Practical experiences with granular activated carbon (GAC) at the Rietvlei Water Treatment Plant

被引:0
|
作者
Clements, M [1 ]
Haarhoff, J [1 ]
机构
[1] Rand Afrikaans Univ, Water Res Grp, ZA-2006 Auckland Pk, South Africa
关键词
granular activated carbon; regeneration; bed expansion; backwashing; abrasion; apparent density;
D O I
暂无
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
The Rietvlei Water Treatment Plant was extended with a granular activated carbon (GAC) filtration system after an exhaustive, series of test, which were started in 1994. Upon commissioning towards the middle of 1999, a year of close monitoring followed to measure the GAC performance at full-scale. After verification that the GAC does indeed ensure a high quality product under all conditions, the emphasis shifted to the optimisation of the GAC handling and regeneration system. Frequently moving the entire GAC inventory from the filters to an off-site regeneration plant and back requires significant operational effort and contributes a major part of the total cost of the GAC system. A number of systematic investigations were carried out in response to a number of practical questions that arose at Rietvlei. The first part of the study was directed towards tracking and quantifying the GAC on- and off-site. The main findings were that 10.0% of the GAC is lost from the filter during back washing (0.3%) and removal of GAC from the filter for regeneration (9.7%). The sump does not trap all this GAC and 2.3% of the total inventory is lost to the river. Inserting a sieve at the outlet of the sump can eliminate this loss. A further 80.3% of the GAC in a filter is removed for regeneration, of which 18.7% is lost during the regeneration process. The minimising of this loss can only be achieved through the optimisation of the regeneration process, which falls within the domain of the regeneration contractor. The second part of the study was directed at the behaviour of the GAC whilst within the filter bed. The porosity and sphericity were determined by laboratory tests and calculations. The porosity was found to be 0.69 for the 12 x 40 size carbon and 0.66 for the 8 x 30 size carbon. By using a calibrated bed expansion model, bed expansion could be calculated at 9degreesC and 23degreesC for the two carbon gratings; the maximum temperature range experienced at Rietvlei. The main finding of this part of the study was that the average available freeboard is 650 mm for the 12 x 40 grading and 430 mm for the 8 x 30 grading, and therefore no GAC should wash over the weir at all during backwashing. The third part of the study measured the physical changes of the GAC found at different points in the GAC cycle. The main findings were that the small fraction of GAC washed out of the bed during backwashing and removal has a finer grading, higher apparent density and lower adsorption capacity than the GAC in the filter bed. There seems to be no marked attrition of the carbon or generation of fines during the removal and transport of the GAC to the regeneration plant. After regeneration, there was a 7.0% decrease in apparent density and a 30.0% increase in adsorption capacity. The final part of the study correlated the adsorption capacity of the GAC with its time in use as well as UV254 removal. After regeneration, UV254 removal begins at approximately 20.0% and declines to 14.0% after 400 d of operation, and to 10.0% after 600 d. After regeneration, the iodine number begins at approximately 800 g/mg declines to 600 g/mg after 400 d of operation, and to 500 g/mg after 600 d.
引用
收藏
页码:89 / 95
页数:7
相关论文
共 50 条
  • [1] Study on deterioration of water treatment capability of granular activated carbon (GAC) in Osaka City
    Ando, A.
    Kajiyama, Y.
    Takigawa, N.
    [J]. Drinking Water Treatment, Supply and Management in Asia (IWA-ASPIRE 2005), 2006, 6 (02): : 245 - 251
  • [2] Fate of Trace Organic Compounds in Granular Activated Carbon (GAC) Adsorbers for Drinking Water Treatment
    Sperlich, Alexander
    Harder, Mareike
    Zietzschmann, Frederik
    Gnirss, Regina
    [J]. WATER, 2017, 9 (07):
  • [3] COMBINED USE OF OZONE AND GRANULAR ACTIVATED CARBON (GAC) IN POTABLE WATER-TREATMENT - EFFECTS ON GAC QUALITY AFTER REACTIVATION
    BOERE, JA
    [J]. OZONE-SCIENCE & ENGINEERING, 1992, 14 (02) : 123 - 137
  • [4] GRANULAR ACTIVATED CARBON IN WATER TREATMENT
    MCCREARY, JJ
    SNOEYINK, VL
    [J]. JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1977, 69 (08): : 437 - 444
  • [5] Application of a method to quantify carbonate precipitated on granular activated carbon (GAC) used in potable water treatment
    McCafferty, ND
    Callow, ME
    Hoggett, L
    Holden, B
    Leadbeater, BSC
    [J]. WATER RESEARCH, 2000, 34 (08) : 2199 - 2206
  • [6] Advanced water treatment process by simultaneous coupling granular activated carbon (GAC) and powdered carbon with ultrafiltration: Role of GAC particle shape and powdered carbon type
    Zhang, Jingyu
    Yu, Sijia
    Wang, Jingwei
    Zhao, Zhi-Ping
    Cai, Weiwei
    [J]. WATER RESEARCH, 2023, 231
  • [7] Granular activated carbon (GAC) adsorption in tertiary wastewater treatment: experiments and models
    Chaudhary, DS
    Vigneswaran, S
    Jegatheesan, V
    Ngo, HH
    Moon, H
    Shim, WG
    Kim, SH
    [J]. WATER SCIENCE AND TECHNOLOGY, 2003, 47 (01) : 113 - 120
  • [8] THE INFLUENCE OF GRANULAR ACTIVATED CARBON (GAC) TREATED BY DBD
    Zhang, Yue
    Li, Jie
    Li, Guofeng
    Qu, Guangzhou
    Wu, Yan
    [J]. PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON APPLIED ELECTROSTATICS, 2008, : 120 - 122
  • [9] Bacteriological Changes Associated with Granular Activated Carbon in a Pilot Water Treatment Plant
    Helmy Tawfik El-Zanfaly
    Donald J. Reasoner
    Edwin E. Geldreich
    [J]. Water, Air, and Soil Pollution, 1998, 107 : 73 - 80
  • [10] Bacteriological changes associated with granular activated carbon in a pilot water treatment plant
    El-Zanfaly, HT
    Reasoner, DJ
    Geldreich, EE
    [J]. WATER AIR AND SOIL POLLUTION, 1998, 107 (1-4): : 73 - 80