SKIN DOSE IMPACT FROM VACUUM IMMOBILIZATION DEVICE AND CARBON FIBER COUCH IN INTENSITY MODULATED RADIATION THERAPY FOR PROSTATE CANCER

被引:18
|
作者
Lee, Kuo-Wei
Wu, Jian-Kuen
Jeng, Shiu-Chen
Liu, Yen-Wan Hsueh
Cheng, Jason Chia-Hsien [1 ]
机构
[1] Natl Taiwan Univ Hosp, Dept Oncol, Taipei 100, Taiwan
关键词
Intensity-modulated radiation therapy; Prostate cancer; Skin; Vacuum immobilization device; Couch; PHOTON-BEAM ATTENUATION; RADIOTHERAPY; ENERGY;
D O I
10.1016/j.meddos.2008.10.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To investigate the unexpected skin dose increase from intensity-modulated radiation therapy (IMRT) on vacuum cushions and carbon-fiber couches and then to modify the dosimetric plan accordingly. Eleven prostate cancer patients undergoing IMRT were treated in prone position with a vacuum cushion. Two under-couch beams scattered the radiation from the vacuum cushion and carbon-fiber couch. The IMRT plans with both devices contoured were compared with the plans not contouring them. The skin doses were measured using thermoluminescent dosimeters (TLDs) placed on the inguinal regions in a single IMRT fraction. Tissue equivalent thickness was transformed for both devices with the relative densities. The TLD-measured skin doses (59.5 +/- 9.5 cGy and 55.6 +/- 5.9 cGy at left and right inguinal regions, respectively) were significantly higher than the calculated doses (28.7 +/- 4.7 cGy; p = 2.2 x 10(-5) and 26.2 +/- 4.3 cGy; p = 1.5 x 10-5) not contouring the vacuum cushion and carbon-fiber couch. The calculated skin doses with both devices contoured (59.1 +/- 8.8 cGy and 55.5 +/- 5.7 cGy) were similar to the TLD-measured doses. In addition, the calculated skin doses using the vacuum cushion and a converted thickness of the simulator couch were no different from the TLD-measured doses. The recalculated doses of rectum and bladder did not change significantly. The dose that covered 95% of target volume was less than the prescribed dose in 4 of 11 patients, and this problem was solved after re-optimization applying the corrected contours. The vacuum cushion and carbon-fiber couch contributed to increased skin doses. The tissue-equivalent-thickness method served as an effective way to correct the dose variations. (C) 2009 American Association of Medical Dosimetrists.
引用
收藏
页码:228 / 232
页数:5
相关论文
共 50 条
  • [1] Increased Skin Dose in Supine Craniospinal Irradiation Due to Carbon Fiber Couch and Vacuum Bag Immobilization Device
    Robertson, D.
    Zhao, Z.
    Wang, X.
    Yang, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3581 - 3582
  • [2] Carbon fiber couch effects on skin dose for volumetric modulated arcs
    Mihaylov, Ivaylo B.
    Bzdusek, Karl
    Kaus, Michael
    MEDICAL PHYSICS, 2011, 38 (05) : 2419 - 2423
  • [3] High-dose intensity modulated radiation therapy for prostate cancer
    Kuban D.A.
    Dong L.
    Current Urology Reports, 2004, 5 (3) : 197 - 202
  • [4] Verification of the dose attenuation of a newly developed vacuum cushion for intensity-modulated radiation therapy of prostate cancer
    Takakura T.
    Ito Y.
    Higashikawa A.
    Nishiyama T.
    Sakamoto T.
    Radiological Physics and Technology, 2016, 9 (2) : 270 - 276
  • [5] INTENSITY MODULATED RADIATION THERAPY FOR PROSTATE CANCER
    Obata, S.
    Takatsuki, H.
    Ohta, Y.
    Kan, T.
    Kanegae, S.
    Inoue, Y.
    Matsuo, M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S383 - S384
  • [6] Impact of Intensity Modulated Radiation Therapy and Hypofractionated Radiation Therapy on Overall Survival in Prostate Cancer
    Chalubinska-Fendler, J. P.
    Wojciech, F.
    Michal, S.
    Bartlomiej, T.
    Jolanta, L.
    Jacek, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S440 - S441
  • [7] Rectal Dose Constraints for Intensity Modulated Radiation Therapy of the Prostate
    Swanson, Gregory P.
    Stathakis, Sotirios
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2011, 34 (02): : 188 - 195
  • [8] Impact of radiation attenuation by a carbon fiber couch on patient dose verification
    Yu, Chun-Yen
    Chou, Wen-Tsae
    Liao, Yi-Jen
    Lee, Jeng-Hung
    Liang, Ji-An
    Hsu, Shih-Ming
    SCIENTIFIC REPORTS, 2017, 7
  • [9] Impact of radiation attenuation by a carbon fiber couch on patient dose verification
    Chun-Yen Yu
    Wen-Tsae Chou
    Yi-Jen Liao
    Jeng-Hung Lee
    Ji-An Liang
    Shih-Ming Hsu
    Scientific Reports, 7
  • [10] Impact of obesity on outcomes after definitive dose escalated intensity modulated radiation therapy for localized prostate cancer
    Wang, Lora S.
    Ruth, Karen J.
    Smaldone, Marc C.
    Kutikov, Alexander
    Sobczak, Mark L.
    Viterbo, Rosalia
    Horwitz, Eric M.
    JOURNAL OF CLINICAL ONCOLOGY, 2014, 32 (04)