With high spatial resolution of ultrasonic location and high sensitivity of optical detection, ultrasound-modulated optical tomography (UOT) is a promising noninvasive biological tissue imaging technology. In biological tissue, the ultrasound-modulated light signals are very weak and are overwhelmed by the strong unmodulated light signals. It is a difficulty and key to efficiently pick out the weak modulated light from strong unmodulated light in UOT. Under the effect of an ultrasonic field, the scattering light intensity presents a periodic variation as the ultrasonic frequency changes. So the modulated light signals would be escape from the high unmodulated light signals, when the modulated light signals and the ultrasonic signal are processed cross correlation operation by a lock-in amplifier and without a chopper. Experimental results indicated that the signal-to-noise ratio of UOT is significantly improved by a lock-in amplifier, and the higher the repetition frequency of pulsed ultrasonic wave, the better the signal-to-noise ratio of UOT.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Signal dependence and noise source in ultrasound-modulated optical tomography
    Yao, G
    Wang, LHV
    [J]. APPLIED OPTICS, 2004, 43 (06) : 1320 - 1326
  • [2] Signal and noise in ultrasound-modulated optical tomography: a Monte Carlo Study
    Yao, G
    Wang, LHV
    [J]. PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING, 2004, 5320 : 156 - 163
  • [3] PRECISION OF LOCK-IN AMPLIFIERS AS A FUNCTION OF SIGNAL-TO-NOISE RATIO
    GUALTIERI, DM
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (02): : 299 - 300
  • [4] Lock-in camera based heterodyne holography for ultrasound-modulated optical tomography inside dynamic scattering media
    Liu, Yan
    Shen, Yuecheng
    Ma, Cheng
    Shi, Junhui
    Wang, Lihong V.
    [J]. APPLIED PHYSICS LETTERS, 2016, 108 (23)
  • [5] Analysis on frequency response of trans-impedance amplifier (TIA) for signal-to-noise ratio (SNR) enhancement in optical signal detection system using lock-in amplifier (LIA)
    Kim, Ji-Hoon
    Jeon, Su-Jin
    Ji, Myung-Gi
    Park, Jun-Hee
    Choi, Young-Wan
    [J]. SMART PHOTONIC AND OPTOELECTRONIC INTEGRATED CIRCUITS XIX, 2017, 10107
  • [6] Structured ultrasound-modulated optical tomography
    Bocoum, Maimouna
    Gennisson, Jean-Luc
    Laudereau, Jean-Baptiste
    Louchet-Chauvet, Anne
    Tualle, Jean-Michel
    Ramaz, Francois
    [J]. APPLIED OPTICS, 2019, 58 (08) : 1933 - 1940
  • [7] Chirped ultrasound-modulated optical tomography
    Ku, G
    Yao, G
    Wang, LHV
    [J]. OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE III, PROCEEDINGS OF, 1999, 3597 : 371 - 375
  • [8] Pulsed ultrasound modulated optical tomography with harmonic lock-in holography detection
    Ruan, Haowen
    Mather, Melissa L.
    Morgan, Stephen P.
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2013, 30 (07) : 1409 - 1416
  • [9] Optical phantoms for ultrasound-modulated optical tomography
    Kim, Chulhong
    Garcia-Uribe, Alejandro
    Kothapalli, Sri-Rajasekhar
    Wang, Lihong V.
    [J]. DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENTS OF TISSUE, 2008, 6870
  • [10] Optical signal-to-noise ratio measurement by optical homodyne tomography
    Martelli, P
    Pietralunga, SM
    Ranzani, L
    Siano, R
    Martinelli, M
    [J]. OPTICS LETTERS, 2006, 31 (03) : 302 - 304