Investigating the Ionization of Dissolved Organic Matter by Electrospray

被引:34
|
作者
Patriarca, Claudia [1 ]
Balderrama, Andrea [1 ,2 ]
Moze, Martina [1 ]
Sjoberg, Per J. R. [1 ]
Bergquist, Jonas [1 ]
Tranvik, Lars J. [2 ]
Hawkes, Jeffrey A. [1 ]
机构
[1] Uppsala Univ, Dept Chem BMC, Analyt Chem, S-75237 Uppsala, Sweden
[2] Uppsala Univ, Dept Ecol & Genet, Limnol, S-75237 Uppsala, Sweden
基金
瑞典研究理事会;
关键词
SIZE-EXCLUSION CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; MARINE; ONLINE; CARBON; ACIDS;
D O I
10.1021/acs.analchem.0c03438
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrospray ionization (ESI) operating in the negative mode coupled to high-resolution mass spectrometry is the most popular technique for the characterization of dissolved organic matter (DOM). The vast molecular heterogeneity and the functional group diversity of this complex mixture prevents the efficient ionization of the organic material by a single ionization source, so the presence of uncharacterized material is unavoidable. The extent of this poorly ionizable pool of carbon is unknown, is presumably variable between samples, and can only be assessed by the combination of analysis with a uniform detection method. Charged aerosol detection (CAD), whose response is proportional to the amount of nonvolatile material and is independent from the physicochemical properties of the analytes, is a suitable candidate. In this study, a fulvic acid mixture was fractionated and analyzed by high-pressure liquid chromatography-mass spectrometry in order to investigate the polarity and size distributions of highly and poorly ionizable material in the sample. Additionally, DOM samples of terrestrial and marine origins were analyzed to evaluate the variability of these pools across the land-sea aquatic continuum. The relative response factor values indicated that highly ionizable components of aquatic DOM mixtures are more hydrophilic and have lower molecular weight than poorly ionizable components. Additionally, a discrepancy between the samples of terrestrial and marine origins was found, indicating that marine samples are better represented by ESI than terrestrial samples, which have an abundant portion of hydrophobic poorly ionizable material.
引用
收藏
页码:14210 / 14218
页数:9
相关论文
共 50 条
  • [1] Molecular weight distributions of fractions of dissolved organic matter by electrospray ionization/mass spectrometry
    Rostad, CE
    Leenheer, JA
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : U514 - U515
  • [2] Natural dissolved organic matter affects electrospray ionization during analysis of emerging contaminants by mass spectrometry
    Wickramasekara, Samanthi
    Hernandez-Ruiz, Selene
    Abrell, Leif
    Arnold, Robert
    Chorover, Jon
    [J]. ANALYTICA CHIMICA ACTA, 2012, 717 : 77 - 84
  • [3] Insights on photochemical degradation of dissolved organic matter from electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    Gueguen, Celine
    Islam, Sohidul
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [4] Ionization selectivity of electrospray and atmospheric pressure photoionization FT-ICR MS for petroleum refinery wastewater dissolved organic matter
    He, Chen
    Fang, Zhi
    Li, Yongyong
    Jiang, Chunqing
    Zhao, Suoqi
    Xu, Chunming
    Zhang, Yahe
    Shi, Quan
    [J]. ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2021, 23 (10) : 1466 - 1475
  • [5] Investigating the Effects of Small Synthetic Organic Matters on Dissolved Organic Matter Adsorption
    Yan, Liang
    Jiang, Lan
    Tang, Yingdong
    Yu, Hao
    Sheng, Sheng
    Yu, Guanglu
    [J]. WATER AIR AND SOIL POLLUTION, 2015, 226 (11):
  • [6] Investigating the Effects of Small Synthetic Organic Matters on Dissolved Organic Matter Adsorption
    Liang Yan
    Lan Jiang
    Yingdong Tang
    Hao Yu
    Sheng Sheng
    Guanglu Yu
    [J]. Water, Air, & Soil Pollution, 2015, 226
  • [7] Molecular formulae of marine and terrigenous dissolved organic matter detected by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    Koch, BP
    Witt, MR
    Engbrodt, R
    Dittmar, T
    Kattner, G
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (13) : 3299 - 3308
  • [8] Molecular-level chemical characterization and bioavailability of dissolved organic matter in stream water using electrospray-ionization mass spectrometry
    Seitzinger, SP
    Hartnett, H
    Lauck, R
    Mazurek, M
    Minegishi, T
    Spyres, G
    Styles, R
    [J]. LIMNOLOGY AND OCEANOGRAPHY, 2005, 50 (01) : 1 - 12
  • [9] Use of electrospray ionization (ESI) mass spectrometry to investigate complex dissolved organic matter (DOM) and its potential applications in phytoplankton research
    Sipler, Rachel
    Seitzinger, Sybil
    [J]. HARMFUL ALGAE, 2008, 8 (01) : 182 - 187
  • [10] Investigation of dissolved organic carbon from water extracts of biochars by electrospray ionization/mass spectrometry
    Rostad, Colleen E.
    Rutherford, David W.
    Wershaw, Robert L.
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 242