Patlak Image Estimation From Dual Time-Point List-Mode PET Data

被引:52
|
作者
Zhu, Wentao [1 ]
Li, Quanzheng [2 ]
Bai, Bing [3 ]
Conti, Peter S. [3 ]
Leahy, Richard M. [1 ]
机构
[1] Univ So Calif, Inst Signal & Image Proc, Los Angeles, CA 90089 USA
[2] Massachusetts Gen Hosp, Boston, MA 02114 USA
[3] Univ So Calif, Dept Radiol, Los Angeles, CA 90089 USA
基金
美国国家卫生研究院;
关键词
Dual time-point; dynamic positron emission tomography (PET); lesion detection; Patlak; standardized uptake value (SUV); whole body; POSITRON-EMISSION-TOMOGRAPHY; F-18-FDG PET; FDG PET; RECONSTRUCTION ALGORITHM; PARAMETRIC IMAGES; KINETIC-MODEL; RESOLUTION; HUMANS; TUMOR;
D O I
10.1109/TMI.2014.2298868
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We investigate using dual time-point PET data to perform Patlak modeling. This approach can be used for whole body dynamic PET studies in which we compute voxel-wise estimates of Patlak parameters using two frames of data for each bed position. Our approach directly uses list-mode arrival times for each event to estimate the Patlak parametric image. We use a penalized likelihood method in which the penalty function uses spatially variant weighting to ensure a count independent local impulse response. We evaluate performance of the method in comparison to fractional changes in SUV values (%DSUV) between the two frames using Cramer Rao analysis and Monte Carlo simulation. Receiver operating characteristic (ROC) curves are used to compare performance in differentiating tumors relative to background based on the dynamic data sets. Using area under the ROC curve as a performance metric, we show superior performance of Patlak relative to % DSUV over a range of dynamic data sets and parameters. These results suggest that Patlak analysis may be appropriate for analysis of dual time-point whole body PET data and could lead to superior detection of tumors relative to % DSUV metrics.
引用
收藏
页码:913 / 924
页数:12
相关论文
共 50 条
  • [1] Dual-time-point Patlak estimation from list mode PET data
    Li, Quanzheng
    Zhu, Wentao
    Leahy, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [2] DUAL-TIME-POINT PATLAK ESTIMATION FROM LIST MODE PET DATA
    Zhu, Wentao
    Li, Quanzheng
    Leahy, Richard M.
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 486 - 489
  • [3] DIRECT ESTIMATION OF PATLAK PARAMETERS FROM LIST MODE PET DATA
    Li, Quanzheng
    Leahy, Richard M.
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 390 - 393
  • [4] An Efficient Implementation of PET Image Reconstruction from List-Mode Data
    Zhang Bin
    Shan Bao-ci
    Yun Ming-kai
    Zhao Shu-jun
    2012 INTERNATIONAL WORKSHOP ON INFORMATION AND ELECTRONICS ENGINEERING, 2012, 29 : 3403 - 3407
  • [5] Event-by-Event Image Reconstruction From List-Mode PET Data
    Schretter, Colas
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2009, 18 (01) : 117 - 124
  • [6] List-mode image reconstruction for real-time PET imaging
    Selivanov, Vitali V.
    Lepage, Martin D.
    Lecomte, Roger
    JOURNAL OF VISUAL COMMUNICATION AND IMAGE REPRESENTATION, 2006, 17 (03) : 630 - 646
  • [7] Spatiotemporal reconstruction of list-mode PET data
    Nichols, TE
    Qi, JY
    Asma, E
    Leahy, RM
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (04) : 396 - 404
  • [8] PyTomography: Advancements in List-mode and Time-of-Flight PET Image Reconstruction
    Polson, Luke
    Karakatsanis, Nicolas
    Uribe, Carlos
    Rahmim, Arman
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [9] Calculation of the sensitivity image in list-mode reconstruction for PET
    Qi, Jinyi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2746 - 2751
  • [10] Rapid processing of PET list-mode data for efficient uncertainty estimation and data analysis
    Markiewicz, P. J.
    Thielemans, K.
    Schott, J. M.
    Atkinson, D.
    Arridge, S. R.
    Hutton, B. F.
    Ourselin, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (13): : N322 - N336