Real-Time Electrochemical Monitoring of the Polymerase Chain Reaction by Mediated Redox Catalysis

被引:48
|
作者
Defever, Thibaut [1 ]
Druet, Michel [1 ]
Rochelet-Dequaire, Murielle [2 ]
Joannes, Martine [3 ]
Grossiord, Celine [3 ]
Limoges, Benoit [1 ]
Marchal, Damien [1 ]
机构
[1] Univ Paris Diderot, CNRS, Electrochim Mol Lab, UMR 7591, F-75205 Paris 13, France
[2] Univ Bourgogne, Fac Med & Pharm, Lab Interact Muqueuses Agents Transmissibles, EA 562, F-21000 Dijon, France
[3] Argene SA, Parc Technol Delta Sud, F-09340 Verniolle, France
关键词
DNA AMPLIFICATION; ACHROMOBACTER-XYLOSOXIDANS; ELECTRON-TRANSFER; MOLECULAR BEACONS; PCR-AMPLIFICATION; HYBRIDIZATION; FLUORESCENCE; PRODUCT; OLIGONUCLEOTIDES; QUANTIFICATION;
D O I
10.1021/ja901368m
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We described the proof-of-principle of a nonoptical real-time PCR that uses cyclic voltammetry for indirectly monitoring the amplified DNA product generated in the PCR reaction solution after each PCR cycle. To enable indirect measurement of the amplicon produced throughout PCR, we monitor electrochemically the progressive consumption (i.e., the decrease of concentration) of free electroactive deoxynucleoside triphosphates (dNTPs) used for DNA synthesis. This is accomplished by exploiting the fast catalytic oxidation of native deoxyguanosine triphosphate (dGTP) or its unnatural analogue 7-deaza-dGTP by the one-electron redox catalysts Ru(bpy)(3)(3+) (with bpy = 2,2'-bipyridine) or Os(bpy)(3)(3+) generated at an electrode. To demonstrate the feasibility of the method, a disposable array of eight miniaturized self-contained electrochemical cells (working volume of 50 mu L) has been developed and implemented in a classical programmable thermal cycler and then tested with the PCR amplification of two illustrated examples of real-world biological target DNA sequences (i.e., a relatively long 2300-bp sequence from the bacterial genome of multidrug-resistant Achromobacter xylosoxidans and a shorter 283-bp target from the human cytomegalovirus). Although the method works with both mediator/base couples, the catalytic peak current responses recorded with the Ru(bpy)(3)(3+)/dGTP couple under real-time PCR conditions are significantly affected by a continuous current drift and interference with the background solvent discharge, thus leading to poorly reproducible data. Much more reproducible and reliable results are finally obtained with the Os(bPY)(3)(3+)/7-deaza-dGTP, a result that is attributed to the much lower anodic potential at which the catalytic oxidation of 7-deaza-dGTP by Os(bPY)(3)(3+) is detected. Under these conditions, an exponential decrease of the catalytic signal as a function of the number of PCR cycles is obtained, allowing definition of a cycle threshold value (C-t) that correlates inversely with the initial amount of target DNA. A semilogarithmic plot of C-t with the initial copy number of target DNA gives a standard linear curve similar to that obtained with fluorescent-based real-time PCR. Although the detection limit (10(3) molecules of target DNA in 50 mu L) and sensitivity of the electrochemical method is not as high as conventional optical-based real-time PCR, the methodology described here offers many of the advantages of real-time PCR, such as a high dynamic range (over 8-log(10)) and speed, high amplification efficiency (close to 2), and the elimination of post-PCR processing. The method also has the advantage of being very simple, just requiring the use of low-cost single-use electrodes and the addition of a minute amount of redox catalyst into the PCR mixture. Moreover, compared to the other recently developed electrochemical real-time PCR based on solid-phase amplification, the present approach does not require electrode functionalization by a DNA probe. Finally, on account of the relative insensitivity of electrochemical methods to downscaling, the detection scheme is quite promising for, use in miniaturized devices and in the development of point-of-care diagnosis applications.
引用
收藏
页码:11433 / 11441
页数:9
相关论文
共 50 条
  • [1] Electrochemical real-time polymerase chain reaction
    Yeung, Stephen S. W.
    Lee, Thomas M. H.
    Hsing, I.-Ming
    Journal of the American Chemical Society, 2006, 128 (41): : 13374 - 13375
  • [2] Electrochemical real-time polymerase chain reaction
    Yeung, Stephen S. W.
    Lee, Thomas M. H.
    Hsing, I-Ming
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (41) : 13374 - 13375
  • [3] Real-time polymerase chain reaction
    Oldach, D
    GASTROENTEROLOGY, 1999, 116 (03) : 763 - 765
  • [4] Real-time polymerase chain reaction
    Wilhelm, J
    Pingoud, A
    CHEMBIOCHEM, 2003, 4 (11) : 1120 - 1128
  • [5] Real-time monitoring of small biological molecules by ligation-mediated polymerase chain reaction
    Zhang, Yan
    Liu, Jiao
    Zhang, Chun-yang
    CHEMICAL COMMUNICATIONS, 2015, 51 (61) : 12270 - 12273
  • [6] Detection of a few DNA copies by real-time electrochemical polymerase chain reaction
    Moreau, M.
    Delile, S.
    Sharma, A.
    Fave, C.
    Perrier, A.
    Limoges, B.
    Marchal, D.
    ANALYST, 2017, 142 (18) : 3432 - 3440
  • [7] Real-time polymerase chain reaction with electrochemical detection for detection pandemic viruses
    Adam, V.
    Huska, D.
    Krizkova, S.
    Hubalek, J.
    Kizek, R.
    FEBS JOURNAL, 2009, 276 : 95 - 96
  • [8] Simulation and real-time monitoring of polymerase chain reaction for its higher efficiency
    Lee, JY
    Lim, HW
    Yoo, SI
    Zhang, BT
    Park, TH
    BIOCHEMICAL ENGINEERING JOURNAL, 2006, 29 (1-2) : 109 - 118
  • [9] Minimization of Real-Time Polymerase Chain Reaction System
    Hwang, Ji Soo
    Kim, Yeo-Reum
    Park, Chan Young
    Song, Hye Jeong
    Kim, Yu Seop
    Kim, Jong Dae
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 124 : 7 - 7
  • [10] Real-Time Polymerase Chain Reaction A Revolution in Diagnostics
    Pabla, Simarjot Singh
    Pahla, Sarabjot Singh
    RESONANCE-JOURNAL OF SCIENCE EDUCATION, 2008, 13 (04): : 369 - 377