Detecting Grouting Quality of Tendon Ducts Using the Impact-Echo Method

被引:1
|
作者
Qu, Guangzhen [1 ,2 ]
Sun, Min [3 ]
Zhou, Guangli [2 ]
机构
[1] Changan Univ, Sch Highway, Xian 710064, Shaanxi, Peoples R China
[2] Shandong Transportat Inst, Jinan 250031, Shandong, Peoples R China
[3] Shandong Highway Technician Coll, Jinan 250104, Shandong, Peoples R China
关键词
D O I
10.1063/1.5041395
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The performance, durability and safety of prestressed concrete bridge were directly affected by the compaction of prestressed pipe. However, the pipe was hidden in the beam, and its grouting density was difficult to detect. The paper had modified three different status of gouting quality through making test model. After that, the impact-Echo method was adopted to detect the grouting quality of tendon ducts, the study was sunmmarized as follow. If the reflect time of slab bottom and nominal thickness of slab increased, the degree of density will increase; testing from half-hole of web, the reflect time and nominal thickness of slab was biggest. At the same time, the reflect time of compacted and uncompacted tendon ducts were mainly. At last, the method was verified by the engineering project, which provided reference value.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] INSPECTING THE INJECTION QUALITY OF GROUTED TENDON DUCTS WITH IMPACT-ECHO METHOD
    Wang, Zhi-Feng
    Zhou, Xian-Yan
    Yan, Ban-Fu
    [J]. 4TH INTERNATIONAL SYMPOSIUM ON LIFETIME ENGINEERING OF CIVIL INFRASTRUCTURE, 2009, : 228 - 233
  • [2] Detecting voids in grouted tendon ducts of post-tensioned concrete structures using the impact-echo method
    Jaeger, BJ
    Sansalone, MJ
    Poston, RW
    [J]. ACI STRUCTURAL JOURNAL, 1996, 93 (04) : 462 - 473
  • [3] Experimental and Numerical Studies on Nondestructive Evaluation of Grout Quality in Tendon Ducts Using Impact-Echo Method
    Zou, Chunjiang
    Chen, Zhengzhou
    Dong, Ping
    Chen, Changhe
    Cheng, Yi
    [J]. JOURNAL OF BRIDGE ENGINEERING, 2016, 21 (02)
  • [4] Application of Impact-Echo Method in Grouting Inspection in Ducts inside Prefabricated Box Girder
    Kong, Cunzhi
    Xu, Xiangfeng
    Sun, Jialong
    Qi, Guangzhi
    Cao, Yuan
    [J]. ADVANCES IN TRANSPORTATION, PTS 1 AND 2, 2014, 505-506 : 24 - +
  • [5] DETECTION OF VOIDS IN GROUTED DUCTS USING THE IMPACT-ECHO METHOD
    CARINO, NJ
    SANSALONE, M
    [J]. ACI MATERIALS JOURNAL, 1992, 89 (03) : 296 - 303
  • [6] Evaluation of grouted tendon ducts of an existing post-tensioned bridge using the impact-echo method
    Jaeger, BJ
    [J]. 13TH ANNUAL INTERNATIONAL BRIDGE CONFERENCE AND EXHIBITION, OFFICIAL PROCEEDINGS, 1996, : 353 - 359
  • [7] Development of Grouting Quality Evaluation System for a Shield TBM Tunnel Using the Impact-Echo Method
    Sung, Wonsuh
    Song, Ki-Il
    Kim, Kyoung-Yul
    Ryu, Hee-Hwan
    [J]. KSCE JOURNAL OF CIVIL ENGINEERING, 2024,
  • [8] Impact-echo thickness frequency profiles for detection of voids in tendon ducts
    Abraham, O
    Côte, P
    [J]. ACI STRUCTURAL JOURNAL, 2002, 99 (03) : 239 - 247
  • [9] Detecting flaws in concrete blocks using the impact-echo method
    Hsiao, Chiamen
    Cheng, Chia-Chi
    Liou, Tzunghao
    Juang, Yuanting
    [J]. NDT & E INTERNATIONAL, 2008, 41 (02) : 98 - 107
  • [10] Evaluation of grouting in tunnel lining using impact-echo
    Aggelis, D. G.
    Shiotani, T.
    Kasai, K.
    [J]. TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2008, 23 (06) : 629 - 637