Eight-year clinical evaluation of two types of resin composite in non-carious cervical lesions (Jun, 10.1007/s00784-022-04587-7, 2022)

被引:1
|
作者
Kaida, Kei [1 ]
Kubo, Shisei [1 ]
Egoshi, Takafumi [1 ]
Taira, Yohsuke [1 ]
机构
[1] Nagasaki Univ, Grad Sch Biomed Sci, Div Cariol & Restorat Dent, 1-7-1 Sakamoto, Nagasaki 8528588, Japan
基金
日本学术振兴会;
关键词
Analytical observational study; Flowable resin composite; Non-carious cervical lesions; One-step self-etch adhesive;
D O I
10.1007/s00784-022-04621-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: In this clinical study, the 8-year clinical performances of a flowable resin composite was compared with that of a conventional resin composite. Materials and methods: Ninety non-carious cervical lesions (NCCLs) in 19 participants were involved in this trial. NCCLs were restored with a flowable composite (Clearfil Flow FX: FX, Kuraray Noritake, Japan) or a conventional resin composite (Clearfil AP-X: AP) in conjunction with a one-step self-etch adhesive (Clearfil S3 Bond). Each participant had both types of resin composite restorations that were randomly allocated. The restorations were evaluated at baseline and annually up to 8 years using modified USPHS criteria. The data were statistically analyzed using the Fisher’s exact test, Kaplan–Meier method, and a multivariate Cox-regression with frailty models (p < 0.05). Results: The 8-year participant recall rate was 95%. One hundred percent retention was recorded for AP, whereas four out of 46 restorations were lost for FX during the 8 years. The incidence of marginal staining increased over time regardless of the type of resin composite, showing 48% for AP and 57% for FX after 8 years. Wear of the resin composite occurred only for the flowable material and there was a significant difference between the types of resin composite (p = 0.024). Overall survival rates at 8 years for AP and FX were 98% and 82% respectively (p = 0.110). Conclusions: The flowable resin composite presented lower wear resistance and showed a lower survival rate compared with the conventional composite after eight years of clinical service. Clinical relevance: Flowable resin composites may show greater wear after long-term clinical service. Trial registration number: UMIN000028745, Date of registration: August 19, 2017. © 2022, The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
引用
收藏
页码:6339 / 6339
页数:1
相关论文
共 30 条
  • [1] Eight-year clinical evaluation of two types of resin composite in non-carious cervical lesions
    Kei Kaida
    Shisei Kubo
    Takafumi Egoshi
    Yohsuke Taira
    [J]. Clinical Oral Investigations, 2022, 26 : 6327 - 6337
  • [2] Correction to: Eight‑year clinical evaluation of two types of resin composite in non‑carious cervical lesions
    Kei Kaida
    Shisei Kubo
    Takafumi Egoshi
    Yohsuke Taira
    [J]. Clinical Oral Investigations, 2022, 26 : 6339 - 6339
  • [3] Two-year clinical evaluation of composite resins in non-carious cervical lesions
    Qin, Wei
    Song, Zhi
    Ye, Yun-Yao
    Lin, Zheng-Mei
    [J]. CLINICAL ORAL INVESTIGATIONS, 2013, 17 (03) : 799 - 804
  • [4] Two-year clinical evaluation of composite resins in non-carious cervical lesions
    Wei Qin
    Zhi Song
    Yun-Yao Ye
    Zheng-Mei Lin
    [J]. Clinical Oral Investigations, 2013, 17 : 799 - 804
  • [5] Three-year clinical evaluation of a flowable and a hybrid resin composite in non-carious cervical lesions
    Kubo, Shisei
    Yokota, Hiroaki
    Yokota, Haruka
    Hayashi, Yoshihiko
    [J]. JOURNAL OF DENTISTRY, 2010, 38 (03) : 191 - 200
  • [6] Two-year Clinical Effectiveness of Adhesives and Retention Form on Resin Composite Restorations of Non-carious Cervical Lesions
    Kim, S-Y
    Lee, K-W
    Seong, S-R
    Lee, M-A
    Lee, I-B
    Son, H-H
    Kim, H-Y
    Oh, M-H
    Cho, B-H
    [J]. OPERATIVE DENTISTRY, 2009, 34 (05) : 507 - 515
  • [7] Five-year clinical evaluation of two adhesive systems in non-carious cervical lesions
    Kubo, S
    Kawasaki, K
    Yokota, H
    Hayashi, Y
    [J]. JOURNAL OF DENTISTRY, 2006, 34 (02) : 97 - 105
  • [8] Clinical evaluation of flowable resins in non-carious cervical lesions:: Two-year results
    Celik, C.
    Ozgunaltay, G.
    Attar, N.
    [J]. OPERATIVE DENTISTRY, 2007, 32 (04) : 313 - 321
  • [9] Two-year clinical evaluation of three adhesive systems in non-carious cervical lesions
    Dalkilic, Evrim Eliguzeloglu
    Omurlu, Huma
    [J]. JOURNAL OF APPLIED ORAL SCIENCE, 2012, 20 (02) : 192 - 199
  • [10] Clinical Evaluation of a Nanohybrid and a Flowable Resin Composite in Non-carious Cervical Lesions: 24-Month Results
    Karaman, Emel
    Yazici, A. Ruya
    Ozgunaltay, Gui
    Dayangac, Berrin
    [J]. JOURNAL OF ADHESIVE DENTISTRY, 2012, 14 (05): : 485 - 492