Blood levels of cobalt and chromium are inversely correlated to head size after metal-on-metal resurfacing arthroplasty

被引:4
|
作者
Parry, Michael C. [1 ]
Eastaugh-Waring, Steve [1 ]
Bannister, Gordon C. [1 ]
Learmonth, Ian D. [1 ]
Case, Charles Patrick [1 ]
Blom, Ashley W. [1 ]
机构
[1] Southmead Hosp, Musculoskeletal Res Unit, Univ Dept Orthopaed Surg, Avon Orthopaed Ctr, Bristol BS10 5NB, Avon, England
关键词
Metal-on-metal; Resurfacing arthroplasty; Hip replacement; TOTAL HIP; SURFACE REPLACEMENT; DNA-DAMAGE; ION LEVELS; FOLLOW-UP; FAILURE; YOUNGER;
D O I
10.5301/hipint.5000057
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Resurfacing arthroplasty has fallen out of favour in recent years due to unfavourable survivorship in joint registries and alarming reports of soft tissue reactions around metal on metal prostheses. Our aim was to assess the effect of head size, implant design and component positioning on metal production by resurfacing arthroplasties. We measured whole blood cobalt and chromium and component position in matched populations implanted with two designs of resurfacing arthroplasty over a two-year period. Both implants resulted in a significant increase in blood metal levels (p<0.001) though the ASR design generated significantly higher metal levels (p = 0.041). A significant inverse correlation was seen between component size and blood cobalt levels (p = 0.032) and blood chromium levels (p<0.001). No correlation was identified between component position and blood metal levels. Small diameter metal resurfacing components result in increased metal generation compared with larger components. As increased metal generation has been correlated to wear and therefore failure, caution must be used on implantation of smaller components and indeed, in those who require smaller components, alternative bearing materials should be considered. These results contrast with recent findings which have demonstrated early failure for larger diameter stemmed metal-on-metal prostheses.
引用
收藏
页码:529 / 534
页数:6
相关论文
共 50 条
  • [1] How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing?
    Vendittoli, Pascal-A
    Lavigne, Martin
    Roy, Alain-Guy
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (451) : 292 - 293
  • [2] How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing?
    Back, DL
    Young, AA
    Shimmin, AJ
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (438) : 177 - 181
  • [3] Changes in Cobalt and Chromium Levels After Metal-on-Metal Hip Resurfacing in Young, Active Chinese Patients
    Yang, Jing
    Shen, Bin
    Zhou, ZongKe
    Pei, Fuxing
    Kang, PengDe
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (01): : 65 - 70
  • [4] The exercise-related rise in plasma cobalt levels after metal-on-metal hip resurfacing arthroplasty
    Khan, M.
    Kuiper, J. -H.
    Richardson, J. B.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (09): : 1152 - 1157
  • [5] How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing? Reply
    Back, D. L.
    Young, D. A.
    Shimmin, A.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (451) : 293 - 293
  • [6] A tribological study of cobalt chromium molybdenum alloys used in metal-on-metal resurfacing hip arthroplasty
    Cawley, J
    Metcalf, JEP
    Jones, AH
    Band, TJ
    Skupien, DS
    [J]. WEAR, 2003, 255 : 999 - 1006
  • [7] Complications After Metal-on-Metal Hip Resurfacing Arthroplasty
    Amstutz, Harlan C.
    Le Duff, Michel J.
    Campbell, Patricia A.
    Wisk, Lauren E.
    Takamura, Karren M.
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 2011, 42 (02) : 207 - +
  • [8] Metal Presence in Hair After Metal-on-Metal Resurfacing Arthroplasty
    Rodriguez de la Flor, Maria
    Hernandez-Vaquero, Daniel
    Manuel Fernandez-Carreira, Jose
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (12) : 2025 - 2031
  • [9] Metal ion levels in a triathlete with a metal-on-metal resurfacing arthroplasty of the hip
    De Haan, R.
    Campbell, P.
    Reid, S.
    Skipor, A. K.
    De Smet, K.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (04): : 538 - 541
  • [10] Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty
    Witzleb, Wolf-Christoph
    Ziegler, Joerg
    Krummenauer, Frank
    Neumeister, Volker
    Guenther, Klaus-Peter
    [J]. ACTA ORTHOPAEDICA, 2006, 77 (05) : 697 - 705