Patient-Specific Biomechanical Modeling of Bone Strength Using Statistically-Derived Fabric Tensors

被引:14
|
作者
Lekadir, Karim [1 ,2 ]
Noble, Christopher [1 ,3 ]
Hazrati-Marangalou, Javad [5 ]
Hoogendoorn, Corn [1 ,2 ]
van Rietbergen, Bert [5 ]
Taylor, Zeike A. [1 ,3 ]
Frangi, Alejandro F. [1 ,4 ]
机构
[1] Univ Sheffield, Ctr Computat Imaging & Simulat Technol Biomed, Sheffield, S Yorkshire, England
[2] Univ Pompeu Fabra, Dept Informat & Commun Technol, Barcelona, Spain
[3] Univ Sheffield, Dept Mech Engn, Sheffield, S Yorkshire, England
[4] Univ Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, England
[5] Eindhoven Univ, Dept Biomed Engn, Orthopaed Biomech, Eindhoven, Netherlands
关键词
Bone fracture; Finite element methods; Bone microarchitecture; Statistical predictive models; Fracture load estimation; FINITE-ELEMENT-ANALYSIS; QUANTITATIVE COMPUTED-TOMOGRAPHY; STRUCTURAL ANISOTROPY; SIDEWAYS FALL; LOAD-TRANSFER; MICRO-CT; FRACTURE; MICROARCHITECTURE; FAILURE; ARCHITECTURE;
D O I
10.1007/s10439-015-1432-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Low trauma fractures are amongst the most frequently encountered problems in the clinical assessment and treatment of bones, with dramatic health consequences for individuals and high financial costs for health systems. Consequently, significant research efforts have been dedicated to the development of accurate computational models of bone biomechanics and strength. However, the estimation of the fabric tensors, which describe the microarchitecture of the bone, has proven to be challenging using in vivo imaging. On the other hand, existing research has shown that isotropic models do not produce accurate predictions of stress states within the bone, as the material properties of the trabecular bone are anisotropic. In this paper, we present the first biomechanical study that uses statistically-derived fabric tensors for the estimation of bone strength in order to obtain patient-specific results. We integrate a statistical predictive model of trabecular bone microarchitecture previously constructed from a sample of ex vivo micro-CT datasets within a biomechanical simulation workflow. We assess the accuracy and flexibility of the statistical approach by estimating fracture load for two different databases and bone sites, i.e., for the femur and the T12 vertebra. The results obtained demonstrate good agreement between the statistically-driven and micro-CT-based estimates, with concordance coefficients of 98.6 and 95.5% for the femur and vertebra datasets, respectively.
引用
收藏
页码:234 / 246
页数:13
相关论文
共 50 条
  • [1] Patient-Specific Biomechanical Modeling of Bone Strength Using Statistically-Derived Fabric Tensors
    Karim Lekadir
    Christopher Noble
    Javad Hazrati-Marangalou
    Corné Hoogendoorn
    Bert van Rietbergen
    Zeike A. Taylor
    Alejandro F. Frangi
    Annals of Biomedical Engineering, 2016, 44 : 234 - 246
  • [2] Patient-Specific Biomechanical Modeling of Cardiac Amyloidosis - A Case Study
    Chapelle, D.
    Felder, A.
    Chabiniok, R.
    Guellich, A.
    Deux, J. -F.
    Damy, T.
    FUNCTIONAL IMAGING AND MODELING OF THE HEART (FIMH 2015), 2015, 9126 : 295 - 303
  • [3] Patient-Specific Biomechanical Modeling of the Lung Tumor for Radiation Therapy
    Giroux, M.
    Ladjal, H.
    Beuve, M.
    Giraud, P.
    Shariat, B.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 : 95 - 96
  • [4] Credibility assessment of patient-specific computational modeling using patient-specific cardiac modeling as an exemplar
    Galappaththige, Suran
    Gray, Richard A.
    Costa, Caroline Mendonca
    Niederer, Steven
    Pathmanathan, Pras
    PLOS COMPUTATIONAL BIOLOGY, 2022, 18 (10)
  • [5] Development of a patient-specific bone analog for the biomechanical evaluation of custom implants
    Horn, Timothy J.
    Harrysson, Ola L. A.
    West, Harvey A., II
    Little, Jeffrey P.
    Marcellin-Little, Denis J.
    RAPID PROTOTYPING JOURNAL, 2014, 20 (01) : 41 - 49
  • [6] Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment
    Wang, Qian
    Sirois, Eric
    Sun, Wei
    JOURNAL OF BIOMECHANICS, 2012, 45 (11) : 1965 - 1971
  • [7] Patient-specific finite element modeling for femoral bone augmentation
    Basafa, Ehsan
    Armiger, Robert S.
    Kutzer, Michael D.
    Belkoff, Stephen M.
    Mears, Simon C.
    Armand, Mehran
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (06) : 860 - 865
  • [8] Modeling mucopolysaccharidosis type VII using patient-specific iPSC-derived neurons
    Bayo-Puxan, N.
    Creyssels, S.
    Saliinas, S.
    Pescia, C.
    Bosch, A.
    Vellard, M.
    Consiglio, A.
    Kremer, E. J.
    HUMAN GENE THERAPY, 2016, 27 (11) : A78 - A78
  • [9] Biomechanical analysis of patient-specific femur model of osteogenesis imperfecta with cortical and cancellous bone
    Tan, L. C.
    Som, M. H. Mat
    Basaruddin, K. S.
    Yazid, H.
    Daud, R.
    Awang, M. S.
    6TH INTERNATIONAL CONFERENCE ON APPLICATIONS AND DESIGN IN MECHANICAL ENGINEERING, 2019, 670
  • [10] Patient-Specific iPSC-Derived RPE for Modeling of Retinal Diseases
    Nguyen, Huy V.
    Li, Yao
    Tsang, Stephen H.
    JOURNAL OF CLINICAL MEDICINE, 2015, 4 (04): : 567 - 578