The Association of Pretransplant HeartMate II Left Ventricular Assist Device Placement and Heart Transplantation Mortality

被引:18
|
作者
Donneyong, Macarius [1 ]
Cheng, Allen [1 ]
Trivedi, Jaimin R. [1 ]
Schumer, Erin [1 ]
McCants, Kelly C. [2 ]
Birks, Emma J. [2 ]
Slaughter, Mark S. [1 ]
机构
[1] Univ Louisville, Med Ctr, Div Cardiovasc & Thorac Surg, Louisville, KY 40202 USA
[2] Univ Louisville, Med Ctr, Div Cardiol, Louisville, KY 40202 USA
关键词
heart transplantation; HeartMate; left ventricular assist device; mortality; MECHANICAL CIRCULATORY SUPPORT; CARDIAC TRANSPLANTATION; FAILURE; SELECTION; RECOVERY; REGISTRY; THERAPY; ERA;
D O I
10.1097/MAT.0000000000000065
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Previous United Network for Organ Sharing (UNOS) analysis has shown an increase in posttransplant mortality with pretransplant pulsatile-flow left ventricular assist device (LVAD). Recent studies evaluating continuous-flow LVAD demonstrated improved durability, excellent survival, and improved quality of life. This study investigates the association of preheart transplant continuous-flow LVAD placement and posttransplant mortality using the UNOS database. Heart transplant patients listed after April 2004 (N = 48,090) during the era of HeartMate (HM) II LVAD usage were investigated. Patients with UNOS 1A and 1B status with (n = 1,435) and without HMII (n = 16,379) placement before the heart transplantation were evaluated. Preliminary descriptive statistics suggested an extensive heterogeneity in patient characteristics between HMII LVAD recipients and nonrecipients. Propensity scores (1:2) were used to match HMII LVAD recipients and nonrecipients characteristics and donor characteristics. This resulted in a final sample of 2,265 patients (758 with HMII pretransplant placement and 1,507 without HMII pretransplant placement). The Kaplan-Meier curves were evaluated for the differences in postheart transplant mortality in patients with and without HMII pretransplant placement. A time-dependent Cox regression model was used to study the hazard ratios (HRs) for the association between HMII pretransplant placement and posttransplant survival. The mean age of the study group was 51.9 years old (standard deviation: 12.3). HeartMate II pretransplant placement was associated with no statistically significant difference in the risk of 30 days (HR = 1.23, 95% confidence interval [CI]: 0.79-1.95, p = 0.36) and 1 year posttransplant mortality (HR = 1.31, 95% CI: 0.85-2.01, p = 0.22) compared with non-HMII recipients. The use of HMII LVAD before heart transplantation, however, was associated with a statistically significant 64% lower risk (HR = 0.36, 95% CI: 0.16-0.77, p = 0.01) of mortality among heart transplant patients who survived beyond the first year of transplantation. Continuous-flow LVAD pretransplant placement is associated with improved long-term (>1 year) survival after heart transplantation.
引用
收藏
页码:294 / 299
页数:6
相关论文
共 50 条
  • [1] HeartMate left ventricular assist device as bridge to heart transplantation
    Koul, B
    Solem, JO
    Steen, S
    Casimir-Ahn, H
    Granfeldt, H
    Lönn, UJ
    [J]. ANNALS OF THORACIC SURGERY, 1998, 65 (06): : 1625 - 1630
  • [2] Optimal Timing of Heart Transplantation After HeartMate II Left Ventricular Assist Device Implantation
    Steffen, R. J.
    Blackstone, E. H.
    Smedira, N. G.
    Soltesz, E. G.
    Hoercher, K. J.
    Thuita, L.
    Starling, R. C.
    Mountis, M.
    Moazami, N.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S212 - S213
  • [3] HeartMate® II left ventricular assist device:: a new device for advanced heart failure
    Delgado, Reynolds
    Bergheim, Marianne
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2005, 2 (05) : 529 - 532
  • [4] Migration of a HeartMate II Left Ventricular Assist Device
    Jabbar, Ali Abdul
    Etheridge, Whitson B.
    Frazier, O. H.
    [J]. CIRCULATION-HEART FAILURE, 2013, 6 (03) : E30 - E30
  • [5] Repair of pectus excavatum during HeartMate II left ventricular assist device placement
    Tchantchaleishvili, Vakhtang
    Massey, Howard Todd
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 22 (01) : 118 - 120
  • [6] Prognostic value of left ventricular apical tissue removed for HeartMate II left ventricular assist device placement
    Soderlund, Karl A.
    Chivukula, Raghu R.
    Russell, Stuart D.
    Conte, John V.
    Mudd, James O.
    Halushka, Marc K.
    [J]. CARDIOVASCULAR PATHOLOGY, 2009, 18 (04) : 217 - 222
  • [7] Eosinophilic heart disease with vasculitis: Supported by HeartMate left ventricular assist device and heart transplantation
    Hsu, CP
    Chang, SH
    Wang, JS
    Shih, CC
    Lai, ST
    Yang, AH
    [J]. ANNALS OF THORACIC SURGERY, 2002, 73 (04): : 1307 - 1310
  • [8] Device exchange from HeartMate II to HeartMate 3 left ventricular assist device
    Takeda, Koji
    Takayama, Hiroo
    Sanchez, Joseph
    Cevasco, Marisa
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    Naka, Yoshifumi
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2019, 29 (03) : 430 - 433
  • [9] Exchange of a HeartMate II left ventricular assist device with a HeartMate 3 pump
    Hanke, Jasmin S.
    Haverich, Axel
    Schmitto, Jan D.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (07): : 944 - 946
  • [10] Left ventricular assist device therapy with the HeartMate II continuous flow rotary pump as a bridge to heart transplantation
    Pagani, Francis D.
    Miller, Leslie W.
    Russell, Stuart D.
    John, Ranjit
    Boyle, Andrew J.
    Aaronson, Keith D.
    Conte, John V.
    Naka, Yoshifumi
    Mancini, Donna
    Delgado, Reynolds M.
    MacGillivray, Thomas E.
    Farrar, David J.
    Frazier, O. H.
    [J]. CIRCULATION, 2007, 116 (16) : 540 - 541