Point-of-care Optical Tool to Detect Early Stage of Hemorrhage and Shock

被引:1
|
作者
Gurjar, Rajan S. [1 ]
Riccardi, Suzannah L. [1 ]
Johnson, Blair D. [2 ]
Johnson, Christopher P. [2 ]
Paradis, Norman A. [3 ]
Joyner, Michael J. [2 ]
Wolf, David E. [1 ]
机构
[1] Radiat Monitoring Devices Inc, 44 Hunt St, Watertown, MA 02172 USA
[2] Mayo Clin, Dept Anesthesiol, Rochester, MN USA
[3] Dartmouth Hitchcock Med Ctr, Dept Emergency Med, Dartmouth, NS, Canada
关键词
Point-of-Care; Hemorrhage; Diffuse Correlation; DIFFUSE CORRELATION SPECTROSCOPY; BLOOD-FLOW; HEMODYNAMICS; TRAUMA;
D O I
10.1117/12.2040267
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
There is a critical unmet clinical need for a device that can monitor and predict the onset of shock: hemorrhagic shock or bleeding to death, septic shock or systemic infection, and cardiogenic shock or blood flow and tissue oxygenation impairment due to heart attack. Together these represent 141 M patients per year. We have developed a monitor for shock based on measuring blood flow in peripheral (skin) capillary beds using diffuse correlation spectroscopy, a form of dynamic light scattering, and have demonstrated proof-of-principle both in pigs and humans. Our results show that skin blood flow measurement, either alone or in conjunction with other hemodynamic properties such as heart rate variability, pulse pressure variability, and tissue oxygenation, can meet this unmet need in a small self-contained patch-like device in conjunction with a hand-held processing unit. In this paper we describe and discuss the experimental work and the multivariate statistical analysis performed to demonstrate proof-of-principle of the concept.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Evaluation of the Active Melioidosis Detect™ test as a point-of-care tool for the early diagnosis of melioidosis: a comparison with culture in Laos
    Rizzi, Maria Chiara
    Rattanavong, Sayaphet
    Bouthasavong, Latsaniphone
    Seubsanith, Amphayvanh
    Vongsouvath, Manivanh
    Davong, Viengmon
    De Silvestri, Annalisa
    Manciulli, Tommaso
    Newton, Paul N.
    Dance, David A. B.
    TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2019, 113 (12) : 757 - 763
  • [2] Point-of-Care Ultrasound for Pediatric Shock
    Park, Daniel B.
    Presley, Bradley C.
    Cook, Thomas
    Hayden, Geoffrey E.
    PEDIATRIC EMERGENCY CARE, 2015, 31 (08) : 591 - 598
  • [3] Using point-of-care ultrasound: Shock
    Breunig, Michael
    Kashiwagi, Deanne
    JAAPA-JOURNAL OF THE AMERICAN ACADEMY OF PHYSICIAN ASSISTANTS, 2019, 32 (08): : 43 - 48
  • [4] POINT-OF-CARE CRANIAL ULTRASOUND B MODE CAN DETECT INTRACRANIAL HEMORRHAGE WITH HIGH FIDELITY
    Levi, John
    Sarwal, Aarti
    CRITICAL CARE MEDICINE, 2021, 49 (01) : 353 - 353
  • [5] Point-of-Care Ultrasound in Sepsis and Septic Shock
    Kaselitz, Timothy B.
    Seymour, Christopher W.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2025,
  • [6] Point-of-care prothrombin time testing as an early predictor of severe post partum hemorrhage
    Ducloy-Bouthors, Anne-Sophie
    Duhamel, Alain
    Pilla, Clotaire
    Barre, Catherine
    Bauters, Anne
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 : 192 - 193
  • [7] Point-of-care prothrombin time testing as an early predictor of severe post partum hemorrhage
    Susen, S.
    Bauters, A.
    Pilla, C.
    Barre, C.
    Tournoys, A.
    Duhamel, A.
    Depret-Mosser, S.
    Jude, B.
    Ducloy, A-S
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 943 - 943
  • [8] Point-of-care impedimetric aptasensor to detect the luteinizing hormone
    Kumar, Pankaj
    Anitha, Arumugam
    Das, Ankita
    Deepalakshmi, Govindarajan
    Suman, Pankaj
    MICROCHIMICA ACTA, 2024, 191 (02)
  • [9] Point-of-care impedimetric aptasensor to detect the luteinizing hormone
    Pankaj Kumar
    Arumugam Anitha
    Ankita Das
    Govindarajan Deepalakshmi
    Pankaj Suman
    Microchimica Acta, 2024, 191
  • [10] A perspective on point-of-care tests to detect eosinophilic bronchitis
    Nair, Parameswaran
    Zhang, Qiang
    Brennan, John D.