Evaluation of Advia Centaur® automated chemiluminescence immunoassay for determining total homocysteine in plasma

被引:28
|
作者
Demuth, K
Ducros, W
Michelsohn, S
Paul, JL
机构
[1] Hop Europeen Georges Pompidou, Lab Biochim Cardiovasc, F-75015 Paris, France
[2] Univ Paris 11, Fac Pharm, Lab Biochim Appl, Chatenay Malabry, France
[3] Univ Paris 11, Fac Pharm, IFR ISIT, Chatenay Malabry, France
[4] CHU Grenoble, Dept Biol Integree, Grenoble, France
关键词
method comparison; homocysteine; chemiluminescence; immunoassay; cardiovascular disease;
D O I
10.1016/j.cccn.2004.06.012
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background. A lot of methods are now available for total plasma homocysteine (tHcy) determination. HPLC with fluorescence detection were the most widely used methods until recently but immunoassays, easier to use, currently supplant in-house laboratory methods. Methods. The latest commercial automated chemiluminescence immunoassay (ICL) for tHcy, developed on the ADVIA Centaur(R) analyzer (Bayer Diagnostics), was fully evaluated and compared with a current HPLC method. Results. The ICL-ADVIA Centaur(R) method had a detection limit <0.9 mumol/l and was linear for tHcy between 2.4 and 58.8 mumol/l. The within- and between assay imprecision was <6% and <7%, respectively. The analytical recovery ranged from 93.5% to 109.7%. The comparison of 168 clinical plasma specimens indicated a good correlation between the two methods (r=0.96, p<0.0001) but a systematic positive bias for ICL-ADVIA Centaur(R) method (mean difference=3.0 mumol/l). Conclusions. The ADVIA Centaur(R) method is a useful and practicable alternative to HPLC methods for tHcy determination. The ICL method is even more convenient than chromatographic methods for routine use because of its significantly higher throughput (200 samples/h vs. 40 per 24 h). However, the agreement among methods is insufficient to allow them to be used interchangeably. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 120
页数:8
相关论文
共 50 条
  • [1] An automated immunoassay for plasma Homocysteine on the Bayer ADVIA® Centaur™.
    Mindicino, H
    Luddy, MA
    Ogbonna, G
    Belenky, A
    Vajdi, M
    Armstrong, G
    [J]. CLINICAL CHEMISTRY, 2000, 46 (06) : A78 - A79
  • [2] ADVIA Centaur™ Automated Immunoassay
    Lee, Jung-Sun
    Min, Won Ki
    Park, Eun Hwa
    Lim, Woo-Sung
    Choi, Sung-Lim
    Son, Byung-Ho
    Kim, Sung-Bae
    Ahn, Jin-Hee
    Ahn, Sei-Hyun
    [J]. JOURNAL OF BREAST CANCER, 2008, 11 (03) : 116 - 124
  • [3] Multicenter analytical evaluation of an automated immunoassay for total plasma homocysteine
    Wu, AHB
    Holtman, V
    Apple, FS
    Ricchiuti, V
    DiBello, PM
    Jacobsen, D
    [J]. ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2000, 30 (02): : 185 - 190
  • [4] The evaluation of an automated chemiluminescent immunoassay for complexed PSA on the Bayer ADVIA Centaur™ System.
    Datta, P
    Tasaico, K
    Wright, A
    Zhang, P
    [J]. CLINICAL CHEMISTRY, 2001, 47 (06) : A127 - A127
  • [5] Evaluation of new automated immunoassay for total homocysteine
    Needham, J
    Bowen, S
    Ramage, J
    Nokes, T
    [J]. THROMBOSIS AND HAEMOSTASIS, 1999, : 313 - 313
  • [6] Analytical and clinical evaluation of the Bayer ADVIA Centaur homocysteine assay
    Tewari, PC
    Zhang, B
    Conarpe, C
    Bluestein, BI
    [J]. CLINICAL CHEMISTRY, 2004, 50 (06) : A6 - A6
  • [7] Analytical and clinical evaluation of the Bayer ADVIA Centaur® homocysteine assay
    Tewari, PC
    Zhang, B
    Bluestein, BI
    [J]. CLINICA CHIMICA ACTA, 2004, 342 (1-2) : 171 - 178
  • [8] Multisite evaluation of the Bayer ADVIA Centaur® CP Immunoassay System
    Dillon, P. W.
    Fink, D. J.
    Liu, K. M.
    Wang, H.
    Simmons, T.
    Sharma, S.
    Eisenzoph, R.
    Billoo, M.
    Tan, S.
    [J]. CLINICAL CHEMISTRY, 2006, 52 (06) : A193 - A193
  • [9] Performance evaluation of the free PSA immunoassay on the ADVIA Centaur® systems
    Mickelson, K. E.
    Lin, S.
    Thakur, K.
    White, T.
    Yepes, T.
    Morris, D. L.
    [J]. CLINICAL CHEMISTRY, 2008, 54 (06) : A132 - A132
  • [10] Evaluation of the Payer ADVIA Centaur PSA, a new automated chemiluminescent immunoassay for prostate specific antigen.
    Datta, P
    Tasaico, K
    Curley, J
    [J]. CLINICAL CHEMISTRY, 2000, 46 (06) : A163 - A163