Nitrogen washout/washin, helium dilution and computed tomography in the assessment of end expiratory lung volume (vol 12, pg R150, 2008)

被引:2
|
作者
Chiumello, Davide [1 ]
Cressoni, Massimo [2 ,3 ]
Chierichetti, Monica [2 ,3 ]
Tallarini, Federica [2 ,3 ]
Botticelli, Marco [2 ,3 ]
Berto, Virna [2 ,3 ]
Mietto, Cristina [2 ,3 ]
Gattinoni, Luciano [1 ,2 ,3 ]
机构
[1] Osped Maggiore, Policlin Mangiagalli Regina Elena, Dipartimento Anestesia Rianimaz Intens & Subinten, Fdn IRCCS, I-20122 Milan, Italy
[2] Osped Maggiore, Policlin Mangiagalli Regina Elena, Ist Anestesiol & Reanimaz, Fdn IRCCS, I-20122 Milan, Italy
[3] Univ Milan, I-20122 Milan, Italy
来源
CRITICAL CARE | 2009年 / 13卷 / 02期
关键词
D O I
10.1186/cc7743
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
引用
收藏
页数:4
相关论文
共 15 条
  • [1] Nitrogen washout/washin, helium dilution and computed tomography in the assessment of end expiratory lung volume
    Davide Chiumello
    Massimo Cressoni
    Monica Chierichetti
    Federica Tallarini
    Marco Botticelli
    Virna Berto
    Cristina Mietto
    Luciano Gattinoni
    Critical Care, 12
  • [2] Nitrogen washout/washin, helium dilution and computed tomography in the assessment of end expiratory lung volume
    Chiumello, Davide
    Cressoni, Massimo
    Chierichetti, Monica
    Tallarini, Federica
    Botticelli, Marco
    Berto, Virna
    Mietto, Cristina
    Gattinoni, Luciano
    CRITICAL CARE, 2008, 12 (06):
  • [3] Erratum to: Nitrogen washout/washin, helium dilution and computed tomography in the assessment of end expiratory lung volume
    Davide Chiumello
    Massimo Cressoni
    Monica Chierichetti
    Federica Tallarini
    Marco Botticelli
    Virna Berto
    Cristina Mietto
    Luciano Gattinoni
    Critical Care, 13
  • [4] Nitrogen washout/washin, helium dilution, and computed tomography in the assessment of end-expiratory lung volume
    Richard, Jean Christophe
    Guerin, Claude
    CRITICAL CARE, 2013, 17 (05):
  • [5] Nitrogen washout/washin, helium dilution, and computed tomography in the assessment of end-expiratory lung volume
    Jean Christophe Richard
    Claude Guerin
    Critical Care, 17
  • [6] ASSESSMENT OF TRENDING ABILITY OF THE NITROGEN WASHOUT-WASHIN TECHNIQUE TO DETECT CHANGE IN END-EXPIRATORY LUNG VOLUME
    Richard, J-C
    Pouzot, C.
    Morales, A.
    Torres, J. S.
    Munoz, D. Ortega
    Orkisz, M.
    Neyran, B.
    Lavenne, F.
    Guerin, C.
    INTENSIVE CARE MEDICINE, 2013, 39 : S495 - S495
  • [7] Accuracy of the end-expiratory lung volume measured by the modified nitrogen washout/washin technique: a bench study
    Joana Berger-Estilita
    Matthias Haenggi
    Daniel Ott
    David Berger
    Journal of Translational Medicine, 19
  • [8] Accuracy of the end-expiratory lung volume measured by the modified nitrogen washout/washin technique: a bench study
    Berger-Estilita, Joana
    Haenggi, Matthias
    Ott, Daniel
    Berger, David
    JOURNAL OF TRANSLATIONAL MEDICINE, 2021, 19 (01)
  • [9] Reliability of the nitrogen washin-washout technique to assess end-expiratory lung volume at variable PEEP and tidal volumes
    Richard J.-C.
    Pouzot C.
    Pinzón A.M.
    González J.S.T.
    Orkisz M.
    Neyran B.
    Hoyos M.H.
    Lavenne F.
    Guerin C.
    Intensive Care Medicine Experimental, 2 (1)
  • [10] Quantification of changes in end expiratory lung volume using electric impedance tomography, N2 washout/washin and cumulative inspiratory-expiratory tidal volume differences
    Grivans, C.
    Lindgren, S.
    Lundin, S.
    Stenqvist, O.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2009, 53 : 53 - 53