Study of the annealing effect on silicon microstrip detectors built on ⟨111⟩ and ⟨100⟩ substrates after 34 MeV proton irradiation

被引:1
|
作者
Creanza, D
Giordano, D
de Palma, M
Fiore, L
Manna, N
My, S
Radicci, V
Tempesta, P
机构
[1] Ist Nazl Fis Nucl, Sez Bari, I-70126 Bari, Italy
[2] Ist Nazl Fis Nucl, Dipartimento Interateneo Fis, I-70126 Bari, Italy
关键词
silicon detector; crystal orientation; proton irradiation; annealing;
D O I
10.1016/j.nima.2004.05.059
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The behaviour of the leakage current, interstrip resistance and capacitance have been studied on silicon microstrip detectors during an annealing period equivalent to similar or equal to 10(8) min at room temperature, after 34 MeV proton irradiation. A comparison between samples of the same geometry built on < 1 0 0 > and < 1 1 1 > substrates with different resistivity has been carried out. The samples were irradiated at 4 different fluences up to 1 X 10(14) p/cm(2). After the irradiation the measurements were performed at room temperature and after heating the samples at 60degreesC, 80degreesC and 120degreesC to cover the complete annealing curve. The leakage current shows the same annealing behaviour typical of a simple diode. The interstrip resistance measured at full depletion voltage (V-dep) decreases in all structures, going down to few tens of MOmega at the highest fluence. It remains practically constant during the annealing period. The interstrip capacitance (at V-dep) varies during the annealing period with the same behaviour in both substrates and for all the fluence values: it decreases during the annealing at room temperature, reaching a minimum value, and increases after each heat treatment. Bistable defects seem to contribute to the interstrip capacitance variation. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:122 / 127
页数:6
相关论文
共 12 条
  • [1] A comparison on radiation tolerance of ⟨100⟩ and ⟨111⟩ silicon substrates of microstrip detectors
    Calefato, G
    Creanza, D
    de Palma, M
    Fiore, L
    My, S
    Radicci, V
    Selvaggi, G
    Tempesta, P
    Angarano, MM
    Bilei, GM
    Biasini, M
    Giorgi, M
    Militaru, O
    Servoli, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (03): : 744 - 750
  • [2] A comparison on radiation tolerance of microstrip detectors built on ⟨1 0 0⟩ and ⟨1 1 1⟩ silicon substrates after proton irradiation
    Creanza, D
    Giordano, D
    de Palma, M
    Fiore, L
    My, S
    Radicci, V
    Selvaggi, G
    Tempesta, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 485 (1-2): : 109 - 115
  • [3] Annealing at Different Temperatures of Silicon Microstrip Detectors After Severe Hadron Irradiation
    Casse, Gianluigi
    Affolder, Anthony
    Allport, Philip P.
    Chmill, Valery
    Forshaw, Dean
    Greenall, Ashley
    Huse, Torkjell
    Tsurin, Ilya
    Wormald, Michael
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (02) : 419 - 424
  • [4] Deep-level transient spectroscopy studies of silicon detectors after 24 GeV proton irradiation and 1 MeV neutron irradiation
    Ahmed, M
    Watts, SJ
    Matheson, J
    Holmes-Siedle, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 457 (03): : 588 - 594
  • [5] Performances of miniature microstrip detectors made on oxygen enriched p-type substrates after very high proton irradiation
    Casse, G
    Allport, PP
    Garcia, SMI
    Lozano, M
    Turner, PR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 535 (1-2): : 362 - 365
  • [6] Comparison of the radiation hardness of Magnetic Czochralski and Epitaxial silicon substrates after 26 MeV proton and reactor neutron irradiation
    Creanza, D.
    Bassignana, D.
    Borrello, L.
    Boscardin, M.
    Bruzzi, M.
    de Palma, M.
    Focardi, E.
    Macchiolo, A.
    Manna, N.
    Menichelli, D.
    Messineo, A.
    Piemonte, C.
    Pozza, A.
    Radicci, V.
    Scaringella, M.
    Zorzi, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (02): : 608 - 613
  • [7] Study of bistable defects created after high-temperature annealing in 34 MeV proton irradiated Si diodes
    Creanza, D
    Giordano, D
    de Palma, M
    Fiore, L
    Manna, N
    My, S
    Radicci, V
    Tempesta, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 530 (1-2): : 128 - 133
  • [8] The effect of oxygen impurities on radiation hardness of FZ silicon detectors for HEP after neutron, proton and gamma irradiation
    Dezillie, B
    Li, Z
    Eremin, V
    Chen, W
    Zhao, LJ
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 800 - 805
  • [9] The effect of oxygen impurities on radiation hardness of FZ silicon detectors for HEP after neutron, proton and gamma irradiation
    Dezillie, B
    Li, Z
    Eremin, V
    Chen, W
    Zhao, LJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (06) : 1892 - 1897
  • [10] Effects of accelerated annealing on p-type silicon micro-strip detectors after very high doses of proton irradiation
    Casse, G.
    Allport, P. P.
    Watson, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (01): : 46 - 50