Measurement of lung density by photon transmission for monitoring intravascular and extravascular fluid volume changes in the lungs

被引:1
|
作者
Bergström, P [1 ]
Jacobsson, L
Lomsky, M
机构
[1] Sahlgrenska Univ Hosp Sahlgrenska, Dept Radiat Phys, SE-41345 Gothenburg, Sweden
[2] Sahlgrenska Univ Hosp Sahlgrenska, Dept Clin Physiol, SE-41345 Gothenburg, Sweden
来源
CLINICAL PHYSIOLOGY | 1999年 / 19卷 / 06期
关键词
gamma camera; left ventricular heart function; lung blood pool; lung density; transmission;
D O I
10.1046/j.1365-2281.1999.00198.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Left ventricular (LV) heart failure increases pulmonary blood volume (PBV) and interstitial fluid volume. Continuous measurements of lung density may be a simple non-invasive method for monitoring of the LV function as the lung density should reflect the changes in the PBV and extravascular lung water. The purpose of the study was to optimize transmission measurements of the lung with a gamma camera and a planar source. Another aim was to assess the possibility of transmission monitoring in normal subjects at rest and during exercise and to compare the results with simultaneous measurements of PBV changes. Transmission measurements were made in a water-filled phantom containing lungs of different density. A gamma camera and a planar Co-57 source were used. The coefficient of variation in density determination owing to counting statistics in a lung area was calculated for different energy windows, acquisition times and collimation. Dynamic measurements in normal subjects were carried out in a sitting and a supine position at rest and during exercise. Pulmonary blood volume was monitored simultaneously using Tc-99m-labelled red blood cells and the registered blood pool activity was corrected for attenuation. Highest precision in relative density determination was obtained with large energy window and uncollimated source. A precision of 1.0% was obtained with 1 min measuring time. About 10% change in transmission corresponding to a 15% change in density was observed during exercise. Changes in blood pool and lung density covariated. We conclude that lung density changes can be monitored with a high degree of statistical precision in a few minutes and with a low radiation dose of radiation using a gamma camera and a planar source.
引用
收藏
页码:519 / 526
页数:8
相关论文
共 50 条
  • [1] Extravascular lung water and intravascular volume monitoring
    Roberti, A
    Girardis, M
    [J]. INTENSIVE CARE MEDICINE, 2002, 28 (12) : 1832 - 1832
  • [2] Extravascular lung water and intravascular volume monitoring
    Andrea Roberti
    Massimo Girardis
    [J]. Intensive Care Medicine, 2002, 28 : 1832 - 1832
  • [3] Quantitative measurement of extravascular lung density and pulmonary blood volume using blood volume SPECT with transmission imaging
    Wong, KL
    Araujo, LI
    McClellan, JR
    Maffei, J
    Denofrio, D
    Loh, E
    [J]. CIRCULATION, 1997, 96 (08) : 4129 - 4129
  • [4] Intravascular volume monitoring and extravascular lung water in septic patients with pulmonary edema
    Sandrine Boussat
    Thierry Jacques
    Bruno Levy
    Evelyne Laurent
    Antoine Gache
    Gilles Capellier
    Alain Neidhardt
    [J]. Intensive Care Medicine, 2002, 28 : 712 - 718
  • [5] Intravascular volume monitoring and extravascular lung water in septic patients with pulmonary edema
    Boussat, S
    Jacques, T
    Levy, B
    Laurent, E
    Gache, A
    Capellier, G
    Neidhardt, A
    [J]. INTENSIVE CARE MEDICINE, 2002, 28 (06) : 712 - 718
  • [6] QUANTITATIVE DISTRIBUTIONS OF INTRAVASCULAR, TOTAL LUNG WATER AND EXTRAVASCULAR LUNG WATER VOLUME IN ISOLATED PERFUSED DOG LUNGS
    AHLUWALIA, B
    KANAREK, D
    LATTY, A
    JAVHERI, S
    SHANNON, DC
    KAZEMI, H
    [J]. FEDERATION PROCEEDINGS, 1977, 36 (03) : 536 - 536
  • [7] Relationship of extravascular lung water and intravascular blood volume to acute lung injury
    Innes, R
    Rowe, D
    Steel, A
    [J]. CRITICAL CARE MEDICINE, 2001, 29 (12) : A27 - A27
  • [8] TRANSVASCULAR FLUID FILTRATION AND INTRAVASCULAR VOLUME IN ISOLATED PERFUSED LUNGS
    NICOLAYSEN, G
    AARSETH, P
    WAALER, BA
    [J]. ACTA PHYSIOLOGICA SCANDINAVICA, 1976, 96 (03): : A25 - A26
  • [9] Monitoring intracellular, interstitial, and intravascular volume changes during fluid management procedures
    Leslie D. Montgomery
    Wayne A. Gerth
    Richard W. Montgomery
    Susie Q. Lew
    Michael M. Klein
    Julian M. Stewart
    Manuel T. Velasquez
    [J]. Medical & Biological Engineering & Computing, 2013, 51 : 1167 - 1175
  • [10] Monitoring intracellular, interstitial, and intravascular volume changes during fluid management procedures
    Montgomery, Leslie D.
    Gerth, Wayne A.
    Montgomery, Richard W.
    Lew, Susie Q.
    Klein, Michael M.
    Stewart, Julian M.
    Velasquez, Manuel T.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2013, 51 (10) : 1167 - 1175