Performance analysis of a dielectric based 3D building integrated concentrating photovoltaic system

被引:87
|
作者
Baig, Hasan [1 ]
Sellami, Nazmi [1 ]
Chemisana, Daniel [2 ]
Rosell, Joan [2 ]
Mallick, Tapas K. [1 ]
机构
[1] Univ Exeter, Environm & Sustainabil Inst, Penryn TR10 9FE, Cornwall, England
[2] Univ Lleida, Lleida, Spain
基金
英国工程与自然科学研究理事会;
关键词
3DCCPC; Non-uniform; CPV; BiCPV; CPC; COMPOUND PARABOLIC CONCENTRATOR; SOLAR-CELLS; MODULES;
D O I
10.1016/j.solener.2014.03.002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The use of concentrating photovoltaic systems (CPV) in building integration has spurred towards the development of newer products, which have the potential to offer the convenience of pleasing architecture and day lighting along with simultaneous production of clean energy. This paper addresses the energy transformations and the expected energy output of a low concentrating photovoltaic system designed to have a geometric concentration of 3.6 x. The optical element used is a three dimensional Cross Compound Concentrator (3DCCPC) made from clear polyurethane material. Small sized silicon solar cells based on the Laser Grooved Buried Contact (LGBC) technology having an absorber area of 1 cm(2) are utilised in the system. Both experimental and numerical analyses are performed confirming the optical, electrical and thermal performance of the system. While performing the optical analysis the concentrator was found to have a maximum optical efficiency of 73.4%. A maximum power ratio of 2.67 was observed when comparing the electrical output of the concentrator unit with a non-concentrating counterpart. The effects of non-uniformity caused by the use of the concentrator are analysed. The non-uniformity of flux distribution showed an average drop of 2.2% in the I-sc values which is again reflected in the overall power output. Manufacturing defects like the cell and concentrator misalignments are addressed and their impact on the overall performance are verified by numerical simulations. The operating temperature of the solar cells was found to have a parasitic effect on the overall performance of the system. A maximum temperature of 332 K was observed in the solar cell at 0 degrees incidence and a incoming radiation of 1000 W/m(2) which brings down the overall power production by 14.6%. Finally, the expected system output over a given time period is presented showing the strengths and weakness while employing such a system. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:525 / 540
页数:16
相关论文
共 50 条
  • [1] Dielectric-based 3D building-integrated concentrating photovoltaic modules: An environmental life-cycle assessment
    Lamnatou, Chr.
    Baig, H.
    Chemisana, D.
    Mallick, T. K.
    ENERGY AND BUILDINGS, 2017, 138 : 514 - 525
  • [2] Performance analysis of a reflective 3D crossed compound parabolic concentrating photovoltaic system for building facade integration
    Mammo, Eliyas Debebe
    Sellami, Nazmi
    Mallick, Tapas Kumar
    PROGRESS IN PHOTOVOLTAICS, 2013, 21 (05): : 1095 - 1103
  • [3] Performance modeling and testing of a Building Integrated Concentrating Photovoltaic (BICPV) system
    Baig, Hasan
    Sellami, Nazmi
    Mallick, Tapas K.
    SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2015, 134 : 29 - 44
  • [4] Performance enhancement of a Building-Integrated Concentrating Photovoltaic system using phase change material
    Sharma, Shivangi
    Tahir, Asif
    Reddy, K. S.
    Mallick, Tapas K.
    SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2016, 149 : 29 - 39
  • [5] Performance analysis of building integrated with photovoltaic thermal system and traditional rooftop photovoltaic system
    Mishra, Gourav Kumar
    Bhatti, T. S.
    Tiwari, G. N.
    PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON TECHNOLOGICAL ADVANCEMENTS IN POWER AND ENERGY (TAP ENERGY): EXPLORING ENERGY SOLUTIONS FOR AN INTELLIGENT POWER GRID, 2017,
  • [6] Overall detail comparison for a building integrated concentrating photovoltaic/daylighting system
    Xuan, Qingdong
    Li, Guiqiang
    Lu, Yashun
    Zhao, Bin
    Zhao, Xudong
    Su, Yuehong
    Ji, Jie
    Pei, Gang
    ENERGY AND BUILDINGS, 2019, 199 : 415 - 426
  • [7] Comprehensive analysis of electrical-optical performance and application potential for 3D concentrating photovoltaic window
    Zhang, Wei
    Li, Jianhui
    Xie, Lingzhi
    Hao, Xia
    Mallick, Tapas
    Wu, Yupeng
    Baig, Hasan
    Shanks, Katie
    Sun, Yanyi
    Yan, Xiaoyu
    Tian, Hao
    Li, Zihao
    RENEWABLE ENERGY, 2022, 189 : 369 - 382
  • [8] Life cycle energy analysis and embodied carbon of a linear dielectric-based concentrating photovoltaic appropriate for building-integrated applications
    Lamnatou, Chr
    Baig, H.
    Chemisana, D.
    Mallick, T. K.
    ENERGY AND BUILDINGS, 2015, 107 : 366 - 375
  • [9] Performance of photovoltaic/thermal solar system in building integrated photovoltaic
    Wei, Chenguang
    Bao, Yiwang
    Deng, Xiaoying
    Liu, Zhengquan
    Wu, Xiaoli
    Kuei Suan Jen Hsueh Pao/Journal of the Chinese Ceramic Society, 2013, 41 (02): : 149 - 152
  • [10] Design and performance analysis of a novel office building integrated photovoltaic system
    Wang, Gang
    Cao, Fan
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 10964 - 10979