PNA biosensor based on reduced graphene oxide/water soluble quantum dots for the detection of Mycobacterium tuberculosis

被引:71
|
作者
Zaid, Mohd Hazani Mat [1 ]
Abdullah, Jaafar [1 ,2 ]
Yusof, Nor Azah [1 ,2 ]
Sulaiman, Yusran [1 ,2 ]
Wasoh, Helmi [3 ]
Noh, Mohd Fairulnizal Md [4 ]
Issa, Rahizan [5 ]
机构
[1] Univ Putra Malaysia, Inst Adv Technol, Upm Serdang 43400, Selangor Darul, Malaysia
[2] Univ Putra Malaysia, Fac Sci, Dept Chem, Upm Serdang 43400, Selangor Darul, Malaysia
[3] Univ Putra Malaysia, Fac Biotechnol & Biomol Sci, Dept Bioproc Technol, Upm Serdang 43400, Selangor Darul, Malaysia
[4] Inst Med Res, Cardiovasc Diabet & Nutr Res Ctr, Jalan Pahang, Kuala Lumpur 50588, Malaysia
[5] Inst Med Res, Bacteriol Unit, Infect Dis Res Ctr, Jalan Pahang, Kuala Lumpur 50588, Malaysia
来源
关键词
Mycobacterium tuberculosis; Graphene oxide; Quantum dots; Biosensor; METHYLENE-BLUE; OXIDE; REDUCTION; ELECTRODE; DNA; ETHYLENEDIAMINE; FERRICYANIDE; SENSOR;
D O I
10.1016/j.snb.2016.10.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical biosensor holds great interest in establishing robust analytical method for Mycobacterium tuberculosis (M. Tuberculosis). Herein, fabrication of a highly sensitive electrochemical PNA biosensor based on functionalized, graphene oxide (NH2-GO) composited with CdS quantum dots (QDs) for the detection of M. Tuberculosis has been described. Firstly, NElz-GO/QAs was applied onto screen-printed carbon electrode (SPCE) surface by electro-deposition method, then the PNA probe was immobilized onto the surface of NH2-GO/QDs modified SPCE via EDC/NHS coupling technique. Subsequently, the developed PNA biosensor was used to hybridize with target DNA. Differential pulse voltammetry (DPV) was employed to monitor the hybridization event by using methylene blue (MB) as the electrochemical indicator. Under the optimal conditions, a linear detection range of the PNA biosensor was obtained from 1 x 10(-11) to 1 x 10(-7) M with the detection limit of 8.948 x 10(-13) M. The biosensor has successfully discriminated between negative and positive sample of M. Tuberculosis DNA sequences from real sample analysis. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1024 / 1034
页数:11
相关论文
共 50 条
  • [1] Reduced graphene oxide nanoribbon immobilized gold nanoparticle based electrochemical DNA biosensor for the detection of Mycobacterium tuberculosis
    Mogha, Navin Kumar
    Sahu, Vikrant
    Sharma, Raj Kishore
    Masram, Dhanraj T.
    [J]. JOURNAL OF MATERIALS CHEMISTRY B, 2018, 6 (31) : 5181 - 5187
  • [2] Water soluble reduced graphene oxide as an efficient photoluminescence quencher for semiconductor quantum dots
    Tang, Haiping
    Sun, Luwei
    He, Haiping
    [J]. OPTICAL MATERIALS, 2017, 64 : 9 - 12
  • [3] Reduced Graphene Oxide/TEMPO-Nanocellulose Nanohybrid-Based Electrochemical Biosensor for the Determination of Mycobacterium tuberculosis
    Zaid, Mohd Hazani Mat
    Abdullah, Jaafar
    Yusof, Nor Azah
    Wasoh, Helmi
    Sulaiman, Yusran
    Noh, Mohd Fairulnizal Md
    Issa, Rahizan
    [J]. JOURNAL OF SENSORS, 2020, 2020
  • [4] Green synthesis of reduced-graphene oxide quantum dots and application for colorimetric biosensor
    Hwang, Juil
    Anh Duy Duong Le
    Cong Tai Trinh
    Quynh Thuy Le
    Lee, Kwang-Geol
    Kim, Jaeyong
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2021, 318
  • [5] A reduced graphene oxide based electrochemical biosensor for tyrosine detection
    Wei, Junhua
    Qiu, Jingjing
    Li, Li
    Ren, Liqiang
    Zhang, Xianwen
    Chaudhuri, Jharna
    Wang, Shiren
    [J]. NANOTECHNOLOGY, 2012, 23 (33)
  • [6] A reduced graphene oxide based biosensor for high-sensitive detection of phenols in water samples
    Zhou, Xiao-Hong
    Liu, Lan-Hua
    Bai, Xue
    Shi, Han-Chang
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 181 : 661 - 667
  • [7] Nanostructured Hybrid Materials Based on Semiconductor Quantum Dots and Graphene, Graphene Oxide, or Reduced Graphene Oxide
    Garcia-Gutierrez, Domingo, I
    [J]. CURRENT NANOSCIENCE, 2022, 18 (06) : 655 - 658
  • [8] A polyaniline-reduced graphene oxide nanocomposite as a redox nanoprobe in a voltammetric DNA biosensor for Mycobacterium tuberculosis
    Yuhan Chen
    Youlun Li
    Yang Yang
    Fangni Wu
    Jun Cao
    Lijuan Bai
    [J]. Microchimica Acta, 2017, 184 : 1801 - 1808
  • [9] A polyaniline-reduced graphene oxide nanocomposite as a redox nanoprobe in a voltammetric DNA biosensor for Mycobacterium tuberculosis
    Chen, Yuhan
    Li, Youlun
    Yang, Yang
    Wu, Fangni
    Cao, Jun
    Bai, Lijuan
    [J]. MICROCHIMICA ACTA, 2017, 184 (06) : 1801 - 1808
  • [10] Graphene Quantum Dots-based Electrochemical Biosensor for Catecholamine Neurotransmitters Detection
    Baluta, Sylwia
    Lesiak, Anna
    Cabaj, Joanna
    [J]. ELECTROANALYSIS, 2018, 30 (08) : 1773 - 1782