Clinical usability, reliability, and repeatability of noncontact scanners in measuring residual limb volume in persons with transtibial amputation

被引:2
|
作者
Kofman, Rianne [1 ,2 ]
Winter, Raoul E. [2 ,3 ]
Emmelot, Cornelis H. [3 ]
Geertzen, Jan H. B. [4 ]
Dijkstra, Pieter U. [4 ]
机构
[1] Treant Zorggrp Hosp, Dept Rehabil Med, Emmen, Netherlands
[2] Vogellanden Rehabil Ctr, Zwolle, Netherlands
[3] Isala Hosp, Zwolle, Netherlands
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Rehabil Med, Groningen, Netherlands
关键词
amputation; CAD/CAM system; transtibial; volume measurement; AMPUTEES;
D O I
10.1097/PXR.0000000000000087
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: In previous studies, noncontact 3D scanners were found to be the most reliable in measuring volume of the residual limb after a transtibial amputation (TTA). Meanwhile newly developed noncontact scanners became available to measure residual limb volume after TTA but should be tested for clinical usability and reliability. Objective: To determine the clinical usability, reliability, and repeatability of noncontact scanners in measuring residual limb volume in persons with a TTA. Study design: Original research report; repeated measurements. Methods: Three noncontact scanners (Rodin4D, Omega Tracer, and Biosculptor) were used to measure the residual limb volume on two occasions by two observers in 30 persons with an unilateral or bilateral TTA. Clinical usability was assessed as scores of the PostStudy System Usability Questionnaire, participant satisfaction (0-10 scale), and time to take the measurement. Results: The usability score of the Omega Scanner 3D(123.4) and Rodin4D (121.3) was significantly better comparedwith the Biosculptor (117.8). Participant experience was equal for all. The residual variance was 8.4%, where participant and scanning system explained most of the error variance (80.7%). Repeatability coefficients of the systems were 16.5 cc (Omega Scanner 3D), 26.4 cc (Rodin4D), and 32.8 cc (Biosculptor). The time to performthe measurements was significantly longer (+80 seconds) for the Omega Scanner 3D. Conclusions For measuring residual limb volume in TT amputees, Omega software (state version 12.2) combined with the Rodin4D scanner was more usable and reliable than the Rodin 4D or Biosculptor systems, when operated by staff with limited experience and training.
引用
收藏
页码:164 / 169
页数:6
相关论文
共 11 条
  • [1] Measurement properties and usability of non-contact scanners for measuring transtibial residual limb volume
    Kofman, Rianne
    Beekman, Anna M.
    Emmelot, Cornelis H.
    Geertzen, Jan H. B.
    Dijkstra, Pieter U.
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2018, 42 (03) : 280 - 287
  • [2] Reduction of residual limb volume in people with transtibial amputation
    Tantua, Audrey T.
    Geertzen, Jan H. B.
    van den Dungen, Jan J. A. M.
    Breek, Jan-Kees C.
    Dijkstra, Pieter U.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2014, 51 (07): : 1119 - 1126
  • [3] Reliability and validity of the iSense optical scanner for measuring volume of transtibial residual limb models
    Armitage, Lucy
    Kwah, Li Khim
    Kark, Lauren
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2019, 43 (02) : 213 - 220
  • [4] The Overlay, a New Solution for Volume Variations in the Residual Limb for Individuals with a Transtibial Amputation
    Badaire, Pierre
    Robert, Maxime T.
    Turcot, Katia
    SENSORS, 2024, 24 (14)
  • [5] Measuring residual limb health in persons with upper limb amputation: Modifications of the Prosthetic Evaluation Questionnaire residual limb health scale
    Resnik, Linda
    Borgia, Matthew
    Clark, Melissa A.
    Ni, Pengsheng
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2023, 47 (05) : 544 - 551
  • [6] Socket size adjustments in people with transtibial amputation: Effects on residual limb fluid volume and limb-socket distance
    McLean, Jake B.
    Redd, Christian B.
    Larsen, Brian G.
    Garbini, Joseph L.
    Brzostowski, Jacob T.
    Hafner, Brian J.
    Sanders, Joan E.
    CLINICAL BIOMECHANICS, 2019, 63 (161-171) : 161 - 171
  • [7] Using vacuum-assisted suspension to manage residual limb wounds in persons with transtibial amputation: A case series
    Hoskins, Robert D.
    Sutton, Erin E.
    Kinor, Deborah
    Schaeffer, Julia M.
    Fatone, Stefania
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2014, 38 (01) : 68 - 74
  • [8] How do sock ply changes affect residual-limb fluid volume in people with transtibial amputation?
    Sanders, Joan E.
    Harrison, Daniel S.
    Allyn, Katheryn J.
    Myers, Timothy R.
    Ciol, Marcia A.
    Tsai, Elaine C.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2012, 49 (02): : 241 - 256
  • [9] Consistency, precision, and accuracy of optical and electromagnetic shape-capturing systems for digital measurement of residual-limb anthropometrics of persons with transtibial amputation
    Geil, Mark D.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2007, 44 (04): : 515 - 524
  • [10] Effectiveness of elevated vacuum and suction prosthetic suspension systems in managing daily residual limb fluid volume change in people with transtibial amputation
    Youngblood, Robert T.
    Brzostowski, Jacob T.
    Hafner, Brian J.
    Czerniecki, Joseph M.
    Allyn, Katheryn J.
    Foster, Richard L.
    Sanders, Joan E.
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2020, 44 (03) : 155 - 163