Symptomatic spontaneous intracranial carotid artery dissection treated with a self-expanding intracranial nitinol stent: a case report

被引:12
|
作者
Surdell, Daniel L. [1 ]
Bernstein, Richard A. [2 ]
Hage, Ziad A. [1 ]
Batjer, H. Hunt [1 ]
Bendok, Bernard R. [1 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Neurol Soc, Chicago, IL 60611 USA
[2] Northwestern Univ, Feinberg Sch Med, Dept Neurol, Chicago, IL 60611 USA
来源
SURGICAL NEUROLOGY | 2009年 / 71卷 / 05期
关键词
Intracranial dissection; Intracranial stent; Spontaneous dissection; FOLLOW-UP; ENDOVASCULAR TREATMENT; PLACEMENT; ANGIOPLASTY; ANEURYSMS; ANGIOGRAPHY; DEPLOYMENT; INJURIES; COILS;
D O I
10.1016/j.surneu.2007.11.021
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Although extracranial carotid dissection with stroke is common, intracranial dissection with stroke is rare. Stenting has been used to treat extracranial carotid dissections. Intracranially, however, it is only recently that stents have become a feasible option for this disease. We present a case of a spontaneous intracranial CAD with progressive symptoms despite medical management treated with a self-expanding intracranial micronitinol stent. Case Description: A 47-year-old, right-handed woman presented to the emergency department after noticing left-sided face and arm weakness and numbness, along with slurred speech. The patient was started on aspirin 325 mg/d orally and lovenox 40 mg/d subcutaneously. On hospital day 2, the patient was noted to have repeated episodes of weakness and numbness on the left side and MRI evidence of a new stroke. A diagnostic cerebral angiogram from a selective right internal carotid injection revealed a flow-limiting stenosis secondary to a dissection of the supraclinoid internal carotid artery with severe flow limitation to the hemisphere. Endovascular management was decided on, and a Neuroform stent measuring 4.5 x 20 mm (Boston Scientific Corporation, Natick, Mass) was deployed across the dissection with significant improvement of flow to that hemisphere on the poststent angiogram. Conclusions: This case illustrates the successful off-label use of a self-expanding intracranial nitinol stent to treat a symptomatic intracranial internal CAD in the setting of failure of traditional medical management. This is a promising, application of novel endovascular technology. Published by Elsevier Inc.
引用
收藏
页码:604 / 609
页数:6
相关论文
共 50 条
  • [1] SYMPTOMATIC INTRACRANIAL ARTERIAL STENOSIS TREATMENT WITH SELF-EXPANDING NITINOL STENT
    Balboa Arregui, O.
    Pumar Cebreiro, J. M.
    Vazquez Herrero, F.
    Tijerin Bueno, M.
    Magadan Alvarez, V.
    Castineira Mourenza, J. A.
    BRITISH JOURNAL OF SURGERY, 2013, 100 : 6 - 6
  • [2] Emergent Self-Expanding Stent Placement for Acute Intracranial or Extracranial Internal Carotid Artery Dissection with Significant Hemodynamic Insufficiency
    Jeon, P.
    Kim, B. M.
    Kim, D. I.
    Shin, Y. S.
    Kim, K. H.
    Park, S. I.
    Kim, D. J.
    Suh, S. H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (08) : 1529 - 1532
  • [3] Spontaneous improvement of idiopathic intracranial carotid artery dissection: A case report
    Iwamuro, Yasushi
    Nakahara, Ichiro
    Higashi, Toshio
    Watanabe, Yoshihiko
    Matsumoto, Shoji
    Takahashi, Kenji
    Kikuchi, Tetsuhiro
    Ando, Mitsushige
    Takezawa, Masahiro
    NEUROLOGICAL SURGERY, 2008, 36 (07): : 625 - 631
  • [4] Transcranial bypass for spontaneous intracranial carotid artery dissection - A case report
    Park-Matsumoto, YC
    Tazawa, T
    ANGIOLOGY, 2000, 51 (04) : 335 - 340
  • [5] Clinical results of carotid artery stenting with a nitinol self-expanding stent (SMART stent)
    Robert Drescher
    Klaus D. Mathias
    Horst J. Jaeger
    Georg Bockisch
    Eren Demirel
    Martin H. Gissler
    Elke Hauth
    European Radiology, 2002, 12 : 2451 - 2456
  • [6] Clinical results of carotid artery stenting with a nitinol self-expanding stent (SMART stent)
    Drescher, R
    Mathias, KD
    Jaeger, HJ
    Bockisch, G
    Demirel, E
    Gissler, HM
    Hauth, E
    EUROPEAN RADIOLOGY, 2002, 12 (10) : 2451 - 2456
  • [7] Self-Expanding Stent Placement for Anterior Circulation Intracranial Artery Dissection Presenting With Ischemic Symptoms
    Kim, Dong Joon
    Kim, Byung Moon
    Suh, Sang Hyun
    Kim, Dong Ik
    NEUROSURGERY, 2015, 76 (02) : 158 - 164
  • [8] Adjunct use of a self-expanding stent for treatment of intracranial stenosis -: A case report
    Fujimura, N
    Yilmaz, H
    Abdo, G
    Lovblad, KO
    Sztajzel, R
    Rüfenacht, DA
    INTERVENTIONAL NEURORADIOLOGY, 2005, 11 (03) : 269 - 275
  • [10] REVASCULARIZATION OF SYMPTOMATIC SUBACUTE CEREBROVASCULAR OCCLUSIONS WITH A SELF-EXPANDING INTRACRANIAL STENT SYSTEM
    Kelly, Michael E.
    Turner, Raymond D.
    Moskowitz, Shaye I.
    Gonugunta, Vivek R.
    Rasmussen, Peter A.
    Masaryk, Thomas J.
    Fiorella, David
    NEUROSURGERY, 2009, 64 (01) : 72 - 78