Nonlinear Cyclic Behaviour of Precast Concrete Frame Sub-Assemblies With "Dry" End Plate Connection

被引:52
|
作者
Aninthaneni, P. K. [1 ]
Dhakal, R. P. [1 ]
Marshall, J. [2 ]
Bothara, J. [3 ]
机构
[1] Univ Canterbury, Dept Civil & Nat Resources Engn, Christchurch, New Zealand
[2] Busck Prestressed Concrete, Christchurch, New Zealand
[3] Miyamoto Int NZ Ltd, Auckland, New Zealand
关键词
Precast concrete; Dry; End plate; Demountable; Beam-column connection; Emulative; Jointed frame system; COLUMN DOWEL CONNECTIONS; PLASTIC HINGE LENGTH; STRENGTH; MEMBERS; MODEL;
D O I
10.1016/j.istruc.2018.03.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents in detail the design characteristics of dry and demountable end plate beam-column connection for an emulative jointed precast concrete frame system whose structural performance is similar to that of a wet jointed/monolithic concrete frame system. The load transfer mechanism as well as an analytical framework to calculate the ultimate capacity of the end plate connection is explained in detail. The hysteretic behaviour of the frame sub-assemblies with the end plate connection is experimentally evaluated under quasi-static cyclic loading. Accuracy of the developed analytical equations is assessed by comparing the predicted nominal lateral strength and stiffness with the test results. Also, structural performance of a frame sub-assembly with the end plate connection is evaluated by comparing the experimentally obtained hysteretic plot with the hysteretic plots of the frame systems with wet joints or ductile connectors reported in literature. Nonlinear cyclic behaviour of the tested frame sub-assemblies is numerically simulated by using the "pivot" and "IMK peak oriented" hysteresis models, and the accuracy of the developed numerical models is evaluated by comparing with the test results. The importance of a correct moment-rotation backbone curve to capture the capping point is highlighted through different case studies. Based on the evidences reported herein, it is concluded that the proposed end plate beam-column connection acts as a rigid moment connection, and a precast concrete frame system developed using end plate beam-column connections is demountable and it is able to structurally perform at par with (if not better than) a precast concrete frame system with wet joints.
引用
收藏
页码:124 / 136
页数:13
相关论文
共 15 条
  • [1] Experimental investigation of “dry” jointed precast concrete frame sub-assemblies with steel angle and tube connections
    P. K. Aninthaneni
    R. P. Dhakal
    J. Marshall
    J. Bothara
    Bulletin of Earthquake Engineering, 2020, 18 : 3659 - 3681
  • [2] Experimental investigation of "dry" jointed precast concrete frame sub-assemblies with steel angle and tube connections
    Aninthaneni, P. K.
    Dhakal, R. P.
    Marshall, J.
    Bothara, J.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2020, 18 (08) : 3659 - 3681
  • [3] Analytical and numerical investigation of "dry" jointed precast concrete frame sub-assemblies with steel angle and tube connections
    Aninthaneni, P. K.
    Dhakal, R. P.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2019, 17 (09) : 4961 - 4985
  • [4] Analytical and numerical investigation of “dry” jointed precast concrete frame sub-assemblies with steel angle and tube connections
    P. K. Aninthaneni
    R. P. Dhakal
    Bulletin of Earthquake Engineering, 2019, 17 : 4961 - 4985
  • [5] Flexural behavior of precast concrete wall - steel shoe composite assemblies with dry connection
    Wu, Xiangguo
    Xia, Xinlei
    Kang, Thomas H-K
    Han, Jingcheng
    Kim, Chang-Soo
    STEEL AND COMPOSITE STRUCTURES, 2018, 29 (04): : 545 - 555
  • [6] Cyclic Loading Test for Reinforced-Concrete-Emulated Beam-Column Connection of Precast Concrete Moment Frame
    Im, Hyeong-Ju
    Park, Hong-Gun
    Eom, Tae-Sung
    ACI STRUCTURAL JOURNAL, 2013, 110 (01) : 115 - 125
  • [7] Dry-jointed precast concrete frame on rocking or fixed footings under cyclic lateral loading
    Stathas, Nikolaos
    Palios, Xenofontas
    Strepelias, Elias
    Fardis, Michael N.
    Bousias, Stathis N.
    Sarkis, Ana
    BULLETIN OF EARTHQUAKE ENGINEERING, 2017, 15 (11) : 4915 - 4938
  • [8] Dry-jointed precast concrete frame on rocking or fixed footings under cyclic lateral loading
    Nikolaos Stathas
    Xenofontas Palios
    Elias Strepelias
    Michael N. Fardis
    Stathis N. Bousias
    Ana Sarkis
    Bulletin of Earthquake Engineering, 2017, 15 : 4915 - 4938
  • [9] Design and cyclic testing of a gusset plate connection for precast concrete buckling-restrained braced frames
    Kessler, Hannah D.
    Conway, Kaitlynn M.
    Redmond, Laura M.
    Pataky, Garrett J.
    PCI JOURNAL, 2023, 68 (02): : 30 - 51
  • [10] Cyclic behaviour of friction energy dissipation connection systems with precast concrete cladding panel: Experimental and numerical studies
    Sui, Weining
    Zhu, Lin
    Yang, Haitao
    Wang, Zhanfei
    Ma, Yong
    JOURNAL OF BUILDING ENGINEERING, 2024, 98