Evaluation of Clip Artefacts in Three-dimensional Computed Tomography

被引:17
|
作者
Pechlivanis, I.
Koenig, M.
Engelhardt, M.
Scholz, M.
Heuser, L.
Harders, A.
Schmieder, K.
机构
[1] Ruhr Univ Bochum, Dept Neurosurg, D-44892 Bochum, Germany
[2] Ruhr Univ Bochum, Dept Radiol, D-44892 Bochum, Germany
来源
CENTRAL EUROPEAN NEUROSURGERY | 2009年 / 70卷 / 01期
关键词
3D-CTA; titanium clips; artifacts; TITANIUM ANEURYSM CLIPS; DIGITAL-SUBTRACTION-ANGIOGRAPHY; INTRACRANIAL ANEURYSMS; CEREBRAL ANEURYSMS; CT ANGIOGRAPHY;
D O I
10.1055/s-0028-1082055
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Recently, three-dimensional CT angiography (3D-CTA) has been used as a diagnostic method in postoperative evaluation after aneurysm clipping. A systematic analysis of possible predictors for good image quality needs to be conducted if 3D-CTA is to replace digital subtraction angiography in the postoperative setting. The aim of this study was to evaluate the influence of clip orientation on image quality and to assess titanium clip artefacts quantitatively on 3D-CTA. Material and Method: Four different Yasargil titanium clips were placed on an acrylic glass tablet. Standardised 3D-CTA scanning was performed at clip-gantry angles of 0, 45 and 90. Multiplanar reconstructions of the clips in frontal and lateral projections were performed. 3D-CTA image quality and the severity of titanium artefacts were judged by four observers. Results: Twenty-four images were evaluated. Using frontal reconstructions, clip artefacts at a clip-gantry angle of 0 were almost exclusively distributed along the long axis of the clip, with excellent evaluation quality at the lateral side of the clip branches. With decreasing clip-gantry angle (90 and 45) strong artefacts were localised laterally. On lateral reconstructions image quality was not significantly more restricted, regardless of the clip-gantry angles used. Conclusion: 3D-CTA image quality can be severely limited by clip artefacts. The expression and distribution of these artefacts depends on both the clip-gantry angle and the plane of image reconstruction. Overall, there is no correlation between clip-gantry angle and either the severity or the spatial distribution of clip artefacts leading to observable restrictions in the evaluation of surrounding structures.
引用
收藏
页码:9 / 14
页数:6
相关论文
共 50 条
  • [1] Evaluation of styloid process by three-dimensional computed tomography
    C. Çınar Başekim
    Hakan Mutlu
    Atila Güngör
    Emir Şilit
    Zekai Pekkafali
    Murat Kutlay
    Ahmet Çolak
    Ersin Öztürk
    Eşref Kizilkaya
    [J]. European Radiology, 2005, 15 : 134 - 139
  • [2] Evaluation of styloid process by three-dimensional computed tomography
    Basekim, CÇ
    Mutlu, H
    Güngör, A
    Silit, E
    Pekkafali, Z
    Kutlay, M
    Çolak, A
    Öztürk, E
    Kizilkaya, E
    [J]. EUROPEAN RADIOLOGY, 2005, 15 (01) : 134 - 139
  • [3] Development of a three-dimensional dose evaluation method for computed tomography
    Katsuda, Toshizo
    Gotanda, Rumi
    Gotanda, Tatsuhiro
    Kuwano, Tadao
    Tanki, Nobuyoshi
    Yabunaka, Kouichi
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (02):
  • [4] Three-dimensional computed tomography in evaluation of ankylosis of the temporomandibular joint
    Görgü, M
    Erdogan, B
    Aköz, T
    Kosar, U
    Dag, F
    [J]. SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2000, 34 (02): : 117 - 120
  • [5] Evaluation of an ossifying fibroma using three-dimensional computed tomography
    Cavalcanti, MGP
    Ruprecht, A
    Vannier, MW
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (06) : 342 - 345
  • [6] Three-dimensional pelvimetry by computed tomography
    Lenhard, M.
    Johnson, T.
    Weckbach, S.
    Nikolaou, K.
    Friese, K.
    Hasbargen, U.
    [J]. RADIOLOGIA MEDICA, 2009, 114 (05): : 827 - 834
  • [7] Three-dimensional evaluation of the posterior airway space: differences in computed tomography and cone beam computed tomography
    Nassim Ayoub
    Philipp Eble
    Kristian Kniha
    Florian Peters
    Stephan Christian Möhlhenrich
    Evgeny Goloborodko
    Frank Hölzle
    Ali Modabber
    [J]. Clinical Oral Investigations, 2019, 23 : 603 - 609
  • [8] Three-dimensional evaluation of the posterior airway space: differences in computed tomography and cone beam computed tomography
    Ayoub, Nassim
    Eble, Philipp
    Kniha, Kristian
    Peters, Florian
    Moehlhenrich, Stephan Christian
    Goloborodko, Evgeny
    Hoelzle, Frank
    Modabber, Ali
    [J]. CLINICAL ORAL INVESTIGATIONS, 2019, 23 (02) : 603 - 609
  • [9] Evaluation of oesophageal atresia without fistula by three-dimensional computed tomography
    Luo, CC
    Lin, JN
    Wang, CR
    [J]. EUROPEAN JOURNAL OF PEDIATRICS, 2002, 161 (11) : 578 - 580
  • [10] Three-dimensional evaluation of craniofacial asymmetry: an analysis using computed tomography
    Rosa María Yáñez-Vico
    Alejandro Iglesias-Linares
    Daniel Torres-Lagares
    José Luis Gutiérrez-Pérez
    Enrique Solano-Reina
    [J]. Clinical Oral Investigations, 2011, 15 : 729 - 736