Clinical therapeutic effects of AO/ASIF clavicle hook plate on distal clavicle fractures and acromioclavicular joint dislocations

被引:3
|
作者
Dou, Qingjun [1 ,2 ]
Ren, Xiaofeng [1 ,2 ]
机构
[1] Liaocheng Peoples Hosp, Dept Orthoped, Liaocheng 252000, Peoples R China
[2] Taishan Med Univ, Liaocheng Clin Sch, Liaocheng 252000, Peoples R China
关键词
AO/ASIF claviclehook plate; Distal clavicle fracture; Acromioclavicular joint dislocation; Therapeutic effect; KIRSCHNER WIRES; FIXATION; SHOULDER;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aim of this study was to evaluate the security and effectiveness of AO/ASIF clavicle hook plate in the treatment of distal clavicle fractures and acromioclavicular joint dislocations. Methods: One hundred patients with distal clavicle fractures and acromioclavicular joint dislocations who were admitted in our hospital from January 2012 to January 2013 were selected as the study subjects. They were then randomly divided into a control group and an observation group (n=50). The observation group was treated with AO/ASIF clavicle hook plates, and the control group was treated with Kirschnerwire tension bands. The outcomes were recorded and compared. Results: The JOA scores of the two groups were similar before surgery (P > 0.05). The two groups both had obviously increased JOA scores in the postoperative 6th and 12th weeks, and the score in the postoperative 12th week was higher. There were statistically significant intra-group differences (P < 0.05). The postoperative 6th-week and 12th-week JOA scores of the observation group were (83.2 +/- 1.8) and (97.4 +/- 1.5) respectively, and those of the control group were (71.6 +/- 2.2) and (82.3 +/- 2.6) respectively, with statistically significant inter-group differences (P < 0.05). Significantly more patients in the observation group (100%) were evaluated as excellent or good outcomes after fixation than those in the control group (60%). After removal of the surgical apparatus, the recurrence rates of bone fracture and joint dislocation in the observation group were significantly lower than those of the control group (P < 0.05). Conclusion: AO/ASIF clavicle hook plate functioned more effectively than Kirschner-wire tension band in clinical treatment of distal clavicle fractures and acromioclavicular joint dislocations. The former protocol enjoyed small incisions, firm fixation and early shoulder mobility. Therefore, it is a safe and effective surgical method that is worthy of being widely applied in clinical practice.
引用
收藏
页码:868 / 871
页数:4
相关论文
共 50 条
  • [1] The Results of Hook Plate Fixation in Acute Acromioclavicular Joint Dislocation and Distal Clavicle Fractures
    Shaty, Wahby
    ORTHOPEDIC REVIEWS, 2024, 16
  • [2] Clavicle hook plate versus distal clavicle locking plate for Neer type II distal clavicle fractures
    Li, Liang
    Li, Tian-yan
    Jiang, Peichao
    Lin, Guizhen
    Wu, Hongxiao
    Han, Xiaochuan
    Yu, Xuezhong
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (01)
  • [3] Clavicle hook plate versus distal clavicle locking plate for Neer type II distal clavicle fractures
    Liang Li
    Tian-yan Li
    Peichao Jiang
    Guizhen Lin
    Hongxiao Wu
    Xiaochuan Han
    Xuezhong Yu
    Journal of Orthopaedic Surgery and Research, 14
  • [4] Use of the AO hook-plate for treatment of unstable fractures of the distal clavicle
    Muramatsu, K.
    Shigetomi, M.
    Matsunaga, T.
    Murata, Y.
    Taguchi, T.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (03) : 191 - 194
  • [5] Use of the AO hook-plate for treatment of unstable fractures of the distal clavicle
    K. Muramatsu
    M. Shigetomi
    T. Matsunaga
    Y. Murata
    T. Taguchi
    Archives of Orthopaedic and Trauma Surgery, 2007, 127 : 191 - 194
  • [6] Treatment of displaced lateral clavicle fractures with the AO hook plate
    Bhangal K.K.
    Evans S.C.
    Gibbons C.E.
    European Journal of Trauma, 2006, 32 (5): : 468 - 470
  • [7] FRACTURES AND DISLOCATIONS OF DISTAL CLAVICLE
    HEPPENSTALL, RB
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1975, 6 (02) : 477 - 486
  • [8] Comparative clinical outcomes and radiological images of clavicle hook plate versus Scorpion Plate® for unstable distal clavicle fractures
    Takatori, Naoki
    Uchiyama, Yoshiyasu
    Shimpuku, Eiji
    Imai, Takeshi
    Watanabe, Masahiko
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2025, 30 (02) : 307 - 312
  • [9] Results using the AO hook plate for dislocations of the acromioclavicular joint
    Koukakis, Athanasios
    Manouras, Andreas
    Apostolou, Constantinos D.
    Lagoudianakis, Emmanuel
    Papadima, Artemisia
    Triantafillou, Christos
    Korres, Dimitrios
    Allen, Paul W.
    Amini, Alexander
    EXPERT REVIEW OF MEDICAL DEVICES, 2008, 5 (05) : 567 - 572
  • [10] Biomechanical analysis of clavicle hook plate implantation with different hook angles in the acromioclavicular joint
    Hung, Li-Kun
    Su, Kuo-Chih
    Lu, Wen-Hsien
    Lee, Cheng-Hung
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (08) : 1663 - 1669