Development and validation of a dynamic flowsheet model for a 350 MWe supercritical circulating fluidized bed boiler

被引:2
|
作者
Zhu, Shahong [1 ]
Zhang, Man [1 ]
Deng, Boyu [1 ]
Huang, Zhong [1 ]
Ding, Yi [2 ]
Wang, Gang [3 ]
Yang, Hairui [1 ]
Yue, Guangxi [1 ]
机构
[1] Tsinghua Univ, Dept Energy & Power Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
[2] SDIC Power Holding Co Ltd, Beijing 100034, Peoples R China
[3] Harbin Boiler Co Ltd, State Key Lab Efficient & Clean Coal Fired Util B, Harbin 150046, Peoples R China
关键词
Aspen Dynamics; Dynamic response characteristics; Heat transfer coefficient; Reaction kinetics; Step signal disturbance; Supercritical CFB boiler; OXY-FUEL COMBUSTION; SIMULATION; OPERATION;
D O I
10.1016/j.applthermaleng.2022.118265
中图分类号
O414.1 [热力学];
学科分类号
摘要
The circulating fluidized bed (CFB) boiler is highly recommended in peak shaving for its wide load regulating range compared with the pulverized coal (PC) boiler. However, the research on dynamic flowsheet model of the CFB boiler is quite limited due to its complex flow regime. In this paper, both steady state and dynamic flowsheet model of a supercritical 350 MWe CFB boiler was developed based on Aspen Plus and Aspen Dynamics software coupled with comprehensively user defined combustion kinetics and heat transfer coefficient with FORTRAN subroutines. This model was then validated by the operating data of the 350 MWe supercritical CFB boiler. Based on this model, the dynamic characteristics of three typical step signal disturbances, coal flow rate, primary flow rate and secondary air flow rate, were further analyzed to provide theoretical references to dynamic operation. Also, the quantitative relation between the stabilization time and step signal amplitude was calculated. The calculated dynamic characteristics demonstrates that the heat distribution does not vary much after adding step signal disturbances of coal flow rate, primary air flow rate and secondary air flow rate. The step signal disturbance of secondary air flow rate has less influence to the CFB boiler system compared with that of primary air flow rate. The superheated steam temperature is more sensitive to step signal disturbances compared with reheated steam temperature. The higher step signal amplitude results in longer stabilization time. Above all, this dynamic flowsheet model can not only be used to conduct dynamic behavior prediction and analysis but also provide transfer functions to the further development of CFB automatic control system.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Development of a supercritical and an ultra-supercritical circulating fluidized bed boiler
    Lyu, Junfu
    Yang, Hairui
    Ling, Wen
    Nie, Li
    Yue, Guangxi
    Li, Ruixin
    Chen, Ying
    Wang, Shilong
    [J]. FRONTIERS IN ENERGY, 2019, 13 (01) : 114 - 119
  • [2] Development of a supercritical and an ultra-supercritical circulating fluidized bed boiler
    Junfu Lyu
    Hairui Yang
    Wen Ling
    Li Nie
    Guangxi Yue
    Ruixin Li
    Ying Chen
    Shilong Wang
    [J]. Frontiers in Energy, 2019, 13 : 114 - 119
  • [3] Failure analysis of reheater tubes in a 350 MW supercritical circulating fluidized bed boiler
    Li, Jian
    Cao, Tieshan
    Zhang, Conghui
    Cheng, Congqian
    Zhao, Jie
    [J]. ENGINEERING FAILURE ANALYSIS, 2022, 137
  • [4] Conceptual design of an 800MWe supercritical pressure circulating fluidized bed boiler and its performance prediction
    Wu, YX
    Lu, JF
    Zhang, JS
    Yue, GX
    Yu, L
    [J]. Circulating Fluidized Bed Technology VIII, 2005, : 529 - 536
  • [5] A dynamic model for supercritical once-through circulating fluidized bed boiler-turbine units
    Zhang, Hongfu
    Gao, Mingming
    Fan, Haohao
    Zhang, Kaiping
    Zhang, Jiahui
    [J]. ENERGY, 2022, 241
  • [6] Development and Validation of a Dynamic Response Model for a Cold Flow Circulating Fluidized Bed
    Monazam, Esmail R.
    Breault, Ronald W.
    Freed, Adam D.
    Shadle, Lawrence
    Lawson, Larry
    Rowan, Steven L.
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2017, 56 (01) : 288 - 300
  • [7] Supercritical circulating fluidized bed technology for Lagisza 460 MWe power plant
    Venäläinen, L
    [J]. BALTICA VI: LIFE MANAGEMENT AND MAINTENANCE FOR POWER PLANTS, VOL 1 AND 2, 2004, 233-234 : 115 - 129
  • [8] Dynamic Characteristics Analysis of a 660 MW Ultra-Supercritical Circulating Fluidized Bed Boiler
    Yang, Chen
    Zhang, Zonglong
    Wu, Haochuang
    Deng, Kangjie
    [J]. ENERGIES, 2022, 15 (11)
  • [9] Research on energy distribution characteristics of supercritical circulating fluidized bed boiler
    Xie, Guowei
    Hu, Changhua
    Zhang, Peng
    Gu, Congyang
    Xin, Shengwei
    Wang, Hu
    Wu, Wanzhu
    Du, Jiajun
    [J]. THIRD INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2019, 227
  • [10] A mathematical model for a circulating fluidized bed (CFB) boiler
    Wang, QH
    Luo, ZY
    Li, XT
    Fang, MX
    Ni, MJ
    Cen, KF
    [J]. ENERGY, 1999, 24 (07) : 633 - 653