat, Amnat [1 ,2 ]
Rannurags, Narabhats [1 ,2 ]
Phanichphant, Sukon [5 ]
Liawruangrath, Boonsom [3 ,4 ]
Liawruangrath, Saisunee [1 ,2 ,4 ]
机构
[1] Chiang Mai Univ, Fac Sci, Dept Chem, Alpha Flow Anal Grp, Chiang Mai 50200, Thailand
[2] Chiang Mai Univ, Fac Sci, Mat Sci Res Ctr, Ctr Excellence Innovat Chem PERCH CIC, Chiang Mai 50200, Thailand
[3] Chiang Mai Univ, Dept Pharmaceut Sci, Fac Pharm, Chiang Mai 50200, Thailand
[4] Chiang Mai Univ, Sci & Technol Res Inst, Chiang Mai 50200, Thailand
[5] Chiang Mai Univ, Mat Sci Res Ctr, Fac Sci, Chiang Mai 50200, Thailand
来源
CHIANG MAI JOURNAL OF SCIENCE | 2016年 / 43卷 / 04期
关键词
piezoelectric; PZT sensors; methanol; sulphur dioxide; SULFUR-DIOXIDE; QUARTZ-CRYSTAL; DESIGN;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A very simple laboratory made prototype piezoelectric transducer (PZT) or sensor is described using inexpensive materials and equipment easily available in Chiang Mai and in the laboratory. Initially, experiments are carried out using a single cell device constructed in this laboratory afterwards a double-cell device is modified from the prototype device for measuring gaseous/vapour contaminants in air. The PZT detectors were tested for detection of SO2 on the basis of the best known SO2 detection using triethanolamine as coating material. It was found that the dual-cell device was more sensitive to SO2 (48 Hz ppm) than the single-cell one (6 Hz/ppm). Optimal conditions for the PZT detector were also investigated. The AT-cut quartz crystals with circular shape having thin film gold electrodes on both sides were employed. It was shown that the 10 MHz crytal coated with triethanolamine was more sentitive than the 6 MHz quartz crystal and hence the 10 MHz quartz crystal was selected as optimum. Selectivity of the PZT detector can be achieved by changing the coating materials. Under suitable conditions, choice of appropriate coating materials could be achieved for a number gaseous/vapour samples. The proposed PZT sensors using selective coatings were successfully applied for detection of SO2 and methanol with satisfactory results.
引用
收藏
页码:783 / 793
页数:11
相关论文
共 16 条
  • [1] A SIMPLE LABORATORY-MADE TURBIDIMETER
    NYBOM, N
    [J]. PHYSIOLOGIA PLANTARUM, 1959, 12 (01) : 173 - &
  • [2] Laboratory-made electrochemical sensors for adsorptive stripping voltammetry
    Goscinska, T
    [J]. JOURNAL OF CHEMICAL EDUCATION, 1998, 75 (08) : 1038 - 1039
  • [3] A laboratory-made capillary electrophoresis equipment with conductometric detection
    Bockel, Wolmir J.
    Martini, Emilse M. A.
    Samios, Dimitrios
    Piatnicki, Clarisse M. S.
    [J]. QUIMICA NOVA, 2005, 28 (06): : 1106 - 1110
  • [4] Selected properties of laboratory-made laminated-bamboo lumber
    Lee, AWC
    Bai, XS
    Bangi, AP
    [J]. HOLZFORSCHUNG, 1998, 52 (02) : 207 - 210
  • [5] Detection of Bacteria Based on Quantum Dots by Using a Laboratory-Made System
    CHENG Zhi
    WU Tai-hu
    CHEN Feng
    DU Yao-hua
    GU Biao
    LI Chao
    YANG Zi-jian
    [J]. Chinese Journal of Biomedical Engineering, 2018, 27 (01) : 40 - 46
  • [6] Simplified Pressure-Controlled Sample Introduction into Separation Capillary in Laboratory-Made Electrophoretic Apparatus
    Kadlecova, Tereza
    Opekar, Frantisek
    Tuma, Petr
    [J]. XXXIII MODERNI ELEKTROCHEMICKE METODY, 2013, : 88 - 91
  • [7] Structural Properties and Simple Compression Behavior of Laboratory-Made Polycrystalline Isotropic Ice at High Temperatures
    Seifaddini, M.
    Aryanpour, G.
    Farzaneh, M.
    [J]. JOURNAL OF OFFSHORE MECHANICS AND ARCTIC ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (01):
  • [8] Simple laboratory-made system for the determination of C-2-C-7 hydrocarbons relevant to photochemical smog pollution
    Ciccioli, P
    Brancaleoni, E
    Mabilia, R
    Cecinato, A
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1997, 777 (02) : 267 - 274
  • [9] Simple laboratory-made automated sequential injection analysis (SIA) device.: 1.: Design and testing of the hardware component
    Solich, P
    Svoboda, A
    Sklenárova, H
    Polasek, M
    Karlícek, R
    [J]. INSTRUMENTATION SCIENCE & TECHNOLOGY, 2002, 30 (01) : 13 - 20
  • [10] Simple molecule-based fluorescent sensors for vapor detection of TNT
    Zyryanov, Grigory V.
    Palacios, Manuel A.
    Anzenbacher, Pavel, Jr.
    [J]. ORGANIC LETTERS, 2008, 10 (17) : 3681 - 3684