Independent absorbed-dose calculation using the Monte Carlo algorithm in volumetric modulated arc therapy

被引:9
|
作者
Haga, Akihiro [1 ]
Magome, Taiki [1 ]
Takenaka, Shigeharu [1 ]
Imae, Toshikazu [1 ]
Sakumi, Akira [1 ]
Nomoto, Akihiro [1 ]
Igaki, Hiroshi [1 ]
Shiraishi, Kenshiro [1 ]
Yamashita, Hideomi [1 ]
Ohtomo, Kuni [1 ]
Nakagawa, Keiichi [1 ]
机构
[1] Tokyo Univ Hosp, Dept Radiol, Tokyo 113, Japan
关键词
PHOTON; VERIFICATION; ENERGY; SBRT;
D O I
10.1186/1748-717X-9-75
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To report the result of independent absorbed-dose calculations based on a Monte Carlo (MC) algorithm in volumetric modulated arc therapy (VMAT) for various treatment sites. Methods and materials: All treatment plans were created by the superposition/convolution (SC) algorithm of SmartArc (Pinnacle V9.2, Philips). The beam information was converted into the format of the Monaco V3.3 (Elekta), which uses the X-ray voxel-based MC (XVMC) algorithm. The dose distribution was independently recalculated in the Monaco. The dose for the planning target volume (PTV) and the organ at risk (OAR) were analyzed via comparisons with those of the treatment plan. Before performing an independent absorbed-dose calculation, the validation was conducted via irradiation from 3 different gantry angles with a 10- x 10-cm(2) field. For the independent absorbed-dose calculation, 15 patients with cancer (prostate, 5; lung, 5; head and neck, 3; rectal, 1; and esophageal, 1) who were treated with single-arc VMAT were selected. To classify the cause of the dose difference between the Pinnacle and Monaco TPSs, their calculations were also compared with the measurement data. Result: In validation, the dose in Pinnacle agreed with that in Monaco within 1.5%. The agreement in VMAT calculations between Pinnacle and Monaco using phantoms was exceptional; at the isocenter, the difference was less than 1.5% for all the patients. For independent absorbed-dose calculations, the agreement was also extremely good. For the mean dose for the PTV in particular, the agreement was within 2.0% in all the patients; specifically, no large difference was observed for high-dose regions. Conversely, a significant difference was observed in the mean dose for the OAR. For patients with prostate cancer, the mean rectal dose calculated in Monaco was significantly smaller than that calculated in Pinnacle. Conclusions: There was no remarkable difference between the SC and XVMC calculations in the high-dose regions. The difference observed in the low-dose regions may have arisen from various causes such as the intrinsic dose deviation in the MC calculation, modeling accuracy, and CT-to-density table used in each planning system It is useful to perform independent absorbed-dose calculations with the MC algorithm in intensity-modulated radiation therapy commissioning.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Independent absorbed-dose calculation using the Monte Carlo algorithm in volumetric modulated arc therapy
    Akihiro Haga
    Taiki Magome
    Shigeharu Takenaka
    Toshikazu Imae
    Akira Sakumi
    Akihiro Nomoto
    Hiroshi Igaki
    Kenshiro Shiraishi
    Hideomi Yamashita
    Kuni Ohtomo
    Keiichi Nakagawa
    [J]. Radiation Oncology, 9
  • [2] Volumetric Modulated Arc Therapy (VMAT) Plan Validation Using MatriXX Measurements and Monte Carlo Calculation
    Kim, J.
    Fu, W.
    Pourarian, R.
    Werry, D.
    Chen, A.
    Mehta, K.
    Huq, M.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Monte Carlo Dose Verification for Volumetric Modulated Arc Therapy in Multiple Brain Metastases
    Tominaga, H.
    Araki, F.
    Kanetake, N.
    Sakata, J.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3546 - 3547
  • [4] Dosimetric impact of statistical uncertainty on Monte Carlo dose calculation algorithm in volumetric modulated arc therapy using Monaco TPS for three different clinical cases
    Palanisamy, Mohandass
    David, Khanna
    Durai, Manigandan
    Bhalla, Narendra
    Puri, Abhishek
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2019, 24 (02) : 188 - 199
  • [5] Dosimetric Impact of Statistical Uncertainty On Monte Carlo Dose Calculation in Monaco TPS Volumetric Modulated Arc Therapy for Lung Cancer
    Mohandass, P.
    Khanna, D.
    Manigandan, D.
    Kumar, M.
    Puri, A.
    Bhalla, N.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2921 - 2921
  • [6] A More Accurate Dose Calculation for Volumetric Modulated Arc Therapy
    Yang, J.
    Zhang, P.
    Hunt, M.
    Lim, S.
    LoSasso, T.
    Mageras, G.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 4020 - 4020
  • [7] Patient-Specific Quality Assurance Using Monte Carlo Dose Calculation and Elekta Log Files for Prostate Volumetric-Modulated Arc Therapy
    Katsuta, Yoshiyuki
    Kadoya, Noriyuki
    Fujita, Yukio
    Shimizu, Eiji
    Matsunaga, Kenichi
    Sawada, Kinya
    Matsushita, Haruo
    Majima, Kazuhiro
    Jingu, Keiichi
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (06) : 1220 - 1225
  • [8] Enhanced optimization of volumetric modulated arc therapy plans using Monte Carlo generated beamlets
    Mathews, Joshua
    French, Samuel B.
    Bhagroo, Stephen
    Pant, Ankit
    Nazareth, Daryl P.
    [J]. MEDICAL PHYSICS, 2020, 47 (12) : 6053 - 6067
  • [9] A Monte Carlo dose calculation algorithm for proton therapy
    Fippel, M
    Soukup, M
    [J]. MEDICAL PHYSICS, 2004, 31 (08) : 2263 - 2273
  • [10] Verification of Volumetric Modulated Arc Therapy Plans with Independent Three Dimensional Dose Computation Algorithm
    Kathirvel, M.
    Subramanian, V. Shanmuga
    Arun, G.
    Swamy, S. Thirumalai
    Ramalingam, K.
    Kala, S.
    Kumar, S. Ashok
    Anantharaman, A.
    Karthikeyan, K.
    Kumar, N. Jagdish
    Arivarasan, I.
    Babaiah, M.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)