Coupled tuned mass dampers for control of coupled vibrations in asymmetric buildings

被引:61
|
作者
Desu, Nagendra Babu [1 ]
Deb, S. K. [1 ]
Dutta, Anjan [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Gauhati 781039, India
来源
关键词
coupled tuned mass damper; genetic algorithm; pareto optimization; passive control; asymmetric building; rigid body transformations;
D O I
10.1002/stc.64
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An arrangement of tuned mass dampers, termed coupled tuned mass dampers (CTMDs) has been introduced, where a mass is connected by translational springs and viscous dampers in an eccentric manner. The CTMD has coupled modes of lateral and rotational vibration, which have been utilized to control coupled lateral and torsional vibrations of asymmetric buildings. An efficient control strategy has been presented in this context to control displacements as well as acceleration responses of asymmetric buildings having asymmetry in both plan and elevation. The building is idealized as a simplified three-dimensional model with two translational and a rotational degrees of freedom for each floor. The principles of rigid body transformation have been incorporated to account for eccentricity between center of mass and center of rigidity. A nondominated sorting genetic algorithm (GA) has been used for solving the multi-objective optimization problem. Tuning of optimum locations of TMDs and their parameters have been done from the multiple pareto-optimal solutions obtained simultaneously. Comparative studies of performance of CTMD with conventional TMDs and bi-directional TMDs have been presented. It has been observed that CTMDs are more effective and robust in controlling coupled lateral and torsional vibrations of asymmetric buildings. The optimal locations have been observed to be reasonably compact and practically implementable for CTMDs. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:897 / 916
页数:20
相关论文
共 50 条
  • [1] Coupled Tuned Mass Dampers for the Seismic Control of Asymmetric-Plan Buildings
    Lin, Jui-Liang
    Tsai, Keh-Chyuan
    Yu, Yi-Jer
    [J]. EARTHQUAKE SPECTRA, 2010, 26 (03) : 749 - 778
  • [2] Seismic response control of asymmetric buildings using tuned mass dampers
    Taha, Ahmad Edris
    Elias, Said
    Matsagar, Vasant
    Jain, Arvind Kumar
    [J]. STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2019, 28 (18):
  • [3] Bi-directional coupled tuned mass dampers for the seismic response control of two-way asymmetric-plan buildings
    Lin, Jui-Liang
    Tsai, Keh-Chyuan
    Yu, Yi-Jer
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2011, 40 (06): : 675 - 690
  • [4] Tuned mass dampers for torsionally coupled systems
    Pansare, AP
    Jangid, RS
    [J]. WIND AND STRUCTURES, 2003, 6 (01) : 23 - 40
  • [5] DESIGN OF SERIES MULTIPLE TUNED MASS DAMPERS FOR RESPONSE CONTROL OF ASYMMETRIC BUILDINGS
    Wang, Jer-Fu
    Li, Jie-Chun
    Lin, Chi-Chang
    [J]. PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, 2017, VOL 8, 2017,
  • [6] Optimum placement and design of multiple tuned mass dampers for vibration control of asymmetric buildings
    Wang, Jer-Fu
    Lin, Ging-Long
    Lin, Chi-Chang
    Jian, Jie-Yong
    [J]. JOURNAL OF VIBRATION AND CONTROL, 2022, 28 (23-24) : 3875 - 3889
  • [7] TUNED MASS DAMPERS FOR BUILDINGS
    MCNAMARA, RJ
    [J]. JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1977, 103 (09): : 1785 - 1798
  • [8] CONTROL OF BUILDINGS USING ACTIVE - TUNED MASS DAMPERS
    CHANG, CC
    YANG, HTY
    [J]. JOURNAL OF ENGINEERING MECHANICS-ASCE, 1995, 121 (03): : 355 - 366
  • [9] Practical design issues of tuned mass dampers for torsionally coupled buildings under earthquake loadings
    Ueng, Jin-Min
    Lin, Chi-Chang
    Wang, Jer-Fu
    [J]. STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2008, 17 (01): : 133 - 165
  • [10] Tuned mass dampers for response control of torsional buildings
    Singh, MP
    Singh, S
    Moreschi, LM
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2002, 31 (04): : 749 - 769