Use of heparin-coated stents in neurovascular interventional procedures: Preliminary experience with 10 patients

被引:58
|
作者
Parkinson, Richard J.
Demers, Christopher P.
Adel, Joseph G.
Levy, Elad I.
Sauvageau, Eric
Hanel, Ricardo A.
Shaibani, Ali
Guterman, Lee R.
Hopkins, L. Nelson
Batjer, H. Hunt
Bendok, Bernard R.
机构
[1] Northwestern Univ, Dept Neurol Surg & Radiol, Feinberg Sch Med, Chicago, IL 60611 USA
[2] Brown Univ, Sch Med, Dept Neurosurg, Providence, RI 02912 USA
[3] St Vincents Clin, Dept Neurosurg, Sydney, NSW, Australia
[4] SUNY Buffalo, Dept Neurosurg, Sch Med & Biomed Sci, Buffalo, NY 14260 USA
[5] SUNY Buffalo, Dept Radiol, Sch Med & Biomed Sci, Buffalo, NY 14260 USA
[6] Buffalo Neurosurg Grp, Dept Neurosurg, W Seneca, NY USA
[7] SUNY Buffalo, Sch Med & Biomed Sci, Toshiba Stroke Res Ctr, Buffalo, NY 14260 USA
关键词
heparin-coated stents; intracranial atherosclerosis; percutaneous transluminal angioplasty and stenting;
D O I
10.1227/01.NEU.0000232836.66310.46
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: Currently, there is minimal published data on the use of heparin-coated stents in the neurovasculature; however, these stents have a proven clinical record in the treatment of coronary disease. This article details our experience with the safety and technical aspects of stent deployment in the first 10 patients who had heparin-coated stents placed in the intracranial and cervical vasculature and the preliminary follow-up in most cases. METHODS: We retrospectively reviewed the clinical history, intra- and periprocedural data, and imaging for the patients who received heparin-coated stents in the cervical and intracranial vasculature for cerebrovascular disease between October 2002 and October 2003. RESULTS: Thirteen heparin-coated stents were placed in 10 patients. Seven out of the 10 patients had heparin-coated stents placed in the posterior circulation; the remaining three patients had stents placed in the anterior circulation. Four patients had stents placed intracranially. There was no acute or subacute in-stent thrombosis and no procedure-related complications. Follow-up was performed on most patients, with no clinical symptoms attributable to restenosis in any patient. CONCLUSION: This small series suggests that heparin-coated stents are safe for use in the treatment of cervical and intracranial atherosclerotic disease. Longer-term follow-up is needed to study the heparin coating effect on in-stent restenosis rates and to assess the long-term durability and clinical efficacy of this stent. The use of drug-coated stents in the cerebrovascular circulation is an area that warrants further investigation.
引用
收藏
页码:812 / 821
页数:10
相关论文
共 50 条
  • [1] Use of heparin-coated stents in neurovascular interventional procedures: Preliminary experience with 10 patients - Comments
    Rosenwasser, Robert H.
    Albuquerque, Felipe C.
    Prestigiacomo, Charles J.
    NEUROSURGERY, 2006, 59 (04) : 821 - 821
  • [2] Heparin-coated stents
    Kocsis, JF
    Llanos, G
    Holmer, E
    JOURNAL OF LONG-TERM EFFECTS OF MEDICAL IMPLANTS, 2000, 10 (1-2) : 19 - 45
  • [3] Heparin-coated stents in patients with acute coronary syndromes (HEPACIS).
    Wójcik, J
    Drozd, J
    Madejczyk, A
    Widomska-Czekajska, T
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (8A): : 8I - 9I
  • [4] HEPARIN-COATED VASCULAR SHUNT FOR THORACIC AORTIC AND GREAT VESSEL PROCEDURES - 10-YEAR EXPERIENCE
    DONAHOO, JS
    BRAWLEY, RK
    GOTT, VL
    ANNALS OF THORACIC SURGERY, 1977, 23 (06): : 507 - 513
  • [5] Use of heparin-coated stents to reduce subacute stent thrombosis: Outcome in "real-world" patients
    Gupta, V
    Fischell, TA
    Aravamuthan, BR
    Lauer, MA
    Smith, SK
    Gupta, V
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (6A): : 7H - 7H
  • [6] USE OF HEPARIN-COATED CARDIOPULMONARY BYPASS
    JONES, DR
    HILL, RC
    HOLLINGSED, MJ
    STULLKEN, E
    GRAEBER, GM
    GUSTAFSON, RA
    MURRAY, GF
    ANNALS OF THORACIC SURGERY, 1993, 56 (03): : 556 - 558
  • [7] PREVENTION OF (SUB)ACUTE THROMBOSIS USING HEPARIN-COATED STENTS
    VANDERGIESSEN, WJ
    HARDHAMMAR, PA
    VANBEUSEKOM, HMM
    EMANUELSSON, HU
    TANG, ZH
    VERDOUW, PD
    SERRUYS, PW
    CIRCULATION, 1994, 90 (04) : 650 - 650
  • [8] Heparin-coated stents in small coronary arteries - Results of the COAST trial
    Haude, M
    Konorza, T
    Kalnins, U
    Glogar, D
    Gill, R
    Serra, A
    Erbel, R
    Grube, E
    EUROPEAN HEART JOURNAL, 2002, 23 : 265 - 265
  • [9] Heparin-coated Wiktor stents in human coronary arteries (MENTOR trial)
    Vrolix, MCM
    Legrand, VM
    Reiber, JHC
    Grollier, G
    Schalij, MJ
    Brunel, P
    Martinez-Elbal, L
    Gomez-Recio, M
    Bär, FWHM
    Bertrand, ME
    Colombo, A
    Brachman, J
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (04): : 385 - 389
  • [10] Platelet activation after stenting with heparin-coated versus noncoated stents
    Gurbel, PA
    Bliden, KP
    Hiatt, BL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 13A - 13A