Exploring Flow Cytometry-Based Micronucleus Scoring for Reliable Nanomaterial Genotoxicity Assessment

被引:14
|
作者
Franz, Pauline [1 ]
Buerkle, Alexander [2 ]
Wick, Peter [1 ]
Hirsch, Cordula [1 ]
机构
[1] Empa Swiss Fed Labs Mat Sci & Technol, Lab Particles Biol Interact, CH-9014 St Gallen, Switzerland
[2] Univ Konstanz, Dept Biol, Chair Mol Toxicol, D-78457 Constance, Germany
关键词
TITANIUM-DIOXIDE PARTICLES; IN-VITRO; COMET ASSAY; DNA-DAMAGE; SILICA NANOPARTICLES; CELLS; INTERFERENCE; VIVO;
D O I
10.1021/acs.chemrestox.0c00071
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The increased use of engineered nanomaterials (ENM) such as SiO2 and TiO2 in industrial products, especially in food, raises concerns with regard to their effect on human health. In particular, ENM-induced genotoxicity is crucial to investigate, since DNA damage can cause induction or promotion of carcinogenesis. However, current in vitro and in vivo nanogenotoxicological data are highly contradictory, which impedes interpretation and extrapolation. Hence, robust, reliable, and ideally scalable in vitro methods for nanogenotoxicity assessment are of great interest. This work aimed at evaluating the suitability of flow cytometry-based micronuclei scoring for reliable nanogenotoxicological assessment in human intestinal cells. Therefore, we have evaluated the genotoxicity of differently sized SiO2 and TiO2 from different sources (food-relevant, commercially available, and laboratory-synthesized) using the well-established alkaline single cell gel electrophoresis (Comet assay) and the micronucleus (MN) assay employing a flow cytometric readout. Our study demonstrates that physiologically relevant doses of several types of SiO2 and TiO2 did not cause genotoxicity, as assessed by the Comet assay, and the MN flow cytometry assay under the particular experimental conditions described. To improve data reliability, we identified ENM-induced interferences with flow cytometric scoring employing a set of interference controls, which is generally applicable for any nanomaterial and any cell line. In conclusion, flow cytometry-based MN scoring appears to be a promising methodology in nanogenotoxicity testing since data acquisition and analysis are significantly faster, highly scalable in terms of throughput, and less operator-dependent compared to the traditional microscopic evaluation. In particular, ENM-induced falsepositive or false-negative results, which have not been addressed sufficiently in the literature, can be detected easily, thus enhancing data reliability.
引用
收藏
页码:2538 / 2549
页数:12
相关论文
共 50 条
  • [1] Dramatically Increasing the Capacity of Genotoxicity Testing: Automating a Flow Cytometry-Based In Vitro Micronucleus Assay
    Liu, Z.
    Bryce, S.
    Bemis, J.
    Luu, Y. K.
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2012, 53 : S48 - S48
  • [2] Validation of the Flow Cytometry-Based In Vitro Micronucleus Assay
    Zhou, C.
    Ou, H.
    Tu, H.
    Xu, L.
    Chang, Y.
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2015, 56 : S73 - S73
  • [3] Semicarbazide is not genotoxic in the flow cytometry-based micronucleus assay in vivo
    Abramsson-Zetterberg, L
    Svensson, K
    TOXICOLOGY LETTERS, 2005, 155 (02) : 211 - 217
  • [4] Evaluating the genotoxicity of tobacco smoke-derived aerosols using the flow cytometry-based in vitro micronucleus assay
    Pouleau, Blandine
    Smart, Daniel
    McHugh, Damian
    MUTAGENESIS, 2014, 29 (06) : 511 - 511
  • [5] A comparison Of Two Cell Lines For Testing The Genotoxicity Using A Flow Cytometry-Based In Vitro Micronucleus Assay.
    Alqudaihi, Ghofran
    Subramanian, S.
    Alsaleh, I
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2017, 58 : S54 - S55
  • [6] Performance of the flow cytometry-based in vitro micronucleus assay in a validation study
    Smart, D. J.
    Helbling, F.
    Blandine, P.
    Damian, M.
    Patrick, V.
    TOXICOLOGY LETTERS, 2016, 258 : S316 - S316
  • [7] Use of Human TK6 Lymphoblastoid and HepaRG Cell Lines for Genotoxicity Testing in a Flow Cytometry-Based In Vitro Micronucleus Assay
    Swartz, C. D.
    Recio, L.
    Green, A.
    Buick, J.
    Yauk, C. L.
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2014, 55 : S44 - S44
  • [8] Flow cytometry-based in vitro micronucleus scoring: 384-well plate format provides for higher throughput and low compound requirements
    Bryce, S.
    Avlasevich, S.
    Dertinger, S.
    TOXICOLOGY LETTERS, 2011, 205 : S103 - S103
  • [9] Low dose genotxicity assessment of acrylamide using biomarkers of internal dose and flow cytometry-based micronucleus assay in mice
    Zeiger, Errol
    Friedman, Marvin
    Recio, Les
    Fennell, Tim
    Haseman, Joe
    TOXICOLOGY LETTERS, 2009, 189 : S246 - S246
  • [10] Development of a novel flow cytometry-based approach for reticulocytes micronucleus test in rat peripheral blood
    Chen, Yiyi
    Huo, Jiao
    Liu, Yunjie
    Zeng, Zhu
    Zhu, Xuejiao
    Chen, Xuxi
    Wu, Rui
    Zhang, Lishi
    Chen, Jinyao
    JOURNAL OF APPLIED TOXICOLOGY, 2021, 41 (04) : 595 - 606