A novel ZVS high voltage power supply for micro-channel plate photomultiplier tubes

被引:3
|
作者
Pei, Chengquan [1 ]
Tian, Jinshou [2 ]
Liu, Zhen [1 ]
Qin, Hong [3 ]
Wu, Shengli [1 ]
机构
[1] Xi An Jiao Tong Univ, Key Lab Phys Elect & Devices, Minist Educ, Xian 710049, Peoples R China
[2] Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 710119, Peoples R China
[3] Xian Univ Sci & Technol, Sch Comp Sci & Technol, Xian 710054, Peoples R China
关键词
Micro-channel plate photomultiplier tubes; Resonant converter; Push-pull Zero voltage switching; ZERO-VOLTAGE; CONVERTER;
D O I
10.1016/j.nima.2017.01.044
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A novel resonant high voltage power supply (HVPS) with zero voltage switching (ZVS), to reduce the voltage stress on switching devices and improve conversion efficiency, is proposed. The proposed HVPS includes a drive circuit, a transformer, several voltage multiplying circuits, and a regulator circuit. The HVPS contains several secondary windings that can be precisely regulated. The proposed HVPS performed better than the traditional resistor voltage divider, which requires replacing matching resistors resulting in resistor dispersibility in the Micro-Channel Plate (MCP). The equivalent circuit of the proposed HVPS was established and the operational principle analyzed. The entire switching element can achieve ZVS, which was validated by a simulation and experiments. The properties of this HVPS were tested including minimum power loss (240 mW), maximum power loss (1 W) and conversion efficiency (85%). The results of this research are that the proposed HVPS was suitable for driving the micro-channel plate photomultiplier tube (MCP-PMT). It was therefore adopted to test the MCP-PMT, which will be used in Daya Bay reactor neutrino experiment II in China.
引用
收藏
页码:43 / 49
页数:7
相关论文
共 50 条
  • [1] High Voltage Power Supply with Low Power Consumption for Photomultiplier Tubes
    Cunha, Jose Paulo V. S.
    Begalli, Marcia
    Bellar, Maria D.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1354 - 1357
  • [2] Timing characteritics of a micro-channel plate and fine mesh photomultiplier tubes in a 1 T field
    Kichimi, Hiromichi, 1600, Publ by Elsevier Science Publ BV (North-Holland), Amsterdam, Netherlands (A325):
  • [3] Large-area micro-channel plate photomultiplier tube
    North Night Vision Technology Co., Ltd, Nanjing
    211100, China
    不详
    100049, China
    不详
    710119, China
    Hongwai yu Jiguang Gongcheng Infrared Laser Eng., 1600, 4
  • [4] High Voltage Power Supply With High Output Current and Low Power Consumption for Photomultiplier Tubes
    Cunha, Jose Paulo V. S.
    Begalli, Marcia
    Bellar, Maria Dias
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (02) : 281 - 288
  • [5] An Application of Micro-channel Plate Photomultiplier Tube to Positron Emission Tomography
    Kim, H.
    Chen, C. -T.
    Frisch, H.
    Tang, F.
    Kao, C. -M.
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 2012, 37 : 1480 - 1487
  • [6] Performance and lifetime of micro-channel plate tubes for the TORCH detector
    Gys, T.
    Garcia, L. Castillo
    Fopma, J.
    Forty, R.
    Frei, C.
    Gao, R.
    Harnew, N.
    Keri, T.
    Piedigrossi, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 766 : 171 - 172
  • [7] Timing measurements of a micro-channel plate photomultiplier incorporating a novel equal-time anode structure
    Byrum, Karen
    Anderson, John
    Drake, Gary
    Ertley, Camden
    Frisch, Henry
    Sanders, Harold
    Tang, Fukun
    Va'vra, Jerry
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 80 - 82
  • [8] A Disc-DIRC Cherenkov Detector with High Resolution Micro Channel Plate Photomultiplier Tubes
    Rieke, J.
    Dueren, M.
    Etzelmueller, E.
    Foehl, K.
    Hayrapetyan, A.
    Kroeck, B.
    Merle, O.
    Dzhygadlo, R.
    Gerhardt, A.
    Goetzen, K.
    Kahey, G.
    Krebs, M.
    Kumawat, H.
    Lehmann, D.
    Patsyuk, M.
    Peters, K.
    Schepers, G.
    Schmitt, L.
    Schwarz, C.
    Schwiening, J.
    Traxler, M.
    Zuehlsdorf, M.
    Dodokhov, V. Kh
    Uhlig, F.
    Britting, A.
    Eyrich, W.
    Lehmann, A.
    Cowie, E.
    Keri, T.
    Montgomery, R.
    Achenbach, P.
    Cardinali, M.
    Hoek, M.
    Lauth, W.
    Schlimme, S.
    Sfienti, C.
    Thiel, M.
    Buehler, P.
    Gruber, L.
    Marton, J.
    Suzuki, K.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [9] Development of the micro-channel plate photomultiplier for the Belle II time-of-propagation counter
    Hirose, Shigeki
    Iijima, Toru
    Inami, Kenji
    Furumura, Daiki
    Hayakawa, Tomokatsu
    Kato, Yuji
    Matsuoka, Kodai
    Mizuno, Ryo
    Sato, Yutaro
    Suzuki, Kazuhito
    Yonekura, Takuya
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 787 : 293 - 296
  • [10] COMPUTER-ANALYSIS OF THE TIMING PROPERTIES IN MICRO CHANNEL PLATE PHOTOMULTIPLIER TUBES
    ITO, M
    KUME, H
    OBA, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) : 408 - 412