Detection and quantification of plasma amyloid-β by selected reaction monitoring mass spectrometry

被引:30
|
作者
Kim, Jun Seok [1 ]
Ahn, Hee-Sung [1 ,2 ]
Cho, Soo Min [3 ]
Lee, Ji Eun [1 ]
Kim, YoungSoo [3 ]
Lee, Cheolju [1 ,2 ]
机构
[1] Korea Inst Sci & Technol, Ctr Theragnosis, Seoul 136791, South Korea
[2] Univ Sci & Technol, Dept Biol Chem, Taejon 305333, South Korea
[3] Korea Inst Sci & Technol, Ctr Neuromed, Seoul 136791, South Korea
关键词
Alzheimer's disease; Amyloid-beta; Selected reaction monitoring; High pH reversed-phase liquid chromatography; Surrogate peptide; Plasma; ALZHEIMERS-DISEASE PATIENTS; CEREBROSPINAL-FLUID; PEPTIDES; PROTEIN; QUANTITATION; CHROMATOGRAPHY; IDENTIFICATION; BIOMARKERS; A-BETA-42; ASSAYS;
D O I
10.1016/j.aca.2014.06.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Amyloid-beta (A beta) in human plasma was detected and quantified by an antibody-free method, selected reaction monitoring mass spectrometry (SRM-MS) in the current study. Due to its low abundance, SRM-based quantification in 10 mu L plasma was a challenge. Prior to SRM analysis, human plasma proteins as a whole were digested by trypsin and high pH reversed-phase liquid chromatography (RPLC) was used to fractionate the tryptic digests and to collect peptides, A beta(1-5), A beta(6-16), A beta(17-28) and A beta(29-40(42)) of either A beta(1-40) or A beta(1-42). Among those peptides, A beta(17-28) was selected as a surrogate to measure the total A beta level. Human plasma samples obtained from triplicate sample preparations were analyzed, obtaining 4.20 ng mL(-1) with a CV of 25.3%. Triplicate measurements for each sample preparation showed CV of <5%. Limit of quantification was obtained as 132 pM, which corresponded to 570 pg mL(-1) of A beta(1-40). Until now, most quantitative measurements of A beta in plasma or cerebrospinal fluid have required antibody-based immunoassays. Since quantification of A beta by immunoassays is highly dependent on the extent of epitope exposure due to aggregation or plasma protein binding, it is difficult to accurately measure the actual concentration of A beta in plasma. Our diagnostic method based on SRM using a surrogate peptide of A beta is promising in that actual amounts of total A beta can be measured regardless of the conformational status of the biomarker. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [1] Selected Reaction Monitoring Mass Spectrometry for Absolute Protein Quantification
    Manes, Nathan P.
    Mann, Jessica M.
    Nita-Lazar, Aleksandra
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2015, (102): : 1 - 15
  • [2] Mass spectrometry–based detection and quantification of plasma glycoproteins using selective reaction monitoring
    Yeoun Jin Kim
    Zaya Zaidi-Ainouch
    Sebastien Gallien
    Bruno Domon
    Nature Protocols, 2012, 7 : 859 - 871
  • [3] Mass-Spectrometry Quantification of Protein Biomarkers by Selected Reaction Monitoring
    Faktor, Jakub
    Struharova, Iva
    Fucikova, Alena
    Hubalek, Marten
    Vojtesek, Borivoj
    Bouchal, Pavel
    CHEMICKE LISTY, 2011, 105 (11): : 846 - 850
  • [4] Mass spectrometry-based detection and quantification of plasma glycoproteins using selective reaction monitoring
    Kim, Yeoun Jin
    Zaidi-Ainouch, Zaya
    Gallien, Sebastien
    Domon, Bruno
    NATURE PROTOCOLS, 2012, 7 (05) : 859 - 871
  • [5] A rapid and sensitive method for the quantification of ganciclovirin plasma using liquid chromatography/selected reaction monitoring/mass spectrometry
    Xu, KY
    Lanuti, M
    Lambright, ES
    Force, SD
    Albelda, SM
    Blair, IA
    BIOMEDICAL CHROMATOGRAPHY, 2000, 14 (02) : 93 - 98
  • [6] Validated B vitamin quantification from lentils by selected reaction monitoring mass spectrometry
    Zhang, Haixia
    De Silva, Devini
    Dissanayaka, Dilanganie
    Warkentin, Thomas D.
    Vandenberg, Albert
    FOOD CHEMISTRY, 2021, 359
  • [7] A selective and rapid method for the quantification of captopril in human plasma using liquid chromatography/selected reaction monitoring mass spectrometry
    Salem, II
    Abu Saif, W
    Jmeian, Y
    Al Tamimi, JI
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (05) : 1073 - 1080
  • [8] Quantification of Milk Fat Globule Membrane Proteins Using Selected Reaction Monitoring Mass Spectrometry
    Fong, Bertram Y.
    Norris, Carmen S.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (14) : 6021 - 6028
  • [9] Detection and quantification of EGF receptor phosphorylation in formalin-fixed tumor sections by selected/multiple reaction monitoring mass spectrometry
    Taylor, P.
    Tong, J.
    Shih, W.
    Darfler, M. M.
    Tsao, M. S.
    Krizman, D. B.
    Eitner, C.
    Moran, M. F.
    EJC SUPPLEMENTS, 2009, 7 (04): : 31 - 31
  • [10] Protein Quantification by MALDI-Selected Reaction Monitoring Mass Spectrometry Using Sulfonate Derivatized Peptides
    Lesur, Antoine
    Varesio, Emmanuel
    Hopfgartner, Gerard
    ANALYTICAL CHEMISTRY, 2010, 82 (12) : 5227 - 5237