Behaviour and speciation of inorganic trace pollutants in a coal-fired power plant equipped with DENOX-SCR-ESP-NH3FGD controls

被引:6
|
作者
Cordoba, Patricia [1 ]
Li, Baoqing [2 ]
Li, Jing [2 ]
Shangguan, Yunfei [2 ]
Trechera, Pedro [1 ]
Zhuang, Xinguo [2 ]
Querol, Xavier [1 ]
机构
[1] Spanish Natl Res Council, Inst Environm Assessment & Water Res IDAEA, CSIC, C Jordi Girona 18-26, Barcelona 08034, Spain
[2] China Univ Geosci, Key Lab Tecton & Petr Resources, Minist Educ, Wuhan 430074, Peoples R China
关键词
Selective reduction catalyst (SCR); Ammonia flue gas desulphurisation (NH3-FGD) (NH4)(2)SO4 slurry; Water re-circulation cycles; OUT-FGD gas; Ionic strength; ELEMENTAL MERCURY; WET FGD; OXIDATION; CATALYSTS; REMOVAL;
D O I
10.1016/j.fuel.2020.119927
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The behaviour and speciation of inorganic trace pollutants were studied in a 270 MWh coal-fired power station equipped with denitrification (DeNOx)-based selective catalytic reduction (SCR), electrostatic precipitators (ESP) and ammonia flue gas desulphurisation (NH3-FGD) controls. The aqueous (NH4)(2)SO4 slurry (pH 3.2) showed remarkably high concentrations of SO42-, Cl-, Fe, NH4+, PO43-, and F- and was substantially enriched in multiple trace pollutants, e.g. Mn, Ni, Zn, and As, which can be ascribed to the diffusion of gaseous pollutants released during combustion and to the partial dissolution of fly ash (FA) particles entrained in the flue gas FGD. These processes were favoured by the iteration of the FGD water re-circulation cycles within the scrubber. Three major unresolved performance issues remain for the NH3-FGD with respect to the retention efficiency of major and trace pollutants: (i) the high concentration of soluble salts and major and minor trace elements in the aqueous (NH4)(2)SO4 slurry could lead to entrainment of droplets and particles with the outgoing (OUT)-FGD gas; (ii) the ionic strength, as a result of the high concentration of the elements associated with soluble salts and major and minor elements, could lead to diminishing diffusivity of gaseous pollutants into the aqueous phase, where these are supposed to dissolve; and (iii) the acidic conditions of the aqueous (NH4)(2)SO4 slurry, caused by Fe-hydrolysis, could lead to low FGD efficiencies. Operating conditions at this power station affect Hg partitioning and fate across the PCC-SCR-ESP-NH3-FGD.
引用
收藏
页数:10
相关论文
共 32 条
  • [1] Distribution characteristics of particulate matter at the inlet of SCR, ESP and FGD in a coal-fired power plant boiler
    Pan, Fengping
    Chen, Huazhong
    Pang, Zhiqiang
    Wang, Chao
    Si, Junping
    Liu, Xiaowei
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2014, 34 (32): : 5728 - 5733
  • [2] The emissions and environmental impact of PM10 and trace elements from a modern coal-fired power plant equipped with ESP and wet FGD
    Meij, R
    Winkel, HT
    FUEL PROCESSING TECHNOLOGY, 2004, 85 (6-7) : 641 - 656
  • [3] Optimization Simulation of Ammonia Injection in SCR DeNOx System of Coal-Fired Power Plant
    Lu Z.
    Li B.
    Tang W.
    Chen Y.
    Wu K.
    Yao S.
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2023, 51 (08): : 62 - 70
  • [4] Discussion about SCR DeNOX Technology Applied in Large Coal-fired Power Plant
    刘国华
    张江洪
    陈丽娟
    河南工学院学报, 2008, (03) : 87 - 89
  • [5] DeNOx performance of SCR catalyst for exhaust gas from coal-fired power plant
    School of Energy and Power Engineering, Shandong University, Jinan 250061, Shandong, China
    Huagong Xuebao, 2013, 7 (2611-2618):
  • [6] A Multiple Model Control Method of Coal-Fired Power Plant SCR-DeNOx System
    Zhang, Jianhua
    Jia, Bin
    Zou, Ben
    Tian, Xiao
    Liu, Chunyao
    ADVANCES IN GREEN ENERGY SYSTEMS AND SMART GRID, PART III, 2018, 925 : 306 - 313
  • [7] Large eddy simulation of hydrodynamics and deNOx process in a coal-fired power plant SCR system
    Zhou, Zhijian
    Chang, Jian
    Wang, Xin
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2022, 320
  • [8] Partitioning of trace inorganic elements in a coal-fired power plant equipped with a wet Flue Gas Desulphurisation system
    Cordoba, Patricia
    Ochoa-Gonzalez, Raquel
    Font, Oriol
    Izquierdo, Maria
    Querol, Xavier
    Leiva, Carlos
    Antonia Lopez-Anton, Maria
    Diaz-Somoano, Mercedes
    Rosa Martinez-Tarazona, M.
    Fernandez, Constantino
    Tomas, Alfredo
    FUEL, 2012, 92 (01) : 145 - 157
  • [9] CFD Simulation and Optimization of SCR DeNOx System in a 660MW Coal-fired Power Plant
    Zhou Z.
    Wang X.
    Chang J.
    Chen H.
    Niu Y.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (19): : 6688 - 6698
  • [10] CFD Simulations of Gate Leaves Design in The SCR-DeNOx Facility for Coal-Fired Power Plant
    Xu Yuanyuan
    Jin Qiang
    Yuan Jingqi
    2011 30TH CHINESE CONTROL CONFERENCE (CCC), 2011, : 5868 - 5872