Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction (vol 38, pg 1421, 2018)

被引:4
|
作者
Nagayama, Yasunori
Oda, Seitaro
Nakaura, Takeshi
Tsuji, Akinori
Urata, Joji
Furusawa, Mitsuhiro
Utsunomiya, Daisuke
Funama, Yoshinori
Kidoh, Masafumi
Yamashita, Yasuyuki
机构
关键词
D O I
10.1148/rg.2019194005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:912 / 912
页数:1
相关论文
共 50 条
  • [1] Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction
    Nagayama, Yasunori
    Oda, Seitaro
    Nakaura, Takeshi
    Tsuji, Akinori
    Urata, Joji
    Furusawa, Mitsuhiro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Kidoh, Masafumi
    Yamashita, Yasuyuki
    [J]. RADIOGRAPHICS, 2018, 38 (05) : 1421 - +
  • [2] Reducing the Radiation Dose for CT Colonography: Effect of Low Tube Voltage and Iterative Reconstruction
    Yamamura, Sadahiro
    Oda, Seitaro
    Imuta, Masanori
    Utsunomiya, Daisuke
    Yoshida, Morikatsu
    Namimoto, Tomohiro
    Yuki, Hideaki
    Kidoh, Masafumi
    Funama, Yoshinori
    Baba, Hideo
    Yamashita, Yasuyuki
    [J]. ACADEMIC RADIOLOGY, 2016, 23 (02) : 155 - 162
  • [3] Radiation Dose Reduction with Hybrid Iterative Reconstruction for Pediatric CT
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Shenoy-Bhangle, Anuradha S.
    Saini, Aashna
    Gervais, Debra A.
    Westra, Sjirk J.
    Thrall, James H.
    [J]. RADIOLOGY, 2012, 263 (02) : 537 - 546
  • [4] Successful Dose Reduction Using Reduced Tube Voltage With Hybrid Iterative Reconstruction in Pediatric Abdominal CT
    Berlin, Sheila C.
    Weinert, Dayna M.
    Vasavada, Pauravi S.
    Martinez-Rios, Claudia
    Parikh, Roshni A.
    Wien, Michael A.
    Jordan, David W.
    Novak, Ronald D.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (02) : 392 - 399
  • [5] Synergistic Radiation Dose Reduction by Combining Automatic Tube Voltage Selection and Iterative Reconstruction
    Wortman, Jeremy R.
    Adduci, Alexander J.
    Sodickson, Aaron D.
    [J]. JOURNAL OF THORACIC IMAGING, 2016, 31 (02) : 111 - 118
  • [6] Feasibility Study of Radiation Dose Reduction in Adult Female Pelvic CT Scan with Low Tube-Voltage and Adaptive Statistical Iterative Reconstruction
    Wang, Xinlian
    He, Wen
    Chen, Jianghong
    Hu, Zhihai
    Zhao, Liqin
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (05) : 1047 - 1055
  • [7] The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography Effects on image quality and radiation dose
    Feng, Cui
    Zhu, Di
    Zou, Xianlun
    Li, Anqin
    Hu, Xuemei
    Li, Zhen
    Hu, Daoyu
    [J]. MEDICINE, 2018, 97 (12)
  • [8] Low-dose abdominal CT: Comparison of low tube voltage with moderate-level iterative reconstruction and standard tube voltage, low tube current with high-level iterative reconstruction
    Kidoh, M.
    Nakaura, T.
    Nakamura, S.
    Oda, S.
    Utsunomiya, D.
    Sakai, Y.
    Harada, K.
    Yamashita, Y.
    [J]. CLINICAL RADIOLOGY, 2013, 68 (10) : 1008 - 1015
  • [9] Radiation Dose Reduction via Sinogram Affirmed Iterative Reconstruction and Automatic Tube Voltage Modulation (CARE kV) in Abdominal CT
    Shin, Hyun Joo
    Chung, Yong Eun
    Lee, Young Han
    Choi, Jin-Young
    Park, Mi-Suk
    Kim, Myeong-Jin
    Kim, Ki Whang
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2013, 14 (06) : 886 - 893
  • [10] Radiation dose reduction and image quality in pediatric paranasal sinus CT: with automatic tube current modulation and iterative reconstruction technique
    Chen, Xiao-Fang
    Zhang, Yi-Chi
    Ding, Ning
    Liu, Li
    Ji, Yi-Ding
    Zhang, Chao
    Chi, Jing
    [J]. RADIATION PROTECTION DOSIMETRY, 2024, 200 (15) : 1470 - 1476