Low-dose three-dimensional reconstruction of the femur with unit free-form deformation

被引:1
|
作者
Zeng, Xiangsen [1 ]
Wang, Chentao [1 ]
Zhou, Hai [1 ]
Wei, Shan [1 ]
Chen, Xiaojun [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, Inst Biomed Mfg & Life Qual Engn, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
low-dose x-ray image; point matching algorithm; unit free-form deformation; three-dimensional reconstruction; standard shape model; X-RAY IMAGES; STANDING POSITION; PROXIMAL FEMUR; JOINT; REGISTRATION; BONE; FIT; EOS; RADIATION; ACCURATE;
D O I
10.1118/1.4887816
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This paper describes a low-dose method for reconstructing three-dimensional models offemur, using a standard shape model (SSM) and two conventional x-ray images. Methods: The x-ray images were taken in two orthogonal directions. The x-ray source and sensor configurations were documented. An optimized algorithm was employed to align the x-ray image to the three-dimensional model. A method of direct correspondence building is proposed for linking two-dimensional images with three-dimensional projections of a SSM. The reconstruction method proposed in this paper is based on a SSM, which was adapted for x-ray images of individual bones. The adaption was executed by deforming the template bone shape until its silhouette boundary exactly matched the x-ray image of the individual bone. A silhouette-based unit free-form deformation method was evaluated for its suitability in the adaption of the SSM for x-ray images. Comprehensive experiments were designed and conducted for 35 specimens. Results: The validity of the low-dose reconstruction method was demonstrated for the femur, with good results for accuracy (mean error of 1.1 mm, root-mean-square error of 2.1 mm), reproducibility (intraobservation coefficient of variation of 1.1%, interobservation coefficient of variation of 1.4%), and time consumption (mean of 5 min for a full femur). Conclusions: Once this approach has been validated in vivo, it should be suited to multiple applications of routine clinical and research practices. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页码:361 / 371
页数:11
相关论文
共 50 条
  • [1] Three-dimensional attenuation map reconstruction using geometrical models and free-form deformations
    Battle, XL
    Le Rest, C
    Turzo, A
    Bizais, Y
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 404 - 411
  • [2] Automatic matching and three-dimensional reconstruction of free-form linear features from stereo images
    Habib, AF
    Lee, YR
    Morgan, M
    [J]. PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 2003, 69 (02): : 189 - 197
  • [3] Three-dimensional bone shape reconstruction from X-ray images using hierarchical free-form deformation and nonlinear optimization
    Gunay, M
    Shimada, K
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1291 - 1291
  • [4] Use of three-dimensional body motion to free-form surface design
    Qin, S.
    Wright, D. K.
    Kang, J.
    Prieto, P. A.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2006, 220 (02) : 335 - 339
  • [5] Tomographic reconstruction using free-form deformation models
    Battle, XL
    Bizais, YJ
    Le Rest, C
    Turzo, A
    [J]. MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 356 - 366
  • [6] Three-dimensional displacement measurement system based on optical free-form surface
    Fang, Fengzhou
    Wan, Yu
    Zhu, Pengzhe
    Cheng, Ying
    [J]. Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2014, 47 (10): : 934 - 942
  • [7] Feasibility of low-dose three-dimensional CT for peripheral bronchoscopy
    Eom, Jung Seop
    Kim, Insu
    Lee, Mim Ki
    Park, Seyeon
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [8] A Three-Dimensional Denoising Method for Low-Dose Computed Tomography
    Shang Xiaobao
    Ding Yong
    Deng Ruizhe
    Niu Tianye
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (01) : 283 - 287
  • [9] Can three-dimensional pelvimetry using low-dose stereoradiography replace low-dose CT pelvimetry?
    Aubry, S.
    Padoin, P.
    Petegnief, Y.
    Vidal, C.
    Riethmuller, D.
    Delabrousse, E.
    [J]. DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2018, 99 (09) : 569 - 576
  • [10] Development of a compression molding process for three-dimensional tailored free-form glass optics
    Yi, Allen Y.
    Huang, Chunning
    Klocke, Fritz
    Brecher, Christian
    Pongs, Guido
    Winterschladen, Markus
    Demmer, Axel
    Lange, Sven
    Bergs, Thomas
    Merz, Michael
    Niehaus, Frank