Liquid Chromatography-Tandem Mass Spectrometry in Newborn Screening Laboratories

被引:13
|
作者
Gelb, Michael H. [1 ,2 ]
Basheeruddin, Khaja [3 ]
Burlina, Alberto [4 ]
Chen, Hsiao-Jan [5 ]
Chien, Yin-Hsiu [6 ,7 ]
Dizikes, George [8 ]
Dorley, Christine [8 ]
Giugliani, Roberto [9 ]
Hietala, Amy [10 ]
Hong, Xinying [1 ,2 ]
Kao, Shu-Min [5 ]
Khaledi, Hamid [11 ]
Klug, Tracy [12 ]
Kubaski, Francyne [9 ]
Liao, Hsuan-Chieh [13 ]
Martin, Monica [14 ]
Manning, Adrienne [15 ]
Orsini, Joseph [14 ]
Peng, Yin [3 ]
Ranieri, Enzo [16 ]
Rohrwasser, Andreas [17 ]
Szabo-Fresnais, Nicolas [17 ]
Turgeon, Coleman T. [18 ]
Vaz, Frederick M.
Wang, Li-yun
Matern, Dietrich [18 ]
机构
[1] Univ Washington, Dept Chem, Seattle, WA 98195 USA
[2] Univ Washington, Dept Biochem, Seattle, WA 98195 USA
[3] Newborn Screening Lab, Illinois Dept Publ Hlth, Chicago, IL 60612 USA
[4] Univ Hosp Padova, Reference Ctr Expanded Newborn Screening, Div Inherited Metab Dis, I-35128 Padua, Italy
[5] Chinese Fdn Hlth, Neonatal Screening Ctr, Taipei 110, Taiwan
[6] Natl Taiwan Univ Hosp, Dept Med Genet & Pediat, Taipei 100, Taiwan
[7] Natl Taiwan Univ, Coll Med, Taipei 100, Taiwan
[8] Tennessee Dept Hlth, Div Lab Serv, Knoxville, TN 37920 USA
[9] Univ Fed Rio Grande do Sul, Med Genet Serv, HCPA, DASA & Casa Raros,Dept Genet, BR-91501970 Porto Alegre, Brazil
[10] Newborn Screening Lab, Minnesota Dept Hlth, St Paul, MN 55164 USA
[11] GelbChem LLC, 4000 Mason Rd 300, Seattle, WA 98105 USA
[12] Missouri Dept Hlth & Sr Serv, POB 570, Jefferson City, MO 65102 USA
[13] Univ Washington, Dept Lab Med & Pathol, Seattle, WA 98195 USA
[14] Wadsworth Ctr, David Axelrod Inst, New York State Dept Hlth, Newborn Screening Program, 120 New Scotland Ave, Albany, NY 12201 USA
[15] Katherine A Kelley Publ Hlth Lab, Connecticut Dept Publ Hlth, Rocky Hill, CT 06067 USA
[16] SA Pathol WCH Site, Genet & Mol Pathol, Adelaide, SA 5043, Australia
[17] Utah Dept Hlth & Human Serv, Salt Lake City, UT 84129 USA
[18] Mayo Clin, Dept Lab Med & Pathol, Biochem Genet Lab, Rochester, MN 55902 USA
关键词
newborn screening; tandem mass spectrometry; liquid chromatography; dried blood spots; inborn errors of metabolism; reflex testing; DRIED BLOOD SPOTS; LYSOSOMAL STORAGE DISORDERS; CONGENITAL ADRENAL-HYPERPLASIA; FALSE-POSITIVE RATE; 2ND-TIER TEST; AMINO-ACIDS; QUANTIFICATION; DIAGNOSIS; SUCCINYLACETONE; ARYLSULFATASE;
D O I
10.3390/ijns8040062
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
Tandem mass spectrometry (MS/MS) is the most universal platform currently available for the analysis of enzymatic activities and biomarkers in dried blood spots (DBS) for applications in newborn screening (NBS). Among the MS/MS applications in NBS, the most common is flow-injection analysis (FIA-) MS/MS, where the sample is introduced as a bolus injection into the mass spectrometer without the prior fractionation of analytes. Liquid chromatography combined with MS/MS (LC-MS/MS) has been employed for second-tier tests to reduce the false-positive rate associated with several nonspecific screening markers, beginning two decades ago. More recently, LC-MS/MS has been applied to primary screening for new conditions for which FIA-MS/MS or other methods, including genomic screening, are not yet adequate. In addition to providing a list of the currently used LC-MS/MS-based assays for NBS, the authors share their experience regarding the maintenance requirements of LC-MS/MS vs. FIA-MS/MS systems. The consensus is that the maintenance of LC-MS/MS and FIA-MS/MS instrumentation is similar, and LC-MS/MS has the advantage of allowing for a larger number of diseases to be screened for in a multiplex, cost-effective fashion with a high throughput and an adequate turnaround time.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Drug screening of hair by liquid chromatography-tandem mass spectrometry
    Hegstad, S.
    Khiabani, H. Z.
    Kristoffersen, L.
    Kunoe, N.
    Lobmaier, P. P.
    Christophersen, A. S.
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2008, 32 (05) : 364 - 372
  • [2] Newborn Screening for Wilson Disease: Does Liquid Chromatography-Tandem Mass Spectrometry Provide the Solution?
    Gahl, William A.
    [J]. CLINICAL CHEMISTRY, 2008, 54 (12) : 1941 - 1942
  • [3] Liquid chromatography-tandem mass spectrometry
    Petrovic, Mira
    Barcelo, Damia
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (18) : 5857 - 5858
  • [4] ELISA screening and liquid chromatography-tandem mass spectrometry confirmation of chloramphenicol residues in chicken muscle, and the validation of a confirmatory method by liquid chromatography-tandem mass spectrometry
    Yibar, A.
    Cetinkaya, F.
    Soyutemiz, G. E.
    [J]. POULTRY SCIENCE, 2011, 90 (11) : 2619 - 2626
  • [5] Endogenous glucocorticoid analysis by liquid chromatography-tandem mass spectrometry in routine clinical laboratories
    Hawley, James M.
    Keevil, Brian G.
    [J]. JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2016, 162 : 27 - 40
  • [6] Newborn screening for congenital adrenal hyperplasia: Additional steroid profile using liquid chromatography-tandem mass spectrometry
    Janzen, N.
    Peter, M.
    Sander, S.
    Steuerwald, U.
    Terhardt, M.
    Holtkamp, U.
    Sander, J.
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2007, 92 (07): : 2581 - 2589
  • [7] Development of Second-Tier Liquid Chromatography-Tandem Mass Spectrometry Analysis for Expanded Newborn Screening in Japan
    Shigematsu, Yosuke
    Yuasa, Miori
    Ishige, Nobuyuki
    Nakajima, Hideki
    Tajima, Go
    [J]. INTERNATIONAL JOURNAL OF NEONATAL SCREENING, 2021, 7 (03)
  • [8] The use of liquid chromatography-tandem mass spectrometry in newborn screening for congenital adrenal hyperplasia: improvements and future perspectives
    de Hora, Mark
    Heather, Natasha
    Webster, Dianne
    Albert, Benjamin
    Hofman, Paul
    [J]. FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [9] Screening of anabolic steroids in horse urine by liquid chromatography-tandem mass spectrometry
    Yu, NH
    Ho, ENM
    Leung, DKK
    Wan, TSM
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (05) : 1031 - 1038
  • [10] Screening for X-linked adrenoleukodystrophy by liquid chromatography-tandem mass spectrometry
    Tortorelli, S.
    Hubbard, W. C.
    Moser, A. B.
    Liu, A.
    Jones, D.
    Moser, H.
    [J]. JOURNAL OF INHERITED METABOLIC DISEASE, 2006, 29 : 54 - 54