A preliminary study determining the feasibility of electromagnetic tracking for kinematics at the ankle joint complex

被引:30
|
作者
Woodburn, J
Turner, DE
Helliwell, PS
Barker, S
机构
[1] Univ Leeds, Sch Med, Rheumatol & Rehabil Res Unit, Leeds LS2 9NZ, W Yorkshire, England
[2] Univ Huddersfield, Dept Podiatry, Huddersfield HD1 3DH, W Yorkshire, England
[3] St Lukes Hosp, Bradford BD5 0NA, W Yorkshire, England
关键词
electromagnetic tracking; ankle joint complex; three-dimensional kinematics; rheumatoid arthritis;
D O I
10.1093/rheumatology/38.12.1260
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. To determine the feasibility of using electromagnetic tracking (EMT) for quantifying three-dimensional kinematics at the ankle; joint complex (AJC). Methods. AJC kinematics were recorded in 10 normal healthy adults, and 10 rheumatoid arthritis patients presenting with AJC instability and deformity who were undergoing footwear and orthotic intervention. Results. Kinematics in normal subjects had strong face validity, curve shape showing moderate (n = 9), good (n = 8) or excellent (n = 4) agreement with data from seven published studies. The range of motion about the x-axis (15.2 degrees) was similar to reference values (17.0 degrees), but our technique underestimated rotations about the y- (8.1 degrees vs 14.0 degrees) and z-axes (7.7 degrees vs 12.2 degrees). In the rheumatoid arthritis pronated foot group, eversion and internal rotation during the stance phase of gait were between 2 and 5 times greater than for normal subjects. The use of a corrective fool orthosis in this group restored normal kinematics, reducing maximum eversion and internal rotation by 57 and 68%, respectively. Conclusion. A new technique for measuring kinematics at the AJC is described. Based upon the findings of this pilot study, EMT may be useful for diagnosing AJC dysfunction and quantifying the mechanical efficacy of footwear and, orthosis interventions.
引用
收藏
页码:1260 / 1268
页数:9
相关论文
共 50 条
  • [1] The relationship between hallux dorsiflexion and ankle joint complex frontal plane kinematics: A preliminary study
    Halstead, J
    Turner, DE
    Redmond, AC
    CLINICAL BIOMECHANICS, 2005, 20 (05) : 526 - 531
  • [2] Kinematics of the ankle joint complex in snowboarding
    Delorme, Sébastien
    Tavoularis, Stavros
    Lamontagne, Mario
    Journal of Applied Biomechanics, 2005, 21 (04): : 394 - 403
  • [3] Kinematics of the ankle joint complex in snowboarding
    Delorme, S
    Tavoularis, S
    Lamontagne, M
    JOURNAL OF APPLIED BIOMECHANICS, 2005, 21 (04) : 394 - 403
  • [4] Three-Dimensional Kinematics of an Unconstrained Ankle Arthroplasty: A Preliminary In Vivo Videofluoroscopic Feasibility Study
    List, Renate
    Foresti, Mauro
    Gerber, Hans
    Goldhahn, Joerg
    Rippstein, Pascal
    Stuessi, Edgar
    FOOT & ANKLE INTERNATIONAL, 2012, 33 (10) : 883 - 892
  • [5] Determining dual Euler angles of the ankle complex in vivo using "Flock of birds" electromagnetic tracking device
    Ying, N
    Kim, W
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (01): : 98 - 107
  • [6] Assessment of elbow joint kinematics in passive motion by electromagnetic motion tracking
    Bottlang, M
    Madey, SM
    Steyers, CM
    Marsh, JL
    Brown, TD
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2000, 18 (02) : 195 - 202
  • [7] Three-dimensional kinematics at the ankle joint complex in rheumatoid arthritis.
    Woodburn, J
    Helliwell, PS
    ARTHRITIS AND RHEUMATISM, 2001, 44 (09): : S366 - S366
  • [8] Effect of Post-traumatic Tibiotalar Osteoarthritis on Kinematics of the Ankle Joint Complex
    Kozanek, Michal
    Rubash, Harry E.
    Li, Guoan
    de Asla, Richard J.
    FOOT & ANKLE INTERNATIONAL, 2009, 30 (08) : 734 - 740
  • [9] Evaluation of an electromagnetic position tracking device for measuring in vivo, dynamic joint kinematics
    Schuler, NB
    Bey, MJ
    Shearn, JT
    Butler, DL
    JOURNAL OF BIOMECHANICS, 2005, 38 (10) : 2113 - 2117
  • [10] Electromagnetic marker tracking in the CyberKnife suite: A feasibility study
    Mihaescu, C
    Dieterich, S
    Testa, C
    Mocanu, M
    Cleary, K
    MEDICAL PHYSICS, 2004, 31 (06) : 1830 - 1830