Time-Optimal Design for Multidimensional and Parallel Transmit Variable-Rate Selective Excitation

被引:30
|
作者
Lee, Daeho [1 ]
Lustig, Michael [1 ]
Grissom, William A. [1 ]
Pauly, John M. [1 ]
机构
[1] Stanford Univ, Dept Elect Engn, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USA
关键词
RF excitation; VERSE; time-optimal; multidimensional; parallel; SAR; RF PULSE DESIGN; GRADIENT WAVE-FORMS; SPIN-ECHO; OPTIMIZATION; ALGORITHM;
D O I
10.1002/mrm.21950
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Variable-rate selective excitation (VERSE) is a radio frequency (RF) pulse reshaping technique. It is most commonly used to reduce the peak magnitude and specific absorption rate (SAR) of RF pulses by reshaping pulses and gradient waveforms to reduce RF magnitude while preserving excitation profiles. In this work, a general time-optimal VERSE algorithm for multidimensional and parallel transmit pulses is presented. Time optimality is achieved by translating peak RF limits to gradient upper bounds in excitation k-space. The limits are fed into a time-optimal gradient waveform design technique. Effective SAR reduction is achieved by reducing peak RF subject to a fixed pulse length. The presented method is different from other VERSE techniques in that it provides a noniterative time-optimal multidimensional solution, which drastically simplifies VERSE designs. Examples are given for 1D and 2D single channel and 2D parallel transmit pulses. Magn Reson Med 61:1471-1479, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:1471 / 1479
页数:9
相关论文
共 50 条
  • [1] VARIABLE-RATE SELECTIVE EXCITATION
    CONOLLY, S
    NISHIMURA, D
    MACOVSKI, A
    GLOVER, G
    JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03): : 440 - 458
  • [2] Variable-rate selective excitation for rapid MRI sequences
    Hargreaves, BA
    Cunningham, CH
    Nishimura, DG
    Conolly, SM
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) : 590 - 597
  • [3] On the design of variable-rate optimal convolutional encoders for turbo codes
    Amat, AGI
    Benedetto, S
    Montorsi, G
    GLOBECOM'03: IEEE GLOBAL TELECOMMUNICATIONS CONFERENCE, VOLS 1-7, 2003, : 2056 - 2061
  • [4] Application of Variable-Rate Selective Excitation Pulses for Spin Labeling in Perfusion MRI
    He, Jiabao
    Blamire, Andrew M.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) : 842 - 847
  • [5] Time-optimal multidimensional gradient waveform design for rapid imaging
    Hargreaves, BA
    Nishimura, DG
    Conolly, SM
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) : 81 - 92
  • [6] A variable-rate modulation scheme for transmit diversity in wireless multimedia communications
    Fan, PY
    Cao, ZG
    Feng, CX
    2002 IEEE REGION 10 CONFERENCE ON COMPUTERS, COMMUNICATIONS, CONTROL AND POWER ENGINEERING, VOLS I-III, PROCEEDINGS, 2002, : 948 - 951
  • [7] Lower bound of transition time in multidimensional time-optimal problems
    Ignatov, IM
    Kurkin, OM
    AUTOMATION AND REMOTE CONTROL, 1996, 57 (11) : 1544 - 1547
  • [8] Evaluating of the Quality of Hepatic Diffusion Weighted Imaging Using Multiband Imaging With Variable-Rate Selective Excitation
    Yoshida, Naofumi
    Nakaura, Takeshi
    Morita, Kosuke
    Yoneyama, Masami
    Inoue, Taihei
    Tanoue, Shota
    Uetani, Hiroyuki
    Oda, Seitaro
    Nagayama, Yasunori
    Kidoh, Masafumi
    Hirai, Toshinori
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (05) : 693 - 700
  • [9] Time-Optimal Control of a Multidimensional Integrator Chain With Applications
    Leomanni, Mirko
    Costante, Gabriele
    Ferrante, Francesco
    IEEE CONTROL SYSTEMS LETTERS, 2022, 6 : 2371 - 2376
  • [10] Design Considerations for Variable-Rate Digital Signal Processing
    Chen, Yu
    Tsividis, Yannis
    2016 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2016, : 2479 - 2482