Continuous bed motion data processing for a high resolution LSO PET/CT scanner

被引:0
|
作者
Burbar, Z. [1 ]
Michel, C. [1 ]
Towsend, D. [1 ]
Jakoby, B. [1 ]
Sibomana, M. [1 ]
Kehren, F. [1 ]
Tolbert, S. [1 ]
Reed, J. [1 ]
Hubner, K. [1 ]
Abidi, M. [1 ]
机构
[1] CPS Innovat, Knoxville, TN USA
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Continuous whole-body PET scanning, Continuous Bed Motion (CBM) acquisition has a number of advantages over the traditional Step-and-Shoot (SS) mode. Strengths of CBM include a uniform axial signal-to-noise ratio, continuous sampling in the axial direction that reduces resolution artifacts, reduction of noise from detector normalization, and reduction of sensitivity to small patient movements. This work highlights the acquisition and data handling methodology that was implemented for a series of phantoms and over 40 patient studies acquired on a high resolution, 16-slice LSO combined PET/CT scanner (CPS Innovations, Knoxville, TN). CBM data were acquired in 32-bit listmode with the bed moving at a constant speed of typically 0.6 mm/s to match the acquisition time per plane of the SS mode. CBM data were processed using the novel, virtual scanner concept that can be applied to a scanner of any axial length. For the high resolution scanner, the LSO PET detectors are arranged in a truncated spherical geometry and therefore normalization and geometrical corrections are applied on an event-by-event basis during histogramming of the 32-bit listmode data. Scatter correction is calculated on the entire image volume, in contrast to the SS mode where scatter is estimated for each bed position. The final 3D data set was reconstructed using Ordinary Poisson OSEM3D. This paper will present results from phantom studies and compare clinical patient scans acquired in both SS and CBM modes.
引用
收藏
页码:2046 / 2048
页数:3
相关论文
共 50 条
  • [1] Continuous bed motion acquisition for an LSO PET/CT scanner
    Townsend, DW
    Reed, J
    Newport, DF
    Carney, JPJ
    Tolbert, S
    Newby, D
    Yap, JT
    Long, MJ
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2383 - 2387
  • [2] Studies with a prototype high resolution PET scanner based on LSO-APD modules
    Pichler, B
    Boning, G
    Lorenz, E
    Mirzoyan, R
    Pimpl, W
    Schwaiger, M
    Ziegler, SI
    [J]. 1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1649 - 1653
  • [3] Studies with a prototype high resolution PET scanner based on LSO-APD modules
    Pichler, B
    Boning, G
    Lorenz, E
    Mirzoyan, R
    Pimpl, W
    Schwaiger, M
    Ziegler, SI
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1298 - 1302
  • [4] Continuous bed motion on clinical scanner: design, data correction, and reconstruction
    Panin, V. Y.
    Smith, A. M.
    Hu, J.
    Kehren, F.
    Casey, M. E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (20): : 6153 - 6174
  • [5] Evaluation of a novel Data Driven Gating technique for PET/CT imaging with continuous bed motion
    Meier, Joseph
    Schleyer, Paul
    Jones, Judson
    Hamill, James
    Mawlawi, Osama
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [6] Characteristics of a single LSO crystal layer high resolution research tomograph (HRRT) PET scanner.
    Boellaard, R
    Buijs, F
    Lenox, N
    Casey, ME
    Gremillion, T
    Jagt, P
    Lammertsma, AA
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 226P - 227P
  • [7] Elastic Motion Correction For Continuous Bed Motion Whole-body PET/CT
    Hong, Inki
    Jones, Judson
    Hamill, James
    Michel, Christian
    Casey, Michael
    [J]. 2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [8] Performance of a high sensitivity PET scanner based on LSO panel detectors
    Conti, M.
    Bendriem, B.
    Casey, M.
    Eriksson, L.
    Jakoby, B.
    Jones, W. F.
    Jones, J.
    Michel, C.
    Nahmias, C.
    Panin, V.
    Rappoport, V.
    Sibomana, M.
    Townsend, D. W.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1136 - 1142
  • [9] Performance of a high sensitivity PET scanner based on LSO panel detectors
    Conti, M.
    Bendriem, B.
    Casey, M.
    Eriksson, L.
    Jakoby, B.
    Jones, W. F.
    Jones, J.
    Michel, C.
    Nahmias, C.
    Panin, V.
    Rappoport, V.
    Sibomana, M.
    Townsend, D. W.
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2501 - 2505
  • [10] Comparison of a commercial PET-CT scanner with a dedicated high resolution scanner for brain imaging
    Anton-Rodriguez, J.
    Matthews, J.
    Julyan, Peter
    Djoukhadar, Ibrahim
    Russell, David
    Evans, G.
    Jackson, A.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)