Unexpected reactions of the anti-IgA antibody particle gel immunoassay

被引:1
|
作者
Strobel, E. [1 ]
von Meyer, A. [2 ]
机构
[1] Stadt Klinikum Munchen GmbH, Dept Mikrobiol, Medizet, D-80804 Munich, Germany
[2] Stadt Klinikum Munchen GmbH, Dept Klin Chem, Medizet, D-80804 Munich, Germany
关键词
allergy; anti-IgA antibody; IgA-deficiency; particle gel immunoassay; transfusion reaction; ANAPHYLACTIC TRANSFUSION REACTIONS; RAPID DETECTION;
D O I
10.1111/tme.12094
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe cause of allergic transfusion reactions remains often unknown, but in rare cases anti-immunoglobulin A (IgA) antibodies in patients with IgA-deficiency can be found. We report on the use of the DiaMed particle gel immunoassay (PaGIA) for detection of anti-IgA antibodies in patients with allergic transfusion reactions. MethodsThe examination of the suspected adverse reactions included an anti-IgA antibody test (ID-PaGIA Anti-IgA antibody test; DiaMed GmbH, Cressier , Switzerland) and measurement of IgA concentration in the patient's plasma. In the case of a discrepancy IgA subclasses were examined and neutralization of the anti-IgA antibodies by pure IgA was performed. ResultsOf 142 patients tested for IgA concentration and anti-IgA antibodies, 8 gave positive results for the anti-IgA antibody test. In seven of these cases (4.9% of the patients tested) IgA levels were found to be normal, and in four of five so tested, the positive result could not be neutralized with purified IgA. Only one patient had confirmed IgA deficiency with anti-IgA antibodies that were neutralized by addition of purified IgA. ConclusionCause and clinical relevance of a positive reaction of the anti-IgA antibody test in patients with normal total IgA and normal IgA subclasses remains unknown. Because of the high false positive rate we do not recommend this test as a screening test for anti-IgA antibodies when evaluating allergic transfusion reactions, but instead recommend measurement of total IgA in patient's plasma or serum as a primary screen for IgA deficiency with antibodies as a cause of allergic transfusion reaction.
引用
收藏
页码:55 / 57
页数:3
相关论文
共 50 条
  • [1] Anti-IgA detection by particle gel immunoassay
    Palmer, Douglas S.
    [J]. BLOOD TRANSFUSION, 2014, 12 (03) : 291 - 292
  • [2] ANAPHYLACTOID TRANSFUSION REACTIONS CAUSED BY ANTI-IGA ANTIBODY
    VYAS, GN
    PERKINS, HA
    FUDENBERG, HH
    [J]. TRANSFUSION, 1968, 8 (05) : 309 - +
  • [3] ANAPHYLACTIC TRANSFUSION REACTIONS ASSOCIATED WITH ANTI-IGA ANTIBODY
    SCHMIDT, AP
    TASWELL, HF
    GLEICH, GJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1969, 280 (04): : 188 - &
  • [4] Detection of anti-IgA antibodies using the particle gel immunoassay: a rapid test for increased patient safety
    Oltean, Simona
    Epure, Andreea
    Lindstrom, Karin
    Pardi, Cecilia
    [J]. BLOOD TRANSFUSION, 2014, 12 (03) : 334 - 339
  • [5] SERUM IGA CLASS ANTI-IGA ANTIBODY IN IGA NEPHROPATHY
    HIKI, Y
    SAITOH, M
    KOBAYASHI, Y
    [J]. NEPHRON, 1991, 59 (04): : 552 - 560
  • [6] ANAPHYLACTIC TRANSFUSION REACTIONS AND ANTI-IGA
    RIVAT, L
    RIVAT, C
    DAVEAU, M
    ROPARTZ, C
    [J]. EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1973, 3 (03) : 265 - 265
  • [7] Evaluation of two particle gel immunoassays for detecting IgA immunoglobulin deficiency and anti-IgA antibodies
    Barea, L.
    Gonzalez, R.
    Cerezo, B.
    Vinuesa, P.
    Castro, E.
    [J]. TRANSFUSION, 2007, 47 (03) : 112A - 112A
  • [8] Evaluation of the DiaMed IgA and Anti-IgA Gel Card Assays
    Henry, M.
    Bombard, S.
    Riley, K.
    Roman, B.
    Demcoe, J.
    Nance, S. J.
    Wylie, D.
    [J]. TRANSFUSION, 2009, 49 : 186A - 186A
  • [9] ANTI-IGA ANTIBODIES AND TRANSFUSION REACTIONS IN CANADA
    LASCHINGER, CA
    NAYLOR, DH
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 1983, 128 (04) : 381 - 382
  • [10] ANAPHYLACTOID TRANSFUSION REACTIONS ASSOCIATED WITH ANTI-IGA
    VYAS, GN
    PERKINS, HA
    FUDENBERG, HH
    [J]. LANCET, 1968, 2 (7563): : 312 - +