Pressurized ion chamber for low energy radiation monitoring

被引:2
|
作者
Prasad, KR
Balagi, V
Dighe, PM
Alex, M
Karpagam, R
机构
[1] Electronics Division, Bhabha Atomic Research Centre
关键词
D O I
10.1016/S1350-4487(97)00019-X
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Ion chambers that can respond to gamma energies as low as 35 keV have been developed for environmental and area monitoring for low energy X-ray background a: the rotating anode X-ray generator facility and other accelerators at CAT, Indore. They are expected to measure exposure levels ranging from 10 mu r/h to 100 mr/h. These chambers have an all-welded aluminium construction and pressurized nitrogen filling. Explosion welded SS-AI clad material has been used for the welding of SS-to-alumina insulators. Out of the two ion chambers developed. the environmental ion chamber has a 25 1 sensitive volume filled at 85 psi and detects radiation exposure levels from 10 mu r/h to 10 mr/h. The 800 cc area monitor ion chamber filled at 120 psi can be used from 10 mr/h to 10 r/h with a portable survey instrument. These chambers have an energy response between 35 keV and 1.25 MeV that is uniform within +/-9%. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:593 / 598
页数:6
相关论文
共 50 条
  • [1] A PRESSURIZED ION-CHAMBER MONITORING-SYSTEM FOR ENVIRONMENTAL RADIATION MEASUREMENTS UTILIZING A WIDE-RANGE TEMPERATURE-COMPENSATED ELECTROMETER
    VANSTEVENINCK, W
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1080 - 1085
  • [2] Development of A handheld pressurized ionization chamber for gamma monitoring
    Biyik, Recep
    Alacayir, Osman
    Yalcin, Tamer
    Tuna, Tuncay
    RADIATION MEASUREMENTS, 2025, 181
  • [3] Performance evaluation of a homemade extrapolation chamber in low energy radiation field
    Liu, Chuanfeng
    Song, Mingzhe
    Liu, Yuntao
    Li, Dehong
    Hang, Zhongbin
    Zhang, Jian
    Wang, Hongyu
    Wei, Kexin
    Huang, Jianwei
    VACUUM, 2022, 202
  • [4] Extrapolation chamber response in low-energy x radiation standard beams
    Dias, SK
    Caldas, LVE
    JOURNAL OF APPLIED PHYSICS, 2001, 89 (01) : 669 - 671
  • [5] Low Threshold-Energy Ionization Chamber System for Monitoring in Proton Therapy
    Potashev S.I.
    Akulinichev S.V.
    Burmistrov Y.M.
    Drachev A.I.
    Bulletin of the Russian Academy of Sciences: Physics, 2021, 85 (05) : 496 - 500
  • [6] PRESSURIZED DISCHARGE CHAMBER
    KAJIKAWA, R
    KOBAYAKAWA, H
    MASAIKE, A
    OHASHI, Y
    OKADA, A
    NUCLEAR INSTRUMENTS & METHODS, 1966, 43 (02): : 373 - +
  • [7] Degradation of polyacrylonitrile by low energy ion beam and UV radiation
    Aggour, YA
    Aziz, MS
    POLYMER TESTING, 2000, 19 (03) : 261 - 267
  • [8] OPTICAL RADIATION FROM LOW ENERGY ION SURFACE COLISIONS
    WHITE, CW
    TOLK, NH
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (11): : 1507 - &
  • [9] Development of ion chambers for the measurement of low energy synchrotron radiation
    Mahant, A. K.
    Singh, Sunil Kumar
    Panyam, Vinatha S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 601 (03): : 354 - 357
  • [10] AN ION CHAMBER AND COUNTER FOR RECORDING HLALPHA RADIATION
    DMITRIEV, AB
    KATYUSHI.VV
    SOROKIN, LS
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1965, (04): : 799 - &