Comparative evaluation of risk of a split air conditioner and refrigerator using hydrocarbon refrigerants

被引:26
|
作者
Colbourne, D. [1 ]
Suen, K. O. [2 ]
机构
[1] Rephridge, Stratford Upon Avon CV37 1FE, Warwick, England
[2] UCL, London WC1E 6BT, England
关键词
Hydrocarbon refrigerant; R290; R600a; Air conditioner; Domestic refrigerator; Risk assessment; FLAMMABILITY HAZARDS;
D O I
10.1016/j.ijrefrig.2015.06.026
中图分类号
O414.1 [热力学];
学科分类号
摘要
The use of flammable refrigerants, such as R290 (propane), as an alternative to HCFC R22 in room split air conditioners (SACs) is being pursued. Concerns exist that current experience for safe application of R290 SACs is minimal. Conversely, there is extensive application of domestic and small commercial hydrocarbon refrigeration systems; this experience can help determine safety implications to wider use of R290 SACs. This study uses established quantitative risk assessment methods to estimate frequency and severity of ignition of R600a domestic refrigerators, which corresponds to current experience. The methodologies are also applied to R290 SACs based on their particular characteristics to estimate the associated risk. Results show the frequency and severity of ignition of SACs are significantly lower than domestic refrigerators due to the SAC installation characteristics being more conducive for dispersion of leaked refrigerant and less potential for confinement of a flammable mixture in the event of ignition. (C) 2015 Elsevier Ltd and International Institute of Refrigeration. All rights reserved.
引用
收藏
页码:295 / 303
页数:9
相关论文
共 50 条
  • [1] COMPARATIVE RISK ASSESSMENT OF HYDROCARBON REFRIGERANT IN A REFRIGERATOR AND SPLIT AIR CONDITIONER
    Colbourne, D.
    [J]. 11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 118 - 125
  • [2] Retrofit assessment of refrigerator using hydrocarbon refrigerants
    Yu, Chao-Chieh
    Teng, Tun-Ping
    [J]. APPLIED THERMAL ENGINEERING, 2014, 66 (1-2) : 507 - 518
  • [3] Performance evaluation of hydrocarbon and its blend in split packaged inverter operated air conditioner
    Mali, Kundlik V.
    Utage, Ashish S.
    Phadake, Heramb C.
    [J]. MATERIALS TODAY-PROCEEDINGS, 2021, 47 : 5589 - 5593
  • [4] Insurance risk for hydrocarbon refrigerants in car air-conditioners
    McLaineCross, IL
    [J]. REFRIGERATION, CLIMATE CONTROL AND ENERGY CONSERVATION, 1996, : 262 - 271
  • [5] Evaluation of Alternative Refrigerants for Mini-Split Air Conditioners
    Abdelaziz, Omar
    Shrestha, Som S.
    [J]. ASHRAE TRANSACTIONS 2017, VOL 123, PT 1, 2017, 123 : 147 - 161
  • [6] Exergetic performance analysis of low GWP refrigerants as an alternative to R410A in split air conditioner
    Mishra, Punit
    Soni, Shubham
    Maheshwari, Govind
    [J]. MATERIALS TODAY-PROCEEDINGS, 2022, 63 : 406 - 412
  • [7] Study of the explosion characteristics and combustion products of air conditioner using flammable refrigerants
    Zhang, Wang
    Yang, Zhao
    Li, Jin
    Ren, Chang-xing
    Lv, Dong
    [J]. JOURNAL OF FIRE SCIENCES, 2015, 33 (05) : 405 - 424
  • [8] Retrofit assessment of automobile air conditioners using hydrocarbon refrigerants
    Hsieh, Hsiang-Kai
    Teng, Tun-Ping
    [J]. Applied Thermal Engineering, 2022, 214
  • [9] Performance improvement of a split air conditioner by using an energy saving device
    Chen, Wei-Han
    Mo, Huai-En
    Teng, Tun-Ping
    [J]. ENERGY AND BUILDINGS, 2018, 174 : 380 - 387
  • [10] Energy Enhancement of Air Conditioner Using R32 and R290 Refrigerants
    Giriprasath, B. S.
    Chandramohan, R.
    Kumar, R. Ajith
    Arun, N. K.
    [J]. 3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN AEROMECHANICAL MATERIALS FOR MANUFACTURING: ICAAMM-2020, 2021, 2317