Practical implications of motion correction with motion insensitive radial k-space acquisitions in MRI

被引:2
|
作者
Almuqbel, Mustafa M. [1 ,2 ,3 ]
Leeper, Gareth [3 ]
Palmer, David N. [4 ,5 ]
Mitchell, Nadia L. [5 ,6 ]
Russell, Katharina N. [5 ,7 ]
Keenan, Ross J. [1 ,2 ,3 ]
Melzer, Tracy R. [1 ,2 ,8 ]
机构
[1] Nev Zealand Brain Res Inst, Christchurch, New Zealand
[2] Univ Otago, Dept Med, Christchurch, New Zealand
[3] Pacific Radiol Grp, Christchurch, New Zealand
[4] Lincoln Univ, Fac Agr & Life Sci, Lincoln, New Zealand
[5] BARN, Lincoln, New Zealand
[6] Univ Otago, Dept Radiol, Christchurch, New Zealand
[7] Lincoln Univ, Dept Wine Food & Mol Biosci, Lincoln, New Zealand
[8] Ctr Res Excellence, Brain Res New Zealand Rangahau Roro Aotearoa, Christchurch, New Zealand
来源
BRITISH JOURNAL OF RADIOLOGY | 2018年 / 91卷 / 1087期
关键词
IMAGE QUALITY; PROPELLER; IMPROVEMENT;
D O I
10.1259/bjr.20170593
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To highlight specific instances when radial k-space acquisitions in MRI result in image artifacts and how to ameliorate such artifacts. Methods: We acquired axial T-2 weighted MR images on (1) the American College of Radiology (ACR) phantom and (2) a sedated sheep with rectilinear and multiblade radial k-space filling acquisitions. Images were acquired on four (2 x 1.5T and 2 x 3T) different MRI scanners. For the radial k-space acquisitions, we acquired images with and without motion correction. All images were visually inspected for the presence of artifact. Results: Images collected via the conventional rectilinear method were of diagnostic quality and free of artifact. Both ACR and sheep images acquired with radial k-space acquisitions and motion correction suffered significant artifact at different slice locations, scan sessions and across all the four scanners. Severity of the artifact was associated with echo train length. However, the artifact was eliminated when motion correction was not employed. Conclusion: When little to no motion is present, the use of motion correction with radial k-space acquisitions can compromise image quality. However, image quality is quickly improved, and the artifact eliminated, by repeating the scan without motion correction or by using a conventional rectilinear alternative. Advances in Knowledge: By improving awareness and understanding of this artifact, MRI users will be able to adjust MRI protocols, resulting in more successful scanning sessions, better image quality, fewer call backs and increased diagnostic confidence.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Retrospective Rigid Motion Correction in k-Space for Segmented Radial MRI
    Vaillant, Ghislain
    Prieto, Claudia
    Kolbitsch, Christoph
    Penney, Graeme
    Schaeffter, Tobias
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (01) : 1 - 10
  • [2] Motion correction using the k-space phase difference of orthogonal acquisitions
    Welch, EB
    Felmlee, JP
    Ehman, RL
    Manduca, A
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) : 147 - 156
  • [3] Two-step navigatorless correction algorithm for radial k-space MRI acquisitions
    Shankaranarayanan, A
    Wendt, M
    Lewin, JS
    Duerk, JL
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (02) : 277 - 288
  • [4] Motion correction properties of the shells k-space trajectory
    Shu, Yunhong
    Elliott, Andrew M.
    Riederer, Stephen J.
    Bernstein, Matt A.
    MAGNETIC RESONANCE IMAGING, 2006, 24 (06) : 739 - 749
  • [5] Detection and Correction of Cardiac MRI Motion Artefacts During Reconstruction from k-space
    Oksuz, Ilkay
    Clough, James
    Ruijsink, Bram
    Puyol-Anton, Esther
    Bustin, Aurelien
    Cruz, Gastao
    Prieto, Claudia
    Rueckert, Daniel
    King, Andrew P.
    Schnabel, Julia A.
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2019, PT IV, 2019, 11767 : 695 - 703
  • [6] Motion correction of MRI joint images using orthogonal k-space phase difference
    Welch, EB
    Manduca, A
    RADIOLOGY, 2001, 221 : 221 - 221
  • [7] SISMIK for Brain MRI: Deep-Learning-Based Motion Estimation and Model-Based Motion Correction in k-Space
    Dabrowski, Oscar
    Falcone, Jean-Luc
    Klauser, Antoine
    Songeon, Julien
    Kocher, Michel
    Chopard, Bastien
    Lazeyras, Francois
    Courvoisier, Sebastien
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2025, 44 (01) : 396 - 408
  • [8] Motion artifact suppression in MRI using k-space overlap processing
    Kadah, Yasser M.
    PROCEEDINGS OF THE 25TH NATIONAL RADIO SCIENCE CONFERENCE: NRSC 2008, 2008, : U221 - U229
  • [9] GENERALIZED K-SPACE ANALYSIS AND CORRECTION OF MOTION EFFECTS IN MR-IMAGING
    LAUZON, ML
    RUTT, BK
    MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (04) : 438 - 446
  • [10] Self-supervised k-Space Regularization for Motion-Resolved Abdominal MRI Using Neural Implicit k-Space Representations
    Spieker, Veronika
    Eichhorn, Hannah
    Stelter, Jonathan K.
    Huang, Wenqi
    Braren, Rickmer F.
    Rueckert, Daniel
    Costabal, Francisco Sahli
    Hammernik, Kerstin
    Prieto, Claudia
    Karampinos, Dimitrios C.
    Schnabel, Julia A.
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2024, PT VII, 2024, 15007 : 614 - 624