Treating cuff tear arthropathy by reverse total shoulder arthroplasty: do the inclination of the humeral component and the lateral offset of the glenosphere influence the clinical and the radiological outcome?

被引:9
|
作者
Holschen, Malte [1 ,2 ]
Kiriazis, Alexandros [1 ]
Bockmann, Benjamin [3 ]
Schulte, Tobias L. [3 ]
Witt, Kai-Axel [1 ]
Steinbeck, Jorn [1 ]
机构
[1] Orthoped Practice Clin OPPK, Schuerbusch 55, D-48143 Munster, Germany
[2] Raphaelsklin, Munster, Germany
[3] Ruhr Univ Bochum, St Josef Hosp, Dept Orthoped & Trauma Surg, Bochum, Germany
关键词
Reverse total shoulder arthroplasty; Shoulder replacement; Scapular notching; Humeral inclination; Lateral offset; Center of rotation; NECK-SHAFT ANGLE; FOLLOW-UP; RANGE; IMPINGEMENT; ABDUCTION; ROTATION; DESIGN; IMPACT; MOTION;
D O I
10.1007/s00590-021-02976-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeReverse total shoulder arthroplasty is widely used for the treatment of cuff tear arthropathy. Standard implants consist of a humeral component with an inclination angle of 155 degrees and a glenosphere without lateral offset. Recently, lower inclination angles of the humeral component as well as lateralized glenospheres are implanted to provide better rotation of the arm and to decrease the rate of scapular notching. This study investigates the clinical and radiological results of a standard reverse total shoulder in comparison with an implant with an inclination angle of 135 degrees in combination with a 4 mm lateralized glenosphere in context of cuff tear arthropathy. Material and methodsFor this retrospective comparative analysis 42 patients treated by reverse total shoulder arthroplasty for cuff tear arthropathy were included. Twenty-one patients (m=11, f=10; mean age 76 years; mean follow-up 42 months) were treated with a standard 155 degrees humeral component and a standard glenosphere with caudal eccentricity (group A), while twenty-one patients (m=5, f=16; mean age 72 years; mean follow-up 34 months) were treated with a 135 degrees humeral component and 4 mm lateral offset of the glenosphere (group B). At follow-up patients of both groups were assessed with plain X-rays (a.p. and axial view), Constant Score, adjusted Constant Score, the subjective shoulder value and the range of motion. ResultsThe clinical results were similar in both groups concerning the Constant Score (group A=56.3 vs. group B=56.1; p=0.733), the adjusted CS (group A=70.4% vs. group B=68.3%; p=0.589) and the SSV (group A=72.0% vs. group B=75.2%; p=0.947). The range of motion of the operated shoulders did not differ significantly between group A and group B: Abduction=98 degrees versus 97.9 degrees, p=0.655; external rotation with the arm at side=17.9 degrees versus 18.7 degrees, p=0.703; external rotation with the arm positioned in 90 degrees of abduction=22.3 degrees versus 24.7 degrees, p=0.524; forward flexion=116.1 degrees versus 116.7 degrees, p=0.760. The rate of scapular notching was higher (p=0.013) in group A (overall: 66%, grade 1: 29%, grade 2: 29%, grade 3: 10%, grade 4: 0%) in comparison to group B (overall: 33%, grade 1: 33%, grade 2: 0%, grade 3: 0%, grade 4: 0%). Radiolucency around the humeral component was detected in two patients of group B. Stress shielding at the proximal humerus was observed in six patients of Group A (29%; cortical thinning and osteopenia in zone M1 and L1) and two patients of group B (10%; cortical thinning and osteopenia in zone M1 and L1). Calcifications of the triceps origin were observed in both groups (group A=48% vs. group B=38%). ConclusionTheoretically, a lower inclination angle of the humeral component and an increased lateral offset of the glenosphere lead to improved impingement-free range of motion and a decreased rate of scapular notching, when compared to a standard reverse total shoulder implant. This study compared two different designs of numerous options concerning the humeral component and the glenosphere. In comparison to a standard-fashioned implant with a humeral inclination of 155 degrees and a standard glenosphere, implants with a humeral inclination angle of 135 degrees and a 4 mm lateralized glenosphere lead to comparable clinical results and rotatory function, while the rate of scapular notching is decreased by almost 50%. While the different implant designs did not affect the clinical outcome, our results indicate that a combination of a lower inclination angle of the humeral component and lateralized glenosphere should be favored to reduce scapular notching.Level of evidenceLevel III, retrospective comparative study
引用
收藏
页码:307 / 315
页数:9
相关论文
共 50 条
  • [1] Treating cuff tear arthropathy by reverse total shoulder arthroplasty: do the inclination of the humeral component and the lateral offset of the glenosphere influence the clinical and the radiological outcome?
    Malte Holschen
    Alexandros Kiriazis
    Benjamin Bockmann
    Tobias L. Schulte
    Kai-Axel Witt
    Jörn Steinbeck
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 307 - 315
  • [2] Treatment of proximal humerus fractures using reverse shoulder arthroplasty: do the inclination of the humeral component and the lateral offset of the glenosphere influence the clinical outcome and tuberosity healing?
    Holschen, Malte
    Koerting, Maria
    Khourdaji, Patrick
    Bockmann, Benjamin
    Schulte, Tobias L.
    Witt, Kai-Axel
    Steinbeck, Joern
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (12) : 3817 - 3826
  • [3] Treatment of proximal humerus fractures using reverse shoulder arthroplasty: do the inclination of the humeral component and the lateral offset of the glenosphere influence the clinical outcome and tuberosity healing?
    Malte Holschen
    Maria Körting
    Patrick Khourdaji
    Benjamin Bockmann
    Tobias L. Schulte
    Kai-Axel Witt
    Jörn Steinbeck
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 3817 - 3826
  • [4] Effects of humeral component retroversion on functional outcomes in reverse total shoulder arthroplasty for cuff tear arthropathy
    Rhee, Yong Girl
    Cho, Nam Su
    Moon, Seong Cheol
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (10) : 1574 - 1581
  • [5] Reverse Total Shoulder Arthroplasty Improves Function in Cuff Tear Arthropathy
    Nolan, Betsy M.
    Ankerson, Elizabeth
    Wiater, J. Michael
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (09) : 2476 - 2482
  • [6] Reverse Total Shoulder Arthroplasty for Irreparable Rotator Cuff Tears and Cuff Tear Arthropathy
    Ramirez, Miguel A.
    Ramirez, Jose
    Murthi, Anand M.
    CLINICS IN SPORTS MEDICINE, 2012, 31 (04) : 749 - +
  • [7] Managing rotator cuff tear arthropathy: a role for cuff tear arthropathy hemiarthroplasty as well as reverse total shoulder arthroplasty
    Stenson, James F.
    Mills, Zachary D.
    Dasari, Suhas P.
    Whitson, Anastasia J.
    Hsu, Jason E.
    Matsen, Frederick A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2024, 33 (03) : e162 - e174
  • [8] Functional outcome of hemiarthroplasty compared with reverse total shoulder arthroplasty in the treatment of rotator cuff tear arthropathy
    Leung, Brian
    Horodyski, MaryBeth
    Struk, Aimee M.
    Wright, Thomas W.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (03) : 319 - 323
  • [9] Deltoid muscle volume affects clinical outcome of reverse total shoulder arthroplasty in patients with cuff tear arthropathy or irreparable cuff tears
    Yoon, Jong Pil
    Seo, Anna
    Kim, Jeong Jun
    Lee, Chang-Hwa
    Baek, Seung-Hun
    Kim, Shin Yoon
    Jeong, Eun Taek
    Oh, Kyung-Soo
    Chung, Seok Won
    PLOS ONE, 2017, 12 (03):
  • [10] Reverse total shoulder arthroplasty: Radiological and clinical result using an eccentric glenosphere
    De Biase C.F.
    Delcogliano M.
    Borroni M.
    Castagna A.
    MUSCULOSKELETAL SURGERY, 2012, 96 (Suppl 1) : S27 - S34