Electrocardiographically gated multi-detector row CT for assessment of valvular morphology and calcification in aortic stenosis

被引:137
|
作者
Willmann, JK
Weishaupt, D
Lachat, M
Kobza, R
Roos, JE
Seifert, B
Lüscher, TF
Marincek, B
Hilfiker, PR
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Cardiovasc Surg Clin, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Clin Cardiol, CH-8091 Zurich, Switzerland
[4] Univ Zurich, Dept Biostat, Zurich, Switzerland
关键词
aortic valve; arteries; calcification; computed tomography (CT); multi-detector row;
D O I
10.1148/radiol.2251011703
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the applicability and image quality of nonenhanced and contrast material-enhanced multi-detector row computed tomography (CT) combined with retrospective electrocardiographic (ECG) gating for visualization of the aortic valve, determination of aortic valve morphology and diameter of the aortic valve annulus, and assessment of the degree of valvular calcification in patients with aortic valve stenosis, as compared with results of surgery and echocardiography. MATERIALS AND METHODS: Prior to surgical valve replacement, 25 patients with aortic valve stenosis and sinus rhythm underwent nonenhanced (n = 15) and contrast-enhanced (n = 25) retrospectively ECG-gated multi-detector row CT. Two readers working in consensus evaluated image quality and assessed valvular morphology and the degree of valvular calcification. In addition, the diameter of the aortic valve annulus was measured. Results were compared with surgical and echocardiographic findings by using the paired sign test, kappa statistics, and the method of Bland and Altman. RESULTS: The aortic valve could be visualized nearly free of motion artifacts on all multi-detector row CT images. Image quality and diagnostic confidence for classification of aortic valve morphology were significantly superior on contrast-enhanced rather than nonenhanced images (P = .004 and P = .006, respectively). Nonenhanced and contrast-enhanced CT showed good agreement with surgical findings with regard to quantification of the degree of aortic valve calcification (kappa = 0.77 and kappa = 0.74, respectively). Measurement of the diameter of the aortic valve annulus was more reliable on contrast-enhanced images. CONCLUSION: Contrast-enhanced retrospectively ECG-gated multi-detector row CT allows determination of aortic valve morphology, measurement of the diameter of the aortic valve annulus, and assessment of the degree of aortic valve calcification in patients with aortic stenosis. (C) RSNA, 2002.
引用
收藏
页码:120 / 128
页数:9
相关论文
共 50 条
  • [1] Three-dimensional treatment planning using electrocardiographically gated multi-detector row CT
    Yamada, K
    Soejima, T
    Minami, T
    Yoden, E
    Watanabe, Y
    Takenaka, D
    Imai, M
    Okayama, T
    Fujii, M
    Sugimura, K
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01): : 235 - 239
  • [2] Acute aortic syndromes: Role of multi-detector row CT
    Salvolini, Luca
    Renda, Pietro
    Fiore, Davide
    Scaglione, Mariano
    Piccoli, GianPiero
    Giovagnoni, Andrea
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2008, 65 (03) : 350 - 358
  • [3] Multi-detector row CT of hemoptysis
    Bruzzi, John F.
    Remy-Jardin, Martine
    Delhaye, Damien
    Teisseire, Antoine
    Khalil, Chadi
    Remy, Jacques
    [J]. RADIOGRAPHICS, 2006, 26 (01) : 3 - U78
  • [4] ECG-gated multi-detector row CT for assessment of mitral valve disease: initial experience
    Jürgen K. Willmann
    Richard Kobza
    Justus E. Roos
    Mario Lachat
    Rolf Jenni
    Paul R. Hilfiker
    Thomas F. Lüscher
    Borut Marincek
    Dominik Weishaupt
    [J]. European Radiology, 2002, 12 : 2662 - 2669
  • [5] ECG-gated multi-detector row CT for assessment of mitral valve disease:: initial experience
    Willmann, JK
    Kobza, R
    Roos, JE
    Lachat, M
    Jenni, R
    Hilfiker, PR
    Lüscher, TF
    Marincek, B
    Weishaupt, D
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (11) : 2662 - 2669
  • [6] Impact of obesity on aortic root calcification and coronary calcification using multi-detector CT
    Nafakhi, Hussein
    Al-Nafakh, Hasan A.
    Al-Mosawi, Abdulameer A.
    [J]. ARTERY RESEARCH, 2015, 9 : 27 - 32
  • [7] Impact of obesity on aortic root calcification and coronary calcification using multi-detector CT
    Hussein Nafakhi
    Hasan A. Al-Nafakh
    Abdulameer A. Al-Mosawi
    [J]. Artery Research, 2015, 9 : 27 - 32
  • [8] Retrospectively ECG-gated multidetector-row spiral CT for assessment of valvular morphology and determination of degree of calcifications in patients with aortic stenosis
    Willmann, JK
    Weishaupt, D
    Lachat, M
    Roos, J
    Marincek, B
    Hilfiker, PR
    [J]. RADIOLOGY, 2001, 221 : 413 - 414
  • [9] CT: status on multi-detector row scanners
    Martinez-Souloumiac, L.
    Gosso, F.
    [J]. JOURNAL DE RADIOLOGIE, 2006, 87 (7-8): : 927 - 935
  • [10] Clinical significance of the coronary calcification score by multi-detector row computed tomography for the evaluation of coronary stenosis
    Mitsutake, R.
    Niimura, H.
    Miura, S.
    Zhang, B.
    Iwata, A.
    Nishikawa, H.
    Kumagai, K.
    Shirai, K.
    Matsunaga, A.
    Saku, K.
    [J]. ATHEROSCLEROSIS SUPPLEMENTS, 2006, 7 (03) : 268 - 268